[. . . ] INSTALLATION INSTRUCTIONS CAUTION: Turn off power to the electric service or panel and to equipment to be protected before installing any Surge Protection Device. All wiring should be done by a qualified electrician and comply with the National Electric Code and local electric codes. INSTALLATION 1. [. . . ] Failure to comply with this instruction will result in failure of the SPD and void the warranty. If remote monitoring is used, remove the ½" knockout and connect wire leads to the terminal strip located in the monitoring section of the PanelGuard cabinet. Be sure to comply with local and national wiring codes for the voltage of the monitoring circuit. Observe the suggested torque values published by the manufacturer when circuit breakers or separate disconnect devices are used. Close and secure the hinged cover using the locking bolts provided with the cover. Make sure that each Protection Status indicator on the PanelGuard is ON. If not, turn power off and recheck each installation step listed above. If not, turn power off and recheck each installation step listed above. For troubleshooting assistance, call Intermatic at 800-391-4555. 4. 18. 19. WIRING CONFIGURATIONS 120 VAC Single Phase Transformer Secondary Load Center or equipment L1 Black VOLTAGE CONFIGURATION CONFIRMATION MODE VOLTAGE PanelGuard Line to Neutral Line to Ground 120 120 N G White Green Use of Circuit Breakers is optional 120/240 VAC Single (Split) Phase Transformer Secondary VOLTAGE CONFIGURATION CONFIRMATION MODE VOLTAGE Load Center or equipment L1 L2 N G Black Black White Green PanelGuard Line to Line Line to Neutral Line to Ground 240 120 120 Use of Circuit Breakers is optional 120/208 VAC Three Phase WYE Transformer Secondary VOLTAGE CONFIGURATION CONFIRMATION MODE VOLTAGE Load Center or equipment L1 Black L2 Black L3 Black N G White Green PanelGuard Line to Line Line to Neutral Line to Ground 208 120 120 Use of Circuit Breakers is optional 120/240 VAC Three Phase Delta High Leg Delta Transformer Secondary VOLTAGE CONFIGURATION CONFIRMATION MODE VOLTAGE Load Center or equipment L1 Black L2 Red L3 Black N White G Green PanelGuard Line to Line Line to Neutral High Leg to Neutral Line to Ground High Leg to Ground 240 120 208 120 208 Use of Circuit Breakers is optional 277/480 VAC Three Phase WYE Transformer Secondary VOLTAGE CONFIGURATION CONFIRMATION MODE VOLTAGE Load Center or equipment L1 Black L2 Black L3 Black N G White Green PanelGuard Line to Line Line to Neutral Line to Ground 480 277 277 Use of Circuit Breakers is optional 480 VAC Three Phase DELTA Transformer Secondary VOLTAGE CONFIGURATION CONFIRMATION MODE VOLTAGE Load Center or equipment L1 L2 L3 Black Black Black Green PanelGuard Line to Line Line to Ground 480 480 G Use of Circuit Breakers is optional Alarm relay for remote monitoring Violet ­ n/c Brown - c PanelGuard Common - Brown Normally Open - orange Normally Closed - Violet Orange ­ n/o Normal operating condition ­ relay energized Violet ­ n/c Brown - c Orange ­ n/o AC lead connections Alarm relay connections Alarm condition ­ relay not energized Contact your Intermatic Representative or Distributor for information on other hardwired panel Surge Protection Devices. Discover the convenience of integral fusing and the versatility of replaceable protection modules in Intermatic's full line of Surge Protection Devices. TEN YEAR LIMITED PRODUCT WARRANTY For PanelGuardTM2000 SURGE PROTECTION DEVICES (1) What Is Covered By This Limited Warranty Repair or Replacement of Product Intermatic Incorporated ("Intermatic") warrants to the original purchaser only, the Intermatic PanelGuard 2000 Series Surge Protection Device(s) shall be free from defects in material or workmanship for a period of ten years from date of purchase. If the purchaser discovers a defect in material or workmanship, the purchaser must promptly submit a warranty claim. [. . . ] In such states, the limits in this paragraph and in paragraph (3) may not apply. (5) Time Limit for Bringing Suit No action arising out of any claimed breach of warranty may be brought more than one year after the cause of action has accrued. (6) No Other Warranties Unless modified in a writing signed by both parties, this agreement is understood to be the complete and exclusive agreement between the parties, superseding all prior agreements, oral or written, and all other communications between the parties relating to the subject matter of this agreement. No employee of Intermatic or any other party is authorized to make any warranty in additional to those made in this agreement. INTERMATIC INCORPORATED SPRING GROVE ILLINOIS 815-675-2321 Fax: 815-675-2112 http://www. intermatic. com 158EG10423 PDF 8. 02 [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE INTERMATIC IG2403ECD




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual INTERMATIC IG2403ECD will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.