User manual ICOM IC-U200

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual ICOM IC-U200. We hope that this ICOM IC-U200 user guide will be useful to you.


ICOM IC-U200 : Download the complete user guide (1746 Ko)

Manual abstract: user guide ICOM IC-U200

Detailed instructions for use are in the User's Guide.

[. . . ] It records up to a maximum of 8 minutes (Or up to 48 calls of 10 sec. recording time). " " icon on the display shows you have a new message. 700mW audio output The IC-U200 delivers a loud 700mW* audio output with the built-in BTL amp. The built-in audio compander provides clear, low noise communications. [. . . ] * Typical with internal speaker. Lone worker function for remote check in When the radio is not operated for a preset period (1 to 255 min. ), the radio sounds a beep and requires you to push the emergency button. If the emergency button is not pushed for a preset time (1 to 255 sec. ), an emergency signal automatically transmits and informs your co-worker or dispatcher that something may have happened to the individual worker. IP67, dust-tight and waterproof protection The IC-U200 has outstanding protection against dust and water that is equivalent to IP67. The ICF51V can withstand submersion in 1m depth of water for up to 30 minutes and has dust-tight construction that prevents the ingress of dust. Most popular signalings built-in Use the built-in CTCSS, DTCS, 2-Tone, 5-Tone and BIIS signaling capabilities to set up your talk group or selective calling. The IC-U200 can decode ten 2-Tone codes or eight 5-Tone codes on a channel. When a matched tone is received, the following actions are programmable for each code. · Bell icon · Answer back call · Beep sound · Auto transmit · Radio Stun/Kill/Revive · Voice recorder · Vibration alert VHF TRANSCEIVER alert and voice recorder! BP-226 BP-227 BC-147 BC-152 portant calls BIIS 1200 Compatible · 32 abbreviated call memories · RS-232C interface · 7 group IDs · 24-status Messages · Radio stun · 8-character SDM (Short Data Message) · Position data transmission with optional HM-170GP OPTIONS BATTERY PACK & CASE Some options may not be available in some countries. Please ask your dealer for details. BATTERY CHARGER The following selective calling and ANI features are available with the built-in BIIS signaling. The following selective calling and data communication features are available with the BIIS system. BP-226 : AA (LR6)×5 BATTERY CASE BP-226 is water-resistant, equivalent to IPX4. BP-227 : 7. 2V/1700mAh Li-Ion BATTERY PACK Provides 9­10 hours operating time* (approx. ). Operating temp. 128 channels/ 8 zones : 12. 5/20/25kHz : 2. 5/3. 125kHz : 50 (SMA Type) · Sensitivity · Squelch sensitivity : ­4dBµV typ. (emf, at threshold) · Adjacent channel selectivity : 75dB typ. (narrow) · Spurious response · Intermodulation · Hum and noise (With CCITT filter) : 70dB : 67dB typ. (External speaker) at 5% distortion with an 8 load · Power supply requirement : 7. 2V DC · Current drain (approx. ) : Transmit at 5W 1. 8A at 1W 0. 7A Receive AF max. 500mA (Internal speaker) 350mA (External speaker) Stand-by 85mA · Operating temperature range : ­25°C to +55°C · Dimensions (W×H×D) (projections not included) · Audio output power · External SP connector : 9-pin multi connector/8 : 56 × 97 × 36. 4mm Applicable U. S. Military Specifications · Weight (approx. ) : 280g (With BP-227) Icom makes rugged products that have been tested to and passed the following MIL-STD requirements and strict environmental standards. Standard Low Pressure High Temperature Low Temperature Temperature Shock Solar Radiation Rain Humidity Salt Fog Dust Blowing Vibration Shock Also meets equivalent MIL-STD-810-C, -D and -E. MIL 810F Method 500. 4 501. 4 502. 4-3 503. 4 505. 4 506. 4 507. 4 509. 4 510. 4 514. 5 516. 5 Procedure I, II I, II I, II I I I, III ­ ­ I I I, IV TRANSMITTER · Output power · Modulation system : 5. 0W : Variable reactance frequency modulation · Max. frequency deviation : ±5kHz (wide) ±4kHz (middle) ±2. 5kHz (narrow) · Frequency error · Spurious emissions · Modulation limiting : ±2. 5ppm : 0. 25µW ( 1GHz) 1. 0µW (> 1GHz) : 60­100% of Max. deviation Ingress Protection Standard Dust & Water IP67 (Dust-tight and waterproof protection) Supplied accessories: · Antenna (Length may differ according to version) · Audio harmonic distortion : 3% typ. [. . . ] frequency deviation : ±5kHz (wide) ±4kHz (middle) ±2. 5kHz (narrow) · Frequency error · Spurious emissions · Modulation limiting : ±2. 5ppm : 0. 25µW ( 1GHz) 1. 0µW (> 1GHz) : 60­100% of Max. deviation Ingress Protection Standard Dust & Water IP67 (Dust-tight and waterproof protection) Supplied accessories: · Antenna (Length may differ according to version) · Audio harmonic distortion : 3% typ. (narrow) · External MIC impedance : 9-pin multi connector/2. 2k Measurements made in accordance with ETS 300-086. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ICOM IC-U200




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual ICOM IC-U200 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.