User manual INTELLISENSE FG-1015

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual INTELLISENSE FG-1015. We hope that this INTELLISENSE FG-1015 user guide will be useful to you.


INTELLISENSE FG-1015 : Download the complete user guide (380 Ko)

Manual abstract: user guide INTELLISENSE FG-1015

Detailed instructions for use are in the User's Guide.

[. . . ] When wall mounting, mount the unit at a height of at least 6 feet (1. 8 m) to avoid accidental screening if furniture in the room is moved. Curtains, blinds, and other window coverings will absorb energy from breaking glass. In these cases, mount the unit on the window frame behind the window covering, or above the window. Do not mount within 3 feet (0. 9 m) of forced air ducts, sirens, or bells measuring two inches (5 cm) or more in diameter. [. . . ] Generate a flex signal by carefully striking the glass with a cushioned tool. If both the flex and audio are received properly, the red alarm LED on the FG-1015 will light. · · · · · MOUNTING PROCEDURE IMPORTANT: Test the unit in the desired mounting location before drilling mounting holes. To open the sensor, use a screwdriver to push down on the latch at the top of the unit. For mounting the FG-1015 sensor, #6 (M 3. 5) or #8 (M 4) screws are recommended. (Screws are not provided. ) Downloaded from: http://www. guardianalarms. net IMPORTANT: If window coverings are present, close them fully and hold the FG-701 behind the window coverings for testing. NOTE: You can also use the simulator in the MANual mode to test audio alone. The blinking green LED on the unit will flicker when the simulator audio is received correctly. (See the FG-701 Operating Instructions for additional information. ) After testing, exit the Test Mode using the same procedure for activating the Test Mode. The FG-1015 will also automatically exit Test Mode after ten minutes. SPECIFICATIONS Range: 15' (4. 6 M) maximum No minimum range Alarm Relay: Form A 125 mA maximum 25 VDC maximum Alarm Duration: 5 seconds Tamper Switch: Cover tamper 25 mA maximum 24 VDC maximum Power Requirements: 8 - 14 VDC; 25 mA typical at 12 VDC, 35 mA max AC Ripple: 4 Volts peak-to-peak at Nominal 12 VDC Operating Temperature: 32o to 120o F (0o to 49o C) Storage: -4o to 122o F (-20o to 50 o C) RF Immunity: 30 V/m, 10 MHz - 1000 MHz ESD Immunity: 10 kV, Discharges of either polarity to exposed surfaces Dimensions: 3. 86" H x 2. 44" W x 0. 86" D (98 mm x 62 mm x 21. 8 mm) Weight: 3. 2 oz. , (90 g) Packaged Product: 4. 1 oz, (116 g) Approvals/Listings: FCC Verified UL Listed LED Indicators: The two LEDs on the front cover are used to indicate the sensor's operational status. The following table summarizes the LED operation when the LEDs are enabled. Condition Normal, no event Normal, event detected Normal, break detected Power-up self-test Trouble detected Test mode, no alarm Test mode, event detected Test mode, alarm Green LED OFF Flicker OFF ON, one second Flash ON/OFF Flash once per second Flicker Flash once per second Red LED OFF OFF ON ON, one second Flash OFF/ON OFF OFF ON Protected Glass: Minimum size for all types is 11" (28 cm) square; Glass must be framed in the wall of the room or mounted in a barrier of 36" (0. 9 m) minimum width. Thickness Glass Type Plate Tempered Laminated1 Wired Coated2 Sealed Insulating 1 Minimum 3/32" (2. 4 mm) 1/8" (3. 2 mm) 1/8" (3. 2 mm) 1/4" (6. 4 mm) 1/8" (3. 2 mm) 1/8" (3. 2 mm) Maximum 1/4" (6. 4 mm) 1/4" (6. 4 mm) 9/16" (14. 3 mm) 1/4" (6. 4 mm) 1/4" (6. 4 mm) 1/4" (6. 4 mm) APPLICATIONS INFORMATION The FG-1015 is designed to detect framed glass broken by an impact sufficient to make a hole. To minimize the chance of false alarms: · Do not use outside. · Avoid installing in rooms with high-level noise sources, such as air compressors, bells, power tools, etc. , if those sources can be active when the detector can signal an alarm. · Test false alarm immunity by activating any known noise sources in the room. To maximize detection: · Mount the unit on a wall or ceiling directly opposite the glass if possible. The least desirable mounting location is on the same wall as the glass. Do not install beyond the maximum specified range even if testing indicates greater range. · Verify the installation back to the panel to be sure that the protection loop is intact. 1 Laminated and sealed insulating glass types are protected only if both plates of glass are broken. 2 For glass coated on the inner surface with 3M scotchshield type RE35NEARL or Hard Glass Security Film, reduce maximum range to 10 feet (3. 1 m). Accessories: FG-701 Glass-Break Simulator FG-SP1 Spacer Plate - depth 0. 6" (1. 52 cm) FG-SP3 Spacer Plate - depth 0. 3" (0. 76 cm) NOTE: The FG-1015 Glass-Break Detector is designed for primary perimeter security. [. . . ] Always return the unit for repair if there is any indication of trouble, even if the trouble is temporary. LIMITED WARRANTY Seller warrants its products to be in accordance with its own plans and specifications and to be free from defects in materials and workmanship under normal use and service for 18 months from the date stamp control on the product; or for products not having an IntelliSense date stamp, for 12 months from the date of original purchase, unless the installation instructions or catalogue sets forth a shorter period, in which case the shorter period shall apply. Seller's obligation shall be limited to repairing or replacing, at its option, free of charge for materials or labor, any part which is proved not in compliance with Seller's specifications or proves defective in materials or workmanship under normal use and service. This warranty is void if the product is altered or improperly repaired or serviced by anyone other than IntelliSense factory service. For warranty service, contact the nearest IntelliSense service center. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE INTELLISENSE FG-1015




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual INTELLISENSE FG-1015 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.