User manual IDEAL ND2385

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual IDEAL ND2385. We hope that this IDEAL ND2385 user guide will be useful to you.


IDEAL ND2385 : Download the complete user guide (311 Ko)

Manual abstract: user guide IDEAL ND2385

Detailed instructions for use are in the User's Guide.

[. . . ] Before beginning all unknown measurements, set meter to highest possible range. Before breaking a circuit for testing, turn off the power to the circuit. When disconnecting from a circuit, disconnect the hot lead first, then the common lead. Disconnect the meter from the circuit before turning off any indicator, including motors, transformers, and solenoids. [. . . ] Plug the Black test lead into the COM port and the Red test lead into the port. Measure DC Voltage Input Impedance: 10M (over 1000M in 400mV range) 7 8 AC Current Circuit Connection: DC Current Circuit Connection: ~Hz MIN/MAX PEAK HOLD ~Hz MIN/MAX PEAK HOLD Data Acquisition Data Acquisition 2 2 Range Resolution Max Display Accuracy 40mA 400mA 10A 1µA 0. 1mA 10mA 40. 00 400. 0 10. 00 Voltage Burden +(1. 0% +5) 300mV max 3V max +(2. 0% +5) 3V max Range Resolution Max Display Accuracy 40mA 400mA 10A 10µA 0. 1mA 10mA 40. 00 400. 0 10. 00 Voltage Burden +(0. 4% +2) 300mV max +(0. 5% +2) 3V max +(1. 0% +3) 3V max To Measure AC Current: 1. Plug the Black test lead into the COM port and the Red test lead into the mA or A port. Frequency Response: 40Hz ~ 1kHz Overload Protection: 1A, 600V IR 10kA fuse for mA input 15A, 600V IR 100kA fuse for A input To Measure DC Current: 1. Plug the Black test lead into the COM port and the Red test lead into the mA or A port. Overload Protection: 1A, 600V IR 10kA fuse for mA input 15A, 600V IR 100kA fuse for A input 9 10 Frequency/RPM Circuit Connection: Resistance (Ohms) Circuit Connection: ~Hz MIN/MAX PEAK HOLD ~Hz MIN/MAX PEAK HOLD Data Acquisition Data Acquisition 2 2 Range 4kHz/40kRPM Resolution 1Hz/30RPM Max Display Sensitivity Accuracy 4. 000/40. 00 150mV 2. 0 Hz 1. 5V < 20 Hz Frequency: 0. 01% +1 RPM: 0. 01% + 10 40kHz/400kRPM 400kHz/4MRPM 4MHz/40MRPM 40MHz/400MRPM 10Hz/300RPM 100Hz/3KRPM 1kHz/30KRPM 40. 00/400. 0 400. 0/4. 000 4. 000/40. 00 300mV 1V *** Range 400 4k 40k 400k 4M 40M Resolution 0. 1 1 10 100 1K 10K Max Display 400. 0 4. 000 40. 00 400. 0 4. 000 40. 00 Accuracy ±(0. 7% +3) ±(0. 4% +2) ±(0. 6% +3) ±(1. 5% +5) 10kHz/300KRPM 40. 00/400. 0 400MHz/4000MRPM 100kHz/3MRPM 400. 0/4000 *This spec is not guaranteed. Plug the Black test lead into the COM port and the Red test lead into the VHz port. Turn the power off to the circuit or device that is to be measured and discharge all capacitors before attempting a measurement. Plug the Black test lead into the COM port and the Red test lead into the VHz port. For correct reading, ensure that the device being tested contains no voltage. Overload Protection: 600V Open Circuit Voltage: -1. 3V (approx. ) 12 Capacitance Circuit Connection: Diode Testing Circuit Connection: ~Hz MIN/MAX PEAK HOLD ~Hz MIN/MAX PEAK HOLD Data Acquisition Data Acquisition 2 2 Range 4nF 40nF 400nF 4µF 40µF 400µF 4mF 40mF Resolution 1pF 10pF 100pF 1nF 10nF 100nF 1µF 10µF Max Display Accuracy 4. 000 +(3. 0% +10) 40. 00 +(3. 0% +5) 400. 0 4. 000 40. 00 400. 0 4. 000 +(5. 0% +20)* 40. 00 Function Resolution Accuracy Max. Open Current Circuit Voltage 1. 5mA 3V 1mV +(1. 5% +5) * For 0. 4V to 0. 8V. Turn off power to the device or circuit that is being tested and discharge all capacitors. Plug the Black test lead into the COM port and the Red test lead into the VHz port. Normally the forward voltage drop of a good silicone diode is shown between 400V and 0. 9V. If the diode under test is defective, "000" (short circuit) or "OL" (non-conductive) is displayed. Overload Protection: 600V max * In these two ranges the reading may be rolling within specification To Measure Capacitance: 1. Turn the power off to the circuit or device that is to be measured and discharge all capacitors before attempting a measurement. Plug the Black test lead into the COM port and the Red test lead into the VHz port. Measure Capacitance In order to ensure the best accuracy in measurement of low capacitance, open the test leads before measurement and memorize the test probe capacitance. It is necessary to subtract the capacitance of the test probes themselves, or use the relative mode to compensate for the test leads. Overload Protection: 600V 13 14 Continuity Check Circuit Connection: PEAK Hold Measurements ~Hz MIN/MAX PEAK ~Hz HOLD MIN/MAX PEAK HOLD Data Acquisition Data Acquisition 2 2 To Verify Continuity: 1. [. . . ] This warranty does not apply to defects resulting from abuse, neglect, accident, unauthorized repair, alteration, or unreasonable use of the instrument. Fuse Replacement 1. Remove the test leads from the front terminals and turn the meter off. Remove the two screws connecting the top and bottom cases of the meter. Remove the defective fuse by gently prying one end of the fuse loose and sliding the fuse out of the fuse holder. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE IDEAL ND2385




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual IDEAL ND2385 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.