User manual INFOSEC XP PRO 1000 VA

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual INFOSEC XP PRO 1000 VA. We hope that this INFOSEC XP PRO 1000 VA user guide will be useful to you.


INFOSEC XP PRO 1000 VA : Download the complete user guide (1204 Ko)

Manual abstract: user guide INFOSEC XP PRO 1000 VA

Detailed instructions for use are in the User's Guide.

[. . . ] In the event of power failure due to power cuts, power surges, or transient over-voltage, the UPS will very rapidly transfer your computer equipment to an alternative power supply source. This will allow you to make a backup, exit your program and shut the system down correctly. In normal power supply conditions for your equipment, the XP Pro will maintain its battery charge in an on-going way to become completely transparent during all your operations. In other words, this kind of uninterruptible multifunctional power supply will simplify your tasks. [. . . ] Batteries kept in storage should be recharged every 3 months, failure to do so could result in battery damage. When calling the After-Sales Department, please have the following information ready, it will be required regardless of the problem: UPS model, serial number and date of purchase. give an accurate description of the problem including the following details: type of equipment powered by the UPS , indicator led status , alarm status , installation and environmental conditions. You will find the technical information you require on your guarantee or on the identification plate on the back of the unit. At the end of their useful lives, they have to be collected separately and should not be discarded with household refuse. Checking When you receive your equipment, open the packaging and check that your UPS has not been damaged. The packaging includes: a UPS unit, 1 input power cord, 3 IEC output cables, 1 communication interface cable (USB connector), 1 RJ11 cable, 1UPSurf Control Software and a user guide. Charging the batteries This unit is shipped from the factory with its internal battery fully charged, however, some charge may be lost during shipping and the battery should be recharged prior to use. Plug the unit into an appropriate power supply and allow the UPS to charge fully by leaving it plugged-in, with no load, for at least 8 hours. The UPS will automatically recharge its own batteries whenever the switch is in the "ON" position ("ON LINE" green led on). You may use the UPS immediately however the back-up power capacity may be lower than the nominal value required. Where to set up The UPS has been designed to operate in a protected environment, at temperatures between 0° C and 40° C and at a humidity level ranging between 0 % and 90% (no condensation). Install the unit in an environment which is free from dust, chemical vapours and conductors. Moreover, in order to avoid any interference, keep the UPS at least 20 cm away from the CPU (central processing unit). Connection Check on the identification plate at the back of the UPS that the power supply is compatible with network voltage and that the device is powerful enough to protect the given power load. Plug the UPS into a 2-pole, earthed outlet (use the original power cable of your computer or a 2P+E/CEE22/10A power cable is recommended). Then, use the 3 IEC cables to connect one computer-related device to each of the power outlets supplied on the back of the UPS. For XP Pro 1000 and 1250, you may also connect a device that does not require backup, such as an inkjet printer, to one of the surge protected outlets. To start the UPS in the absence of a power supply and with a fully-charged battery, press the button. If no load connects to the UPS, it will automatically shut down after 5 minutes to save energy during a power failure. [. . . ] Batteries have a very high short circuit current: connection errors could cause electric arcs resulting in serious burns. TROUBLE SHOOTING Should the UPS fail to function correctly we recommend you to perform the following tests before calling the Hot Line. Power switch was not pressed for at least 5 seconds Press and hold power switch for at least 5 seconds. Line Interactive with Automatic Voltage Regulation (AVR) Modified sine wave Discharge / Overcharge and overload protection + fax modem line protection 1000 VA 1250 VA 1600 VA 2000 VA 0. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE INFOSEC XP PRO 1000 VA




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual INFOSEC XP PRO 1000 VA will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.