User manual IDEAL 61320

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual IDEAL 61320. We hope that this IDEAL 61320 user guide will be useful to you.


IDEAL 61320 : Download the complete user guide (89 Ko)

Manual abstract: user guide IDEAL 61320

Detailed instructions for use are in the User's Guide.

[. . . ] Before breaking a circuit for testing, turn off the power to the circuit. When disconnecting from a circuit, disconnect the hot lead first, then the common lead. Disconnect the meter from the circuit before turning off any indicator, including motors, transformers, and solenoids. 2 4 1 3 1. Min/Max Switch · Pressing this button once results in the displayed maximum value of the current reading. [. . . ] Plug the black test lead into the COM port and the red test lead into the Hz V µA port. Measure AC Voltage. 6 DC Volts Circuit Connection: Range 600mV 6V 60V 600V 1000V Resolution 100µV 1mV 10mV 100mV 1V Max. Display 600. 0 ±(0. 5% reading 6. 000 + 2 digits) 60. 00 600. 0 1000 Accuracy Input Impedance: 10M (over 1000M in 600mV range) To Measure DC Voltage: 1. Plug the black test lead into the COM port and the red test lead into the Hz V µA port. Measure DC Voltage 7 DC Current Circuit Connection: Range Resolution 600µA 6000µA 0. 1µA 1µA Voltage Max Burden ±(1. 0% reading < 4mV / µA 600. 0 + 2 digits) 6. 000 Accuracy Overload Protection: µA input: 600V RMS To Measure DC Current: 1. Plug the black test lead into the COM port and the red test lead into the Hz V µA port. Measure DC Current. 8 Frequency/RPM Circuit Connection: Range 6000Hz 60KHz 600KHz 6MHz 60MHz Resolution 1Hz 10Hz 100Hz 1KHz 10KHz Sensitivity 100mV RMS Accuracy Frequency: 0. 01% ±1 digit 250mV RMS 1V RMS Overload Protection: 600V rms *Less than 20Hz the sensitivity is 1. 5V To Measure Frequency: 1. Plug the black test lead into the COM port and the red test lead into the Hz V µA port. Measure Frequency. 9 Resistance (Ohms) Circuit Connection: Range 600 6K 60K 600K 6M 60M Resolution Accuracy Max. Display 0. 1 600. 0 1 ±(0. 7% reading 6. 000 10 + 2 digits) 60. 00 100 600. 0 1K 6. 000 10K 60. 00 Open Circuit Voltage: -1. 3V approx. Turn the power off to the circuit or device that is to be measured and discharge all capacitors before attempting a measurement. Plug the black test lead into the COM port and the red test lead into the Hz V µA port. For correct reading, ensure that the device being tested contains no voltage. 10 Multiplication Guide for Ohms (): 400 = Meter indicates actual resistance 4k = Multiply meter display reading by 1, 000 to acquire actual resistance. 40k = Multiply meter display reading by 1, 000 to acquire actual resistance. 400k = Multiply meter display reading by 1, 000 to acquire actual resistance. 4M = Multiply meter display reading by 1, 000, 000 to acquire actual resistance 400M = Multiply meter display reading by 1, 000, 000 to acquire actual resistance. The meter displays total resistance through all possible paths between the probe-tips. These multiple paths may result in measurements that do not correspond to the ohm value indicated by the resistor color code. 11 Determining Resistor Values: To determine the value of a resistor, use the color bands on the resistor and the table on the following page. Resistor Color Code Table 1st Color Digit Black 0 Brown 1 Red 2 Orange 3 Yellow 4 Green 5 Blue 6 Violet 7 Gray 8 White 9 Gold Silver No Color Example: 2nd Tolerance Digit Multiplier (Percentage) 0 1 1 10 2 100 3 1, 000 4 10, 000 5 100, 000 6 1, 000, 000 7 10, 000, 000 8 100, 000, 000 9 1, 000, 000, 000 +/- 5% +/- 10% +/- 20% 1st color band is blue so the first digit is a 6 2nd color band is red so the second digit is a 2 3rd color band is yellow so multiply 62 x 10, 000 4th color band is gold so the tolerance is ±5% Your Resistor value is 620, 000 Ohms (620k) with a tolerance of ±5%. 12 Blue Red Yellow Gold Diode Testing Function Resolution Accuracy Max. Test Max. Open Current Circuit Voltage 1mV * For 0. 4V to 0. 8V. Overload Protection: 600V rms max Diode Check: To ensure a proper functioning diode, the meter will develop a voltage across the component from a test current. The diode test function allows for measurements of forward voltage drops across diode and transistor junctions. [. . . ] Battery Installation or Replacement: The #61-320 is powered by two 1. 5V batteries. Remove the test leads from the front terminals and turn the meter off. Make sure the battery box leads do not become pinched between the case and battery cover before replacing the battery cover and screw. 18 Fuse Replacement 1. Remove the test leads from the front terminals and turn the meter off. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE IDEAL 61320




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual IDEAL 61320 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.