User manual ICOM IC-M402

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual ICOM IC-M402. We hope that this ICOM IC-M402 user guide will be useful to you.


ICOM IC-M402 : Download the complete user guide (5241 Ko)

You may also download the following manuals related to this product:

   ICOM IC-M402 SCHABLONE (36 ko)
   ICOM IC-M402 BROCHURE (631 ko)
   ICOM IC-M402 AUTRE NOTICE (1022 ko)

Manual abstract: user guide ICOM IC-M402

Detailed instructions for use are in the User's Guide.

[. . . ] This radio has been evaluated for compliance at the distance of 2. 5 cm with the FCC RF exposure limits for "Occupational Use Only". In addition, your Icom radio complies with the following Standards and Guidelines with regard to RF energy and electromagnetic energy levels and evaluation of such levels for exposure to humans: · FCC OET Bulletin 65 Edition 97-01 Supplement C, Evaluating Compliance with FCC Guidelines for Human Exposure to Radio Frequency Electromagnetic Fields. · American National Standards Institute (C95. 1-1992), IEEE Standard for Safety Levels with Respect to Human Exposure to Radio Frequency Electromagnetic Fields, 3 kHz to 300 GHz. · American National Standards Institute (C95. 3-1992), IEEE Recommended Practice for the Measurement of Potentially Hazardous Electromagnetic Fields­ RF and Microwave. [. . . ] Indication Battery level Full Middle Charging required No battery !8 !7 blinks when the battery over charged. 16) "DUAL" appears during dualwatch; "TRI" appears during tri-watch. !0 SUB CHANNEL READOUT · Indicates Channel 16 during priority scan, dualwatch or tri-watch. w BUSY INDICATOR Appears when receiving a signal or when the squelch opens. 8) Appears when the call channel is selected. 6 PANEL DESCRIPTION 3 !1 SQUELCH LEVEL INDICATOR Shows the squelch level. !3 VOLUME LEVEL ADJUSTING INDICATOR Blinks while adjusting the volume level. !4 SQUELCH LEVEL ADJUSTING INDICATOR Blinks while adjusting the squelch level. !5 CHANNEL NUMBER READOUT · Indicates the selected operating channel number. 9) "U" appears when U. S. A. ; "I" appears when International; "C" appears when Canadian channel group is selected. 9) · "WX" appears when the weather channel group is selected. · "ALT" appears while the weather alert function is activated; blinks when the alert tone is received. !8 LOW POWER INDICATOR (p. · While pushing both [SQL·MONI] and [+], turn the power ON to set [+]/[­] to the squelch level adjustment key. 10 BASIC OPERATION 4 I Receiving and transmitting CAUTION: Transmitting without an antenna may damage the transceiver. q Push and hold [PWR] to turn power ON. Push [SQL·MONI] to stop "SQL" indicator blinking, then push [+]/[­] to set the volume level. Push [SQL·MONI], and push [+]/[­] to set the squelch level. e Push [Y]/[Z] to select the desired channel. - When receiving a signal, " " appears and audio is emitted from the speaker. - Further adjustment of the volume may be necessary at this point. IMPORTANT: To maximize the readability of your transmitted signal, pause a few sec. after pushing [PTT], hold the microphone 5 to 10 cm (2 to 4 inches) from your mouth and speak into the microphone at a normal voice level. NOTE: The transceiver has a power save function to conserve the battery power. The power save function activates automatically when no signal is received for 5 sec. For U. S. A version: To prevent accidental prolonged transmission, etc. , the IC-M402 has a time-out timer function. of continuous transmission. 4 r Push [H/L·LOCK] to select the output power if necessary. - "LOW" appears when low power is selected; no indication when high power is selected. [. . . ] w Connect the plugs of the BC-119N/121N to the AD-103 desktop charger adapter with the connector, then install the adapter into the charger with the supplied screws. Desktop charger adapter Connector Screws supplied with the charger adapter 8 Not used Plug 25 8 BATTERY CHARGING ï Rapid charging with the BC-121N+AD-103 The optional BC-121N allows up to 6 battery packs to be charged simultaneously. · Six AD-103 charger adapters · An AC adapter (BC-124) or the DC power cable (OPC-656) IC-M402 BP-224 ï Rapid charging with the BC-119N+AD-103 The optional BC-119N provides rapid charging of battery packs. · AD-103 charger adapter · An AC adapter (may be supplied with BC-119N depending on version) or the DC power cable (OPC-515L/CP-17L). IC-M402 BP-224 AC adapter (Purchase separately) AD-103 charger adapter is installed in BC-119N. AC adapter (Not supplied with some versions. ) AD-103 charger adapters are installed in each slot. Optional OPC-515L (for 13. 8 V power source) or CP-17L (for 12 V cigarette lighter socket) can be used instead of the AC adapter. DC power cable (OPC-656) (Connect with the DC power supply; 13. 8 V/at least 7 A) 26 SWIVEL BELT CLIP I MB-87 contents Qty. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ICOM IC-M402




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual ICOM IC-M402 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.