User manual IDEAL ND2396

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual IDEAL ND2396. We hope that this IDEAL ND2396 user guide will be useful to you.


IDEAL ND2396 : Download the complete user guide (174 Ko)

Manual abstract: user guide IDEAL ND2396

Detailed instructions for use are in the User's Guide.

[. . . ] #61-802 1 800 Series Power Clamp Meter 61-802 Power Clamp 3ØPF AC+DC 2000KW 2000A HOLD 3 4 2 PFKW HzV VA OFF KVARKVA 3Ø3W 3Ø4W True RMS 5 61-802 DC A/W ZERO REC 3Ø KVAR KVA READ NEXT 6 CAT III - 600V Power Clamp 3ØPF AC+DC 2000KW 2000A HOLD PFKW HzV VA OFF 7 KVARKVA 3Ø3W 3Ø4W True RMS DC A/W ZERO REC 3Ø KVAR KVA READ NEXT 1. DO NOT UNDER ANY CIRCUMSTANCES EXCEED THESE RATINGS: - Voltage is not to exceed 800 Volts. - Wattage, Resistance and Continuity functions are not to be performed on circuits capable of delivering greater than 600 Volts. - Current measurements are not to be performed on circuits capable of delivering greater than 500 Volts 2. [. . . ] AC + DC Apparent Power/Reactive Power Measurement (kVA/kVAR) 61-802 Power Clamp 3ØPF AC+DC 2000KW 2000A HOLD PFKW HzV VA OFF Overload Protection: 800V TRMS Measurements Accuracies specified at Crest Factor <3. 5 KVARKVA 3Ø3W 3Ø4W True RMS DC A/W ZERO REC 3Ø KVAR KVA READ NEXT CAT III - 600V 61-802 Power Clamp 3ØPF AC+DC 2000KW 2000A HOLD PFKW HzV VA OFF KVARKVA 3Ø3W 3Ø4W True RMS Note: Before taking a kVA/kVAR measurement, the DC A/W ZERO button must be used to zero the current reading. If the current reading is not zero, the kVA and kVAR values might be incorrect. DC A/W ZERO REC 3Ø KVAR KVA READ NEXT CAT III - 600V 9 10 To Measure AC+DC Apparent and Reactive Power (kVA/kVAR) in a single phase 2-wire system · Set the rotary switch to A/V. · Insert the black test lead into the COM terminal and the red test lead into the + terminal. · Connect the black test probe to the neutral conductor and the red test probe to the hot conductor. · Using the trigger to open the jaws, fully enclose the hot conductor within the clamp. · Release the trigger and be sure that the jaws have closed completely. · Apparent Power (kVA) is a calculated value based on the formula VA kVA = 1000 · Reactive Power (kVAR) is a calculated value based on the formula kVAR = (kVA)2 - (kW)2 33W AC+DC Power Measurements Kilowatt Range Resolution Accuracy (AC+DC True Power) Range 0-99. 99kW 100-999. 9kW 1000-1200kW 0. 01kW 0. 1kW 1kW ±(2. 0% +5) Voltage/Current ±(2. 0% +0. 05) 600VAC, 800VDC 2000A AC/DC Power Factor 0. 2-1. 0 for 12W, 13W, 33W, and 34W KVAR Range Resolution Accuracy (AC+DC Reactive Power) 0-99. 99kW 100-999. 9kW 1000-1200kW 0. 01kW 0. 1kW 1kW ±(2. 0% +5) Voltage/Current Range 2000A AC/DC ±(2. 0% +0. 05) 600VAC, 800VDC In a three phase 3-wire system, the 61-802 power clamp measures the true power (kW), power factor (PF), apparent power (kVA), and reactive power (kVAR) of the system. These values are calculated based on the formulas kW33W = PF33W = kVA33W = kWRS(L1L2) + kWTS (L3L2) kW 33W kVA 33W kW233W - kVAR233W · To obtain a more accurate kVAR value when the power factor (PF) is greater than 0. 91, use the 33W function. · The kVA value is shown on the main display and the kVAR value is shown on the upper display. · Positive kVAR (+) indicates a capacitive load, while negative kVAR (-) indicates an inductive load. Note: The "+" sign on the jaw must face the power source for correct measurement. To measure AC+DC Apparent and Reactive Power (kVA/kVAR) in a single phase 3-wire system See section on 13W AC+DC Power Measurements kVAR33W = kVARS(L1L2) + kVARTS(L1L2) To Measure AC+DC Power Measurements in a three phase 3-wire system · Set rotary switch to 33W without jaws clamping onto any wire. · The LCD display will show a flashing R to indicate that the meter is ready for the first measurement. · If the watt reading is not zero, press the DC A/W ZERO button once to zero out the watt reading. · Insert the black test lead into the COM terminal and the red test lead into the + terminal. · Pressing the READ NEXT button clears the stored data from memory and readies the power clamp for another three phase 3-wire calculation. Note: The "+" sign on the jaw must face the power source for correct measurement. Note: In the 33W unbalanced power measurement, one of WRS or WTS could be negative. Make sure all the connections and clamping are correct to obtain correct power and power factor measurements. 13W AC+DC Power Measurements The measurements for a single phase 3-wire system are similar to a three phase 3-wire unbalanced measurements, except the nomenclature is different. To Measure AC+DC Power Measurements in a single phase 3-wire system · Set rotary switch to 33W without jaws clamping onto any wire. · The LCD display will show a flashing R to indicate that the meter is ready for the first measurement. [. . . ] · Release the trigger and be sure that the jaws have closed completely. · Wait until the reading is stable, and press the READ NEXT button to capture the reading, storing the data in memory. DC A/W ZERO REC 3Ø KVAR KVA READ NEXT CAT III - 600V 19 20 Power Calculations Power Factor Corrections A positive power factor indicates that an inductive load has brought the power system out of phase. Based on the kVAR values of the system, capacitors are available to improve the power factor. By measuring the frequency, phase voltage and kVAR of the system, you can calculate the capacitive load required for this correction. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE IDEAL ND2396




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual IDEAL ND2396 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.