User manual IDEAL 320 CONTRACTOR GRADE MULTIMETER

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual IDEAL 320 CONTRACTOR GRADE MULTIMETER. We hope that this IDEAL 320 CONTRACTOR GRADE MULTIMETER user guide will be useful to you.


IDEAL 320 CONTRACTOR GRADE MULTIMETER : Download the complete user guide (77 Ko)

Manual abstract: user guide IDEAL 320 CONTRACTOR GRADE MULTIMETER

Detailed instructions for use are in the User's Guide.

[. . . ] Before beginning all unknown measurements, set meter to highest possible range. Before breaking a circuit for testing, turn off the power to the circuit. When disconnecting from a circuit, disconnect the hot lead first, then the common lead. Disconnect the meter from the circuit before turning off any indicator, including motors, transformers, and solenoids. 2 2 1 5 3 4 1. [. . . ] To disable the auto power off function, power up the meter while pressing either the range, RS-232 or min/max. button. 4 Overload Protection Function VAC & VDC AAC & ADC Ohms () Diode Continuity Overload Protection 1000V A input: 1A(600V) fast blow fuse µA input: 600V RMS 600VAC/600VDC 600VAC/600VDC 600VAC/600VDC Unit of Measure Multipliers For your reference, the following symbols are often used to make measurement easier: Symbol Verbal Multiplier M mega x 1, 000, 000 k kilo x 1, 000 m milli ÷ 1, 000 µ micro ÷ 1, 000, 000 5 True RMS AC Volt Circuit Connection: Range 600mV 6V 60V 600V 1000V Resolution 100µV 1mV 10mV 100mV 1V Max. Display 600. 0 ±(0. 9% reading 6. 000 + 5 digits) 60. 00 600. 0 1000 Accuracy AC Conversion Type: AC conversions are AC-coupled, true RMS responding, calibrated to the RMS value sine wave input. Plug the black test lead into the COM port and the red test lead into the Hz V µA port. Measure AC Voltage. 6 DC Volts Circuit Connection: Range 600mV 6V 60V 600V 1000V Resolution 100µV 1mV 10mV 100mV 1V Max. Display 600. 0 ±(0. 5% reading 6. 000 + 2 digits) 60. 00 600. 0 1000 Accuracy Input Impedance: 10M (over 1000M in 600mV range) To Measure DC Voltage: 1. Plug the black test lead into the COM port and the red test lead into the Hz V µA port. Measure DC Voltage 7 True RMS AC Current Circuit Connection: Range Resolution 60mA 600mA 10µA 100µA Accuracy +(1. 5% reading +5 Voltage Burden 2V max Max 60. 00 600. 0 AC Conversion Type: AC conversions are AC-coupled, true RMS responding, calibrated to the RMS value sine wave input. Overload Protection: A input: 1A (600V) fast blow fuse Crest Factor: +1. 5% additional error for C. F. from 3 to 4 Frequency Response: 40 Hz ~ 500Hz To Measure True RMS AC Current: 1. Plug the black test lead into the COM port and the red test lead into the mA. 8 DC Current Circuit Connection: Range Resolution 600µA 6000µA 60mA 600mA 0. 1µA 1µA 10µA 100µA Voltage Max Burden < 4mV / µA 600. 0 ±(1. 0% reading 6. 000 + 2 digits) 2V max 60. 00 600. 0 Accuracy Overload Protection: A Input: (600V) fast blow fuse µA Input: 600V RMS To Measure DC Current: 1. Plug the black test lead into the COM port and the red test lead into the mA or Hz V µA port. Measure DC Current. 9 Frequency/RPM Circuit Connection: Range 6000Hz 60KHz 600KHz 6MHz 60MHz Resolution 1Hz 10Hz 100Hz 1KHz 10KHz Sensitivity 100mV RMS Accuracy Frequency: 0. 01% ±1 digit 250mV RMS 1V RMS Overload Protection: 600V rms *Less than 20Hz the sensitivity is 1. 5V To Measure Frequency: 1. Plug the black test lead into the COM port and the red test lead into the Hz V µA port. Measure Frequency or RPM. 10 Resistance (Ohms) Circuit Connection: Range 600 6K 60K 600K 6M 60M Resolution Accuracy Max. Display 0. 1 600. 0 1 ±(0. 7% reading 6. 000 10 + 2 digits) 60. 00 100 600. 0 1 6. 000 10 60. 00 Open Circuit Voltage: -1. 3V approx. Turn the power off to the circuit or device that is to be measured and discharge all capacitors before attempting a measurement. Plug the black test lead into the COM port and the red test lead into the Hz V µA port. For correct reading, ensure that the device being tested contains no voltage. 11 Multiplication Guide for Ohms () 400 = Meter indicates actual resistance 4k = Multiply meter display reading by 1, 000 to acquire actual resistance. 40k = Multiply meter display reading by 1, 000 to acquire actual resistance. [. . . ] Plug the black test lead of the clamp adapter handle into the COM port and the red test lead into the Hz V µA port. Snap the jaw of the current clamp around one of the current carrying conductors. Additional Current Clamps: 200AAC 61-332 500 AAC 61-333 600 AAC/DC 61-334 1000 AAC 61-436 Flexible Clamp Adapters: 1000 AAC 61-330 3000 AAC 61-31 17 General Specifications LCD Display: Polarity Indication: 6000 count maximum reading Automatic, negative indicated, positive implied Overrange Indication: "OL" or "-OL" Low Battery Indication: " " when the battery voltage drops below operating voltage Size (WxHxD): 82mm x 164mm x 44mm (without holster) Sampling: 1 time/sec LCD Display, Auto Power Off: Approx. Operating Temperature: 0°C ~ 30°C (<80% RH), 30°C ~ 40°C (<75% RH), 40°C ~ 50°C (<45% RH) Storage Temperature: -20°C ~ 60°C (0~80% RH) when battery removed from meter Temperature Coefficient: 0. 15 x (specified accuracy) / °C, <18°C or >28°C Power Requirements: 9V NEDA 1604, 1EC bf 22, J1S 006P Battery Life: 300 hours (alkaline ) Installation Category: IEC 1010, 1000V Cat. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE IDEAL 320 CONTRACTOR GRADE MULTIMETER




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual IDEAL 320 CONTRACTOR GRADE MULTIMETER will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.