User manual IDEAL TEST PRO 360

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual IDEAL TEST PRO 360. We hope that this IDEAL TEST PRO 360 user guide will be useful to you.


IDEAL TEST PRO 360 : Download the complete user guide (265 Ko)

Manual abstract: user guide IDEAL TEST PRO 360

Detailed instructions for use are in the User's Guide.

[. . . ] Before beginning all unknown measurements, set meter to the highest range possible. Page 2 WARNING!Before breaking a circuit for testing, turn off the power to the circuit. When disconnecting from a circuit, disconnect the hot lead first, then the common lead. Disconnect the meter from the circuit before turning off any indicator, including motors, transformers, and solenoids. [. . . ] LLL 600V MFD R/L1 MAX 2A FUSED COM ! 600V MAX 350V/15 SEC FOR 200mV RANGE V Reverse Bias + - Red Black Function Diode Test Range 2 VDC Resolution 1 mV Accuracy ± (3. 0% + 1) Diode Testing: To ensure a proper functioning diode, the meter will develop a voltage across the component from a test current. The diode test function allows measurements of forward and reverse bias across diodes and transistor junctions. Turn off power to the device or circuit that is being tested and discharge all capacitors. Plug the leads into the meter inputs as indicated in the above diagram. Select the diode function on the meter. Page 9 Page 10 Continuity Beeper (beeps at resistance <150) Current (AAC and ADC) PHASE ROTATION-TRUE RMS HZ-MFD-AUTO OFF VAC PHASE ROTATION-TRUE RMS HZ-MFD-AUTO OFF 2000m 200m RST Hz 200M 2000m RST Hz 200M 20M 200 200m 20M 600 200 600 200 VDC 200m 20 2000m 200m VAC 2000m 200m 600 200 600 200 VDC 20 ADC AAC 200 2k 20k ADC AAC 200 200k 20k 2k 200 20k 2k ADC AAC 200k 20k 2k 200 20k MFD MFD 2A MFD CAT. LLL 600V M 200k 20k 2k 200 20k 2k MFD R/L1 MAX 2A FUSED COM ! 600V MAX 350V/15 SEC FOR 200mV RANGE V 2A MFD CAT. R/L1 MAX 2A FUSED V A D 600V MAX 350V/15 SEC FOR 200mV RANGE Red Red Black Black Function AC Current DC Current Range 2. 000 A 2. 000 A Resolution . 001 A . 001 A Accuracy ± (3. 0% + 4) 50 to 500Hz To Verify Continuity: A continuity test ensures that all circuit connections are intact. Plug the test leads into the meter inputs as indicated in the diagram above. If the beeper sounds, the circuit is complete. To Measure Current: Current is measured in amps. Do not attempt to measure current in circuits capable of delivering greater than 600V. Connect the test leads into the meter inputs as indicated in the diagram above. Measure the Current. Page 11 Page 12 Frequency (Hz) Phase Rotation (RST) PHASE ROTATION-TRUE RMS HZ-MFD-AUTO OFF VAC 2000m 200m RST Hz 200M 20M k PHASE ROTATION-TRUE RMS HZ-MFD-AUTO OFF 200 VAC 2000m 200m RST 600 200 600 200 VDC 20 2000m 200m VAC 2000m 200m RST Hz 200M 20M 200k 2A MFD 2000m 200m RST Hz 200M 20M 600 200 600 200 VDC 20 2000m 200m Hz 200M 20M ADC AAC 200 200k 20k 2k 200 20k 2k ADC AAC 200 200k 20k 2k 200 20k 2k MFD MFD 2A MFD CAT. R/L1 MAX 2A FUSED V R/L1 MAX 2A FUSED 600V MAX 350V/15 SEC FOR 200mV RANGE R 600V MAX 350V/15 SEC FOR 200mV RANGE T Red Black Function Phase Rotation Indicator S Frequency Range 50 Hz to 500 Hz Voltage Range 80V to 500V LCD indicates sequence of three-phases. Function Range Resolution Accuracy Frequency 10 Hz to 100 kHz for AC ±(2% + 3 digits) 10 Hz to 100 Hz for DC* . 001 kHz Sensitivity : 3. 5 V rms *DC Voltage higher than 3. 5 V rms To Determine Phase Rotation (RST): This test function correctly identifies each of the 3-Phases in a power panel as R, S, T. Note: The displayed numerical value has no meaning when performing this procedure. Plug the test leads into the meter inputs labeled as R, S, T in the diagram above. Attach the three test leads to each of the 3-Phase cables in any order. If all three supply lines have power, the meter will indicate a R, S, T (in the upper left corner). Frequency is measured in Hertz: Do not attempt to measure frequency in circuits capable of delivering greater than 600V. Plug test leads into the meter inputs as indicated in the diagram above. Measure the frequency. Page 13 Page 14 Phase Rotation (continued) 7. If the meter indicates "OK" in the display (upper left-hand side), a. Label each phase cable as R, S, or T following the test lead connections to the labeled meter inputs. If the meter indicates an message in the display (lower left-hand side), the phase rotation is counter-clockwise. [. . . ] Inspect the test leads for breaks or cracks, and ensure that the test leads are inserted fully into the input connectors. If problem persists, meter should be inspected by a qualified service person. Page 19 LIFETIME LIMITED WARRANTY This meter is warranted to the original purchaser against defects in material or workmanship. will, at its option, replace or repair the defective unit, subject to verification of the defect or malfunction. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE IDEAL TEST PRO 360




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual IDEAL TEST PRO 360 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.