User manual INTERMATIC IG2401LH INSTALLATION

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual INTERMATIC IG2401LH. We hope that this INTERMATIC IG2401LH user guide will be useful to you.


INTERMATIC IG2401LH INSTALLATION: Download the complete user guide (99 Ko)

Manual abstract: user guide INTERMATIC IG2401LHINSTALLATION

Detailed instructions for use are in the User's Guide.

[. . . ] Installation Instructions Commercial / Industrial Hardwired Surge Protection Devices CAUTION: Turn off power to the electric service or panel and to equipment to be protected before installing any Surge Protection Device. All wiring should be done by a qualified electrician and comply with the National Electric Code and local electric codes. [. . . ] Make sure that the phase wires have the correct voltage level between them. Note that for the 240 volt High Leg Delta, the wire for the High Leg is colored RED, and must be connected to the leg that measures approximately 208 volts to neutral and to ground. Failure to comply with this instruction will result in failure of the SPD and void the warranty. Suggested torque values are published by the circuit breaker manufacturer. If not, turn power off and recheck each installation step listed above. For troubleshooting assistance, call Intermatic at 815-675-7000 and ask for Technical Support. 2. 14. INSTALLATION NOTE: The cover of the SPD may be rotated 180 degrees if the device must be installed in an inverted position. Carefully remove the four corner bolts, rotate the cover and reinstall the bolts. Care must be exercised to prevent damage to the wire leads to the LED indicators. WIRING CONFIGURATIONS NOTE: All `LH' units must be installed downstream from breaker or fuse of 400 amps or less capacity. A 30-amp breaker is recommended as a convenient connection point when installing on a breaker panel. 120 volt Single Phase Transformer Secondary Load Center Use 30 amp Breakers CONFIGURATION VOLTAGE L1 Black/Negro Noir Line to Neutral Line to Ground Model IG1201LH 120 120 N G White/Blanco Blanc Green/Verde Vert 120/240 volt Single (Split) Phase Load Center L1 L2 N G Transformer Secondary Use 30 amp Breakers Black/Negro Noir Black/Negro Noir White/Blanco Blanc Green/Verde Vert CONFIGURATION VOLTAGE Line to Line Line to Neutral Line to Ground Model IG2401LH 240 120 120 120/208 volt Three Phase WYE Transformer Secondary Load Center L1 L2 L3 N G Use 30 amp Breakers CONFIGURATION VOLTAGE Black/Negro Noir Black/Negro Noir Black/Negro Noir White/Blanco Blanc Green/Verde Vert Line to Line Line to Neutral Line to Ground Model IG2083LYH 208 120 120 120/240 volt Three Phase Delta High Leg Delta Transformer Secondary Load Center L1 L2 L3 N G Use 30 amp Breakers CONFIGURATION VOLTAGE Black/Negro Noir Red/Rojo Rouge Black/Negro Noir White/Blanco Blanc Green/Verde Vert Model IG2403LDH Line to Line Line to Neutral High Leg to Neutral Line to Ground High Leg to Ground 240 120 208 120 208 277/480 volt Three Phase WYE Transformer Secondary Load Center L1 L2 L3 N G Use 30 amp Breakers CONFIGURATION VOLTAGE Black/Negro Noir Black/Negro Noir Black/Negro Noir White/Blanco Blanc Green/Verde Vert Line to Line Line to Neutral Line to Ground Model IG4803LYH 480 277 277 480 volt Three Phase DELTA Transformer Secondary Load Center L1 L2 L3 G CONFIGURATION VOLTAGE Use 30 amp Breakers Black/Negro Noir Black/Negro Noir Black/Negro Noir Green/Verde Vert Model IG4803LDH Line to Line Line to Ground 480 480 Contact your Intermatic Representative or Distributor for information on other hardwired panel Surge Protection Devices. Discover the convenience of integral fusing and the versatility of replaceable protection modules in Intermatic's full line of Surge Protection Devices. TEN YEAR LIMITED PRODUCT WARRANTY For ® INTERMATIC HARDWIRED SURGE PROTECTION DEVICES (1) What Is Covered By This Limited Warranty Repair or Replacement of Product Intermatic Incorporated ("Intermatic") warrants to the original purchaser only, Intermatic models IG1201LH, IG2401LH, IG2083LYH, IG2403LDH, IG4803LYH, IG4803LDH or IG1201EH, IG2401EH, IG2083YEH, IG2403DEH, IG4803YEH, IG4803DEH Surge Protection Devices (each a "Product") shall be free from defects in material or workmanship for a period of ten years (120 months) from date of purchase or 126 months from date of manufacture. If the purchaser discovers a defect in material or workmanship, the purchaser must promptly submit a warranty claim. [. . . ] IN SUCH STATES, THE LIMITS IN THIS PARAGRAPH AND IN PARAGRAPH (3) MAY NOT APPLY. (5) Time Limit for Bringing Suit No action arising out of any claimed breach of warranty may be brought more than one year after the cause of action has occurred. (6) No Other Warranties Unless modified in writing signed by both parties, this agreement is understood to be the complete and exclusive agreement between the parties, superseding all prior agreements, oral or written, and all other communications between the parties relating to the subject matter of this agreement. No employee of Intermatic or any other party is authorized to make any warranty in addition to those made in this agreement. INTERMATIC INCORPORATED SPRING GROVE ILLINOIS 815-675-2321 Fax: 815-675-2112 http://www. intermatic. com FORM NUMBER 158EG10xxx LH PDF 10. 02 [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE INTERMATIC IG2401LH




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual INTERMATIC IG2401LH will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.