User manual ICOM IC-M603

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual ICOM IC-M603. We hope that this ICOM IC-M603 user guide will be useful to you.


ICOM IC-M603 : Download the complete user guide (974 Ko)

You may also download the following manuals related to this product:

   ICOM IC-M603 BROCHURE (756 ko)
   ICOM IC-M603 BROCHURE (678 ko)
   ICOM IC-M603 BROCHURE V2011 (7719 ko)
   ICOM IC-M603 BROCHURE (1163 ko)

Manual abstract: user guide ICOM IC-M603

Detailed instructions for use are in the User's Guide.

[. . . ] INSTRUCTION MANUAL VHF MARINE TRANSCEIVER iM603 FOREWORD Thank you for purchasing this Icom transceiver. The IC-M603 VHF MARINE TRANSCEIVER is designed and built with Icom's state of the art technology and craftsmanship. With proper care, this transceiver should provide you with years of trouble-free operation. We want to take a couple of moments of your time to thank you for making the IC-M603 your radio of choice, and hope you agree with Icom's philosophy of "technology first. " Many hours of research and development went into the design of your IC-M603. IMPORTANT READ ALL INSTRUCTIONS carefully and completely before using the transceiver. SAVE THIS INSTRUCTION MANUAL -- This instruction manual contains important operating instructions for the IC-M603. EXPLICIT DEFINITIONS DEFINITION Personal injury, fire hazard or electric shock R WARNING! [. . . ] 1 · A beep tones sounds and "16" blinks when a signal is received on Channel 16 during Priority scan. 5 r To cancel the TAG channel setting, repeat step e. T · "TAG" disappears. Clearing (or setting) all tagged channels While pushing and holding [H/L], push [5· TAG ] for 3 sec. (until a long beep changes to 2 short beeps) to clear all TAG channels setting in the selected channel group. · Repeat above procedure to set all channels as TAG channels. t To stop the scan, push [CLR] or repeat step r. [Example]: Starting a normal scan. 25W INT DUP TAG Push then push Scan starts. INT DUP TAG NORMAL SCAN 34°34. 506N 34 34. 506N 123°23. 236W 123 23. 236W UTC 12:00 12:00 25W When a signal is received BUSY 25W INT TAG NORMAL SCAN 34°34. 506N 34 34. 506N 123°23. 236W 123 23. 236W UTC 12:00 12:00 34°34. 506N 34 34. 506N 123°23. 236W 123 23. 236W UTC 12:00 12:00 INTL SAFETY 15 6 DSC OPERATION I DSC address ID A total of 100 DSC address IDs can be programmed and named with up to 10 characters. I MMSI code programming The 9-digit MMSI (Maritime Mobile Service Identity: DSC self ID) code can be programmed at power ON. q While pushing and holding [MENU], push [POWER] to enter MMSI code programming condition. · Turn power OFF in advance. D Programming Individual ID A q Enter "Add:INDV ID" in DSC Set up menu. D S A DSC Menu Set up Add:INDV ID (Push [MENU]) (Rotate [SELECTOR], then push [ENT]. ) w After the display appears, release [MENU]. D S M DSC Menu Set up MMSI Check (Push [MENU]) (Rotate [SELECTOR], then push [ENT]. ) w Set the individual ID and ID name directly with the keypad. · Edit the 9-digits of the appropriate distress ID directly with the keypad. · Push [CLR] to cancel and exit the condition. --DSC Menu-Add:Individual ID Input 9 digits _________ Input name _________ <CLRExit / ENTOK> r Edit the specific MMSI code directly with the keypad. · Rotate [SELECTOR] to move the cursor backward or forward. --DSC Menu-MMSI Check _________ <CLRExit <CLR Exit / ENT OK> ENTOK> t After entering the 9-digit code, push [ENT] to set the code. · Returns to the DSC set up menu. E y Push [CLR] or rotate [SELECTOR] to select "Exit , " push [ENT] to return to DSC menu. · Repeat again to return to the normal operation condition. e Push [ENT] to program and return to the DSC set up menu. E r Push [CLR] or rotate [SELECTOR] to select "Exit , " push [ENT] to return to DSC menu. · Repeat again to return to the normal operation condition. 16 DSC OPERATION D Deleting Individual ID D q Enter "DEL:INDV ID" in DSC Set up menu. D S D DSC Menu Set up DEL:INDV ID (Push [MENU]) (Rotate [SELECTOR], then push [ENT]. ) N · When no address ID is programmed, "No ID " is displayed. Push [CLR] to exit. 6 --DSC Menu-Add:Group ID Input 8 digits 0________ Input name _________ <CLRExit / ENTOK> w Rotate [SELECTOR] to select the desired ID name for deleting. --DSC Menu-Select ID John Paul George George Michael e Push [ENT] to program and return to the DSC Set up menu. E r Push [CLR] or rotate [SELECTOR] to select "Exit , " push [ENT] to return to DSC menu. · Repeat again to return to the normal operation condition. 6 <CLRExit <CLR Exit / ENTOK> ENT OK> D Deleting Group ID D q Enter "DEL:Group ID" in DSC Set up menu. D S D DSC Menu Set up DEL:Group ID (Push [MENU]) (Rotate [SELECTOR], then push [ENT]. ) N · When no address ID is programmed, "No ID " is displayed. Push [CLR] to exit. e Push [ENT] to delete the selected individual ID and return to the DSC Set up menu. E r Push [CLR] or rotate [SELECTOR] to select "Exit , " push [ENT] to return to DSC menu. · Repeat again to return to the normal operation condition. D Programming Group ID A q Enter "Add:Group ID" in DSC Set up menu. D S A DSC Menu Set up Add:Group ID (Push [MENU]) (Rotate [SELECTOR], then push [ENT]. ) w Set the group ID and ID name directly with the keypad. · Edit the 8-digits of the group ID directly with the keypad. · Push [CLR] to cancel and exit the condition. w Rotate [SELECTOR] to select the desired ID name for deleting. e Push [ENT] to delete the selected group ID and return to the DSC Set up menu. E r Push [CLR] or rotate [SELECTOR] to select "Exit , " push [ENT] to return to DSC menu. · Repeat again to return to the normal operation condition. 17 6 DSC OPERATION I Position and Time programming A Distress call should include the ship's position and time data. If no GPS is connected, your position and UTC (Universal Time Coordinated) time should be input manually. · This manual programming is not available when a GPS receiver (NMEA0183 ver. · Manually programmed position/time data will be held for 23. 5 hours only. P q Enter "Position Input" in DSC menu. D DSC Menu (Push [MENU]) P Position Input (Rotate [SELECTOR], then push [ENT]. ) --DSC Menu-Input Position Latitude __°__. ___N Null Longitude __°__. ___W Null <CENull <CE Null Data> <CLRExit <CLR Exit / ENT OK> ENTOK> e After editing the position data, push [ENT] to set. Then edit the current UTC time with the keypad. · Rotate [SELECTOR] to move the cursor backward or forward. · Push [CLR] to cancel and exit the condition. --DSC Menu-Input UTC Time __:__ Null w Edit your position (latitude and longitude) data directly with the keypad. · Push [6·MNO] to edit N; North latitude or [7·PRS] to edit S; South latitude. [. . . ] The connector of the connection cable can be installed into a cabinet, wall, etc. , as a built-in plug. For longer distance remote operation, the optional extension cable, OPC-1541 (6 m; connecting between transceiver and the connection cable), is available, and up to two OPC-1541 can be added. Do not connect the HM-162E to the OPC-1000. w To use the supplied cable as a wall socket, perform the following steps. e Using the mounting base as a template, carefully mark the holes where the cable and three screws will be fastened. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ICOM IC-M603




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual ICOM IC-M603 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.