Detailed instructions for use are in the User's Guide.
[. . . ] AVOID using or placing the receiver in direct sunlight or in
areas with temperatures below 10°C (+14°F) or above +60°C (+140°F). Even when the receiver power is OFF, a slight current still flows in the circuits. Remove batteries from the receiver when not using it for a long time, otherwise, the installed batteries will become exhausted. REMOVE any cables from the [DC 6V] jack after operation or charging a battery pack. [. . . ] w Rotate [DIAL] to select a memory channel to be programmed as a skip channel. e While pushing [FUNC], push [(V/M) SKIP] one or more times to select a condition.
: channel will not be skipped. · "PSKIP" or "P " appears : channel skipped during memory scan; frequency skipped during full, band and programmed scans. · No indication · "SKIP" or " " appears
FM
M:A00 146. 010. 000 15. 0
FM
M:A00 146. 010. 000 15. 0
SKIP
FM
M:A00 146. 010. 000 15. 0
PSKIP
TS
TS
TS
S1
VOL
3
5
7
9
S1
VOL
3
5
7
9
S1
VOL
3
5
7
9
FM
FM
FM
P
Non-skip channel
Skip channel
Skip channel and frequency skip channel
I Scan resume condition
Setting the scan pause time
The scan pauses when receiving signals according to the scan pause time. q Push [FUNC] + [(MODE) SET] momentarily to enter set mode.
· Select a non-band scope screen in advance for color LCD.
This setting is effective when the frequency skip function ("PSKIP" or "P ") is turned ON. 24 for details.
w Rotate [DIAL] until "Pause Scan" or "PAUSE" appears.
· "PAUSE" disappears after 1 sec. and the previously selected scan pause time and "PA" appears when color LCD is OFF.
22
SCAN OPERATION
e Push [] or rotate the tuning dial while pushing [FUNC] to select the desired scan pause time.
· "2SEC""20SEC" : scan pauses for 220 sec. · "HOLD" : scan pauses on a received signal until it disappears.
6
w Rotate [DIAL] until "Scan Resume" or "RESUmE" appears.
· "RESUmE" disappears after 1 sec. and the previously selected scan resume time and "RE" appears when color LCD is OFF.
e Push [] or rotate the tuning dial while pushing [FUNC] to select the desired scan resume time.
· "1SEC""5SEC" : scan restarts 15 sec. · "0SEC" : scan restarts immediately after the signal disappears. · "HOLD" : scan restarts by rotating [DIAL] only.
r Push [(MODE) SET] to exit set mode.
Pause Scan Priority Beep Audio Light A. Power OFF : 10SEC : OFF : VOLUME : AUTO : OFF Pause Scan Priority Beep Audio Light A. Power OFF : 10SEC : OFF : VOLUME : AUTO : OFF Pause Scan Priority Beep Audio Light A. Power OFF : HOLD : OFF : VOLUME : AUTO : OFF
r Push [(MODE) SET] to exit set mode.
Tone Squelch: OFF Tone Freq. 22) · If the priority watch with alert is ON, you can be alerted with beeps and a flashing "P. B" or "ë. " · If the direction finding screen is selected, the receiver automatically selects the simple screen when the priority watch starts.
FM
M:A18 145. 765. 000 15. 0
Pause Scan Priority Beep Audio Light A. Power OFF
: 10SEC : OFF : VOLUME : AUTO : OFF
Pause Scan Priority Beep Audio Light A. Power OFF
: 10SEC : ON : VOLUME : AUTO : OFF
Pause Scan Priority Beep Audio Light A. Power OFF
: : : : :
10SEC BELL VOLUME AUTO OFF
TS PRIO
FM 9 RX
PRIO
S1
3
5
7
RX VOL
While pausing on the memory channel, "PRIO" flashes. Priority watch with alert is ON.
u Push [V/M] while the display shows the VFO frequency to stop the watch.
26
PRIORITY WATCH VFO scan watch
q Select the desired memory channel to be watched. 19) r Push [FUNC] + [(MODE) SET] momentarily to enter set mode.
· Select a non-band scope screen in advance for color LCD.
7
u Push [(MODE) SET] to exit set mode and start the watch.
· The receiver checks the memory channel frequency every 5 sec. · The watch resumes according to the selected scan resume condition. 22) · If the priority watch with alert is ON, you can be alerted with beeps and a flashing "P. B" or "ë. " · If the direction finding screen is selected, the receiver automatically selects the simple screen when the priority watch starts.
FM
M:A18 145. 765. 000 15. 0
t Rotate [DIAL] to select "Priority" or "PRIo. "
· "PRIo" disappears after 1 sec. and "oFF" and "PR" appears when color LCD is OFF.
y Push [] or rotate the tuning dial while pushing [FUNC] to select priority watch ON or priority watch ON with alert (BELL).
· If the pocket beep function is activated, the receiver automatically selects the tone squelch function when the priority watch is selected.
TS ALL PRIO
FM 9 RX
PRIO
S1
3
5
7
RX VOL
While pausing on the memory channel, "PRIO" flashes.
Pause Scan Priority Beep Audio Light A. Power OFF
: 10SEC : OFF : VOLUME : AUTO : OFF
Pause Scan Priority Beep Audio Light A. Power OFF
: 10SEC : ON : VOLUME : AUTO : OFF
Pause Scan Priority Beep Audio Light A. Power OFF
: : : : :
10SEC BELL VOLUME AUTO OFF
i Push [V/M] while the display shows the VFO frequency to stop the watch.
Priority watch set mode
Priority watch is ON.
Priority watch with alert is ON.
27
8
SUBAUDIBLE TONE OPERATION
Tone Squelch: OFF Tone Freq. : 88. 5 Duplex : OFF Offset Freq. : 0. 600 Scan Resume : 2SEC Tone Squelch: OFF Tone Freq. : 88. 5 Duplex : OFF Offset Freq. : 0. 600 Scan Resume : 2SEC Tone Squelch: TSQL Tone Freq. : 88. 5 Duplex : OFF Offset Freq. : 0. 600 Scan Resume : 2SEC
I Tone squelch operation
Operation
The tone squelch opens only when receiving a signal containing a matching subaudible tone. You can silently wait for calls from group members using the same tone in an amateur band. w Set the desired subaudible tone in set mode.
· See the following section for programming.
Tone function set mode
Tone squelch OFF
Tone squelch ON
e Push [FUNC] + [(MODE) SET] momentarily to enter set mode.
· Select a non-band scope screen in advance for color LCD.
r Rotate [DIAL] until "Tone Squelch" or "tSqL" appears.
· "tSqL" disappears after 1 sec. [. . . ] · The battery polarity is reversed.
SOLUTION
· Replace the batteries or charge the battery pack. · Turn beep tones ON or set the beep tone level to appropriate level in set mode. · Push [MODE] to select a suitable operating mode.
REF.
pgs. 9
No sound comes from the speaker.
· Volume level is too low. [. . . ]