User manual ICOM IC-M35

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual ICOM IC-M35. We hope that this ICOM IC-M35 user guide will be useful to you.


ICOM IC-M35 : Download the complete user guide (1686 Ko)

You may also download the following manuals related to this product:

   ICOM IC-M35 BROCHURE (1367 ko)
   ICOM IC-M35 BROCHURE (788 ko)
   ICOM IC-M35 BROCHURE V2011 (4888 ko)
   ICOM IC-M35 BROCHURE (475 ko)

Manual abstract: user guide ICOM IC-M35

Detailed instructions for use are in the User's Guide.

[. . . ] INSTRUCTION MANUAL VHF MARINE TRANSCEIVER iM35 DOC CE versions of the IC-M35 which display the "CE" symbol on the serial number seal, comply with the essential requirements of the European Radio and Telecommunication Terminal Directive 1999/5/EC. This warning symbol indicates that this equipment operates in non-harmonised frequency bands and/or may be subject to licensing conditions in the country of use. Be sure to check that you have the correct version of this radio or the correct programming of this radio, to comply with national licensing requirement. DECLARATION OF CONFORMITY We Icom Inc. Japan 1-1-32, Kamiminami, Hirano-ku Osaka 547-0003, Japan Declare on our sole responsability that this equipment complies the essential requirements of the Radio and Telecommunications Terminal Equipment Directive, 1999/5/EC, and that any applicable Essential Test Suite measurements have been performed. [. . . ] to activate the volume mute function. · The volume level is set to the minimum level (OFF). · The volume level indicator blinks. w Push [VOL/SQL MONI] again to exit the squelch adjustment mode. Indicates the squelch level. Blinks while adjusting the squelch level. w Push [LOUD MUTE] again, or push [VOL/SQL MONI] to turn the volume mute function OFF. 12 BASIC OPERATION 4 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Lock function This function electronically locks all keys (except for [PTT], [VOL/SQL MONI], [LOUD MUTE], [Hi/Lo ] and [Y]/[Z]*) to prevent accidental channel changes and function access. to turn the lock function ON and OFF. Appears while the lock function is activated. Automatic backlighting This function lights the function display and keys, and it is convenient for night-time operation. 19) Push any key except for [PTT] to turn the backlight ON. · The backlight is automatically turned OFF after 5 sec. of inactivity. AquaQuake water draining function The AquaQuake water draining function clears water away from the speaker grill. Without this function, water may muffle the sound coming from the speaker. The transceiver emits a vibrating beep when this function is activated. Push and hold both [SCAN DUAL] and [Hi/Lo ]. · A low beep tone sounds for 9 sec. · The transceiver never accepts key operation while the AquaQuake function is activated. · The AquaQuake function can not be activated when an optional speaker-microphone is connected. Push and hold for 1 sec. Monitor function The monitor function opens the squelch. 19) The monitor function is activated by pushing and holding [VOL/SQL MONI] for 1 sec. ·" " blinks and the squelch is opened. Blinks while the monitor function is activated. Push and hold for 1 sec. 13 5 SCAN OPERATION (Except Holland version) Scan types Scanning is an efficient way to locate signals quickly over a wide frequency range. In addition, the auto scan function is available for standby convenience. This function can be activated depending on the setting in the set mode. 18) PRIORITY SCAN CH 01 CH 02 Set the TAG channels (scanned channels) before scanning. Clear the TAG for unwanted channels which inconveniently stop scanning, such as those for digital communications. 15) Choose the desired scan type from "Priority" or "Normal" in the set mode. 18) NORMAL SCAN CH 01 CH 02 CH 88 CH 16 CH 03 CH 88 CH 03 CH 05 CH 04 CH 05 CH 04 Priority scan searches through all TAG channels in sequence while monitoring Channel 16. When a signal is detected on Channel 16, scan pauses until the signal disappears; when a signal is detected on a channel other than Channel 16, scan becomes Dualwatch until the signal disappears. Normal scan, like priority scan, searches through all TAG channels in sequence. However, unlike priority scan, Channel 16 is not checked unless Channel 16 is set as a TAG channel. 14 SCAN OPERATION 5 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Setting TAG channels For more efficient scanning, add the desired channels as TAG channels or clear TAG for unwanted channels. TAG channels can be assigned to each channel group (U. S. A. , International and ATIS) independently. [. . . ] NOTE: The microphone is located at the top of the speaker-microphone, as shown above. To maximize the readability of your transmitted signal (voice), hold the microphone approx. NOTE: When the speaker-microphone is connected to the transceiver, the noise cancellation does not work. Attaching: Attach the [SP MIC] cap (q), then rotate it clockwise completely (w). 3 PROBLEM The transceiver does not turn · The battery is exhausted. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ICOM IC-M35




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual ICOM IC-M35 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.