If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual INTERMATIC 158TS11135. We hope that this INTERMATIC 158TS11135 user guide will be useful to you.
Manual abstract: user guide INTERMATIC 158TS11135
Detailed instructions for use are in the User's Guide.
[. . . ] 158TS11135
8/6/04
10:50 AM
Page 1
MODEL: T2005
CALENDER DIAL TIME SWITCH
FOR UP TO 42 TIMING OPERATIONS 0N 7- DAY SCHEDULE
SINGLE POLE DOUBLE THROW SWITCH RATING: 20 AMP. [. . . ] TO PROGRAM TIME SWITCH, Depress tripper(s) into dial at desired time(s) operation(s) is/are required.
·ON TIME: First tripper turns on the load for 135-145 minutes. · OFF TIME: First tripper in raised position turns off the load for 95105 minutes. SET TIME-OF-DAY: Turn dial in CLOCKWISE direction only and align the exact day-of-week and time-of-day on dial (the time when switch is being put in operation) to the "TIME" indicator. OPERATING INSTRUCTIONS TO CONTROL LOADS MANUALLY, Move manual lever (See Figure 1) up. This lever will close normally open circuit and open the normally closed circuit. To return, to automatic control, move lever back to its original position . [. . . ] See step (2) of programming instructions.
INTERMATIC INCORPORATED
SPRING GROVE, ILLINOIS 60081-9698
158TS11135 [. . . ]