User manual ICOM IC-M5

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual ICOM IC-M5. We hope that this ICOM IC-M5 user guide will be useful to you.


ICOM IC-M5 : Download the complete user guide (6752 Ko)

Manual abstract: user guide ICOM IC-M5

Detailed instructions for use are in the User's Guide.

[. . . ] carefully and com- Dual watch and tri-watch functions Convenient functions which allow you to monitor the distress channel (ch 16) while receiving a channel of your choice--dual watch; or monitor the distress channel and another channel while receiving a channel of your choice--tri-watch. With dimensions of 18(H) × 32(W) mm, the IC-M5's function display is easy to read and shows operating conditions at a glance. Backlighting and contrast can be adjusted to suit your preferences. SAVE THIS INSTRUCTION MANUAL--This instruction manual contains important operating instructions for the IC-M5. Large, easy-to-read LCD EXPLICIT DEFINITIONS DEFINITION Personal injury, fire hazard or electric shock RWARNING may occur. WORD Simple operation Ergonomic design with a minimum number of switches and controls provides simple intuitive operation. CAUTIONS RWARNING! [. . . ] w SQUELCH SWITCH [SQL] · Push this switch, then set the squelch level with the UP/DOWN [ ]/[ ] switches. 6) e CHANNEL 16 SWITCH [16 · 9] · Selects channel 16 when pushed. · Enters call channel write mode when the call channel is selected and this switch is pushed for 3 sec. r CHANNEL/WEATHER CHANNEL SWITCH [CH/WX·U/I/C] · Selects and toggles the regular channels and weather channel when pushed momentarily. · Selects one of 3 regular channels in sequence when pushed for 1 sec. 2 t SCAN/TAG SWITCH [SCAN · TAG] · Starts and stops normal or priority scan when tag channels are programmed. · Sets and clears the displayed channel as a tag (scanned) channel when pushed for 1 sec. · While pushing this switch, turn the power ON to clears all tag channels in the selected regular channel group. y TRANSMIT POWER/LOCK SWITCH [H/L · LOCK] · Toggles high and low power when pushed. · Toggles the lock function ON/OFF when t pushed for 1 sec. LO CK VHF MARINE q w e r TRI TAG SQL 9 DW SCAN H/L 16 U / I /C CH / WX u CHANNEL UP/DOWN SWITCHES [ ]/[ ] · Select an operating channel in the selected u channel group. y iM3A PANEL DESCRIPTION 2 I Top and side panels q PTT SWITCH [PTT] Push and hold to transmit; release to receive. squelch level I Lock function This function electronically locks all keys and switches to prevent accidental frequency changes and function access. to turn the lock function ON and OFF. - Only [PTT], [H/L] and [SQL] are functional. q Push [SQL], then select the squelch level with the [ keys. ]/[ ] - There are 11 squelch levels to choose from: OFF is completely open; 10 is the maximum squelch level. - When no key pushes within 5 sec. , the display returns to normal indication. w Push [SQL] once more when the desired squelch level is indicated in the function display. - The display returns to normal indication. Appears when the lock function is in use. USA 6 BASIC OPERATION 3 I Receiving and transmitting CAUTION: Transmitting without an antenna may damage the transceiver. q Rotate [OFF/VOL] clockwise to turn power ON, then set to the 10 o'clock position. - Use the squelch function to mute any audio noise if necessary. Refer to the previous page for details. IMPORTANT: To maximize the readability of your transmitted signal, pause a few sec. after pushing [PTT], hold the microphone 5 to 10 cm (2 to 4 inches) from your mouth and speak at a normal voice level. of inactivity. TAG USA 8 DUALWATCH/TRI-WATCH I Description Dualwatch monitors channel 16 while you are receiving another channel; tri-watch monitors channel 16 and the call channel while receiving another channel. DUALWATCH/TRIWATCH SIMULATION Call channel 4 I Operation q Select the desired operating channel. w Push [DW · TRI] momentarily to start dualwatch; push [DW · TRI] for 1 sec. to start tri-watch. - "DUAL" flashes during dualwatch; "TRI" flashes during tri-watch. - Tri-watch becomes dualwatch when receiving a signal on the call channel. [. . . ] When OFF is selected, the scan pauses until a received signal disappears. after receiving a signal and then resumes even if the signal is still being received. Scan timer OFF (default) Weather alert function OFF (default) D Scan type selection "SC" The transceiver has 2 scan types: normal scan and priority scan. Priority scan searches all tag channels in sequence while monitoring channel 16. D Auto power save function "PS" The power save function reduces current drain by deactivating the receiver circuit for preset intervals. Power save ON (default) Normal scan (default) Priority scan 13 7 BATTERY CHARGING I Battery charging Prior to using the transceiver for the first time, the Ni-Cd batteries must be fully charged for optimum life and operation. I Installing batteries in the battery case When using a battery case attached to the transceiver, install 6 AA(R6) size Ni-Cd or alkaline batteries as illustrated below. CAUTION: · When installing batteries, make sure they are all the same brand, type and capacity. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ICOM IC-M5




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual ICOM IC-M5 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.