User manual ICOM IC-M402S

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual ICOM IC-M402S. We hope that this ICOM IC-M402S user guide will be useful to you.


ICOM IC-M402S : Download the complete user guide (5241 Ko)

You may also download the following manuals related to this product:

   ICOM IC-M402S INSTRUCTION MANUAL (1979 ko)

Manual abstract: user guide ICOM IC-M402S

Detailed instructions for use are in the User's Guide.

[. . . ] It is equivalent to IPX7 waterproofing. * (* except cables) 1m depth for 30 minutes Large LCD with dot-matrix characters The large full dot-matrix display is designed for optimum readability in any lighting condition. With the extra large font, the channel number is maximized on the display and upper and lower case characters can be easily read. Built-in ITU Class-D DSC No matter what channel you're tuned to, a separate and independent receiver inside the IC-M402S continuously monitors Ch. [. . . ] The 10-keypad allows simple and efficient operation of the DSC emergency functions, vital for your safety at sea. Position request and position report Over and above the DSC, your own and other ships' position data can be exchanged with the position request or position report functions. The received position information can be transferred to external GPS or navigation equipment*. In addition, the polling (request/ reply) function checks whether a specific ship is within the communications range. * NMEA 0183 format is required. A GPS information example on 37×73mm size display 30 Watt 2-way hailer capability When connected to an external hailer horn, communication with other boats, deck or dock hands is easy. The built-in 30W amplifier increases your talk power making your message loud and clear. Four fog horn patterns are available for the automatic fog horn, adding further to the safety of the ship. Improved GPS information indication When connecting to an external GPS receiver, the GPS information indication function shows course and speed data as well as position, date and time on the display. on VHF marine ANDMICIIIs TM TM Optional fully integrated Commandmic VHF MARINE TRANSCEIVER Front and rear panel microphone connection The speaker microphone can be detached from the front panel and can be connected to the rear panel without any modification. An optional 6. 1m (20ft) microphone extension cable, OPC1000, is available. Transparent installation image Up to two COMMANDMICIIIsTM can be connected The optional COMMANDMICIIITM provides a 2nd and/or 3rd station capability to operate the IC-M402S from up to 18. 3m* (60ft) away such as the cabin and/or fly bridge. * Requires use of two optional OPC-1541 extension cables. Full control and intercom capability On the deck RX speaker function The RX speaker function, "receiver-repeater" allows you to monitor the received radio audio from a hailer horn on the deck or tower. You can also make an announcement onboard from the microphone. All functions of the IC-M402S, including distress call, DSC, and hailer, are available. Military Specifications The IC-M402S and HM-162E have been tested to and passed the following MIL-STD requirements and strict environmental standards. Standard Low Pressure High Temp. Shock Solar Radiation Rain Humidity Salt Fog Dust Blowing Vibration Shock MIL 810 C MIL 810 D Method Proc. 500. 1 I 500. 2 I, II 501. 1 I 501. 2 I, II 502. 1 I 502. 2 I, II 503. 1 I 503. 2 I 505. 1 I 505. 2 I 506. 1 I, II 506. 2 I, II 507. 1 I, II 507. 2 II, III 509. 1 I 509. 2 I 510. 1 I 510. 2 I 514. 2 VIII, X 514. 3 I 516. 2 I, II, V 516. 3 I, IV MIL 810 E Method Proc. 500. 3 I, II 501. 3 I, II 502. 3 I, II 503. 3 I 505. 3 I 506. 3 I, II 507. 3 II, III 509. 3 I 510. 3 I 514. 4 I 516. 4 I, IV MIL 810 F Method Proc. 500. 4 I, II 501. 4 I, II 502. 4-3 I, II 503. 4 I 505. 4 I 506. 4 I, III 507. 4 ­ 509. 4 ­ 510. 4 I 514. 5 I 516. 5 I, IV · HM-162E REMOTE-CONTROL MICROPHONE Size (W×H×D): 65. 5×150×38 mm Weight (approx. ;except cables): 385g Supplied accessories : · 6. 1m of cable, OPC-1540, with external speaker terminal · Microphone hanger · Mounting base for cable connector DO NOT connect the HM-134B to the IC-M402S as this may damage the transceiver. HM-134B COMMANDMICTM is NOT compatible with the IC-M402S. · OPC-1541 EXTENSION CABLE FOR HM-162E 6. 1m of extension cable for additional separation length when using the COMMANDMICIIITM. · OPC-1000 MICROPHONE EXTENSION CABLE 6. 1m extension cable with mounting base for use with rear panel microphone connection. COMMANDMIC is a registered trademark of Icom Inc. [. . . ] HM-134B COMMANDMICTM is NOT compatible with the IC-M402S. · OPC-1541 EXTENSION CABLE FOR HM-162E 6. 1m of extension cable for additional separation length when using the COMMANDMICIIITM. · OPC-1000 MICROPHONE EXTENSION CABLE 6. 1m extension cable with mounting base for use with rear panel microphone connection. COMMANDMIC is a registered trademark of Icom Inc. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ICOM IC-M402S




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual ICOM IC-M402S will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.