User manual ICOM IC-F33GT-GS

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual ICOM IC-F33GT-GS. We hope that this ICOM IC-F33GT-GS user guide will be useful to you.


ICOM IC-F33GT-GS : Download the complete user guide (884 Ko)

You may also download the following manuals related to this product:

   ICOM IC-F33GT-GS annexe 1 (927 ko)

Manual abstract: user guide ICOM IC-F33GT-GS

Detailed instructions for use are in the User's Guide.

[. . . ] INSTRUCTION MANUAL VHF TRANSCEIVER UHF TRANSCEIVER iF33GT/GS iF43GT/GS This device complies with Part 15 of the FCC Rules. Operation is subject to the condition that this device does not cause harmful interference. IMPORTANT READ ALL INSTRUCTIONS carefully and completely before using the transceiver. PRECAUTION R CAUTION!NEVER hold the transceiver so that the antenna is very close to, or touching exposed parts of the body, especially the face or eyes, while transmitting. (5 to 10 cm) away from the lips and the transceiver is vertical. SAVE THIS INSTRUCTION MANUAL -- This instruction manual contains important operating instructions for the IC-F33GT/GS VHF TRANSCEIVER and IC-F43GT/GS UHF TRANSCEIVER. R CAUTION! [. . . ] · " " appears or blinks depending on the setting. I Default setting The following functions are assigned to each programmable key as the default. [P0]; Call : Push to transmit a 5-tone/BIIS call when the selected channel is a 5tone or MSK channel, respectively. [P1]; Digital : Push to select the call list ID/transmit message, or to display the receive message record for selection. [P3]; TX Code Enter : Push to enter the direct ID code edit mode for both 5-tone and MSK. [UP]/[DOWN]; CH Up/Down : While in the standby condition, selects the operating channel. After pushing [Digital] or [TX Code CH Select], selects call list or TX code channel, respectively. [MONITOR]; Moni(Audi): Push this key after the communication to send a `Clear down' signal during MSK channel operation. [P2]/[RED]; Null : No function is assigned. Appears Appears or blinks w Push and hold [PTT], then speak into the microphone at a normal voice level. ·" ·" " indicator appears. " appears while receiving a signal. e Release [PTT] to return to receive. r To finish the conversation, push [MONITOR] (Moni(Audi)) to send the `Clear down' signal. · Either station can send a `Clear down' signal. · " " disappears and the transceiver returns to the standby condition. 16 BIIS OPERATION 4 D Group call q When a group call is received; · Beeps sound. · The programmed text message (e. g. " ") and the calling station ID (or text) is displayed alternately, depending on the setting. · " " appears or blinks depending on the setting. D Displaying the received call record -- Queue indication The transceiver memorizes the calling station IDs for record. Up to 3 calls can be memorized, and the oldest call record is erased when a 4th call is received. However, once the transceiver is powered OFF, the all records are cleared. q Push [P1] (Digital) for 1 sec. · Displays following indication. When a record is available Appears Appears or blinks When no record is available w Push and hold [PTT], then speak into the microphone at a normal voice level. NOTE: Only one station is permitted to speak. ·" ·" " appears. " appears while receiving a signal. e Release [PTT] to return to receive. r To finish the conversation, push [MONITOR] (Moni(Audi)) to send the `Clear down' signal. · Either station can send a `Clear down' signal. (approx. ) · " " disappears and the transceiver returns to the standby condition. w Push [UP] or [DOWN] to select the desired call. again to return to the standby condition. · When no operation is performed for 30 sec. , the transceiver returns to the standby condition automatically. 17 4 BIIS OPERATION I Transmitting a call Total of a 3 ways for code selection are available--selecting the call code from memory, entering the call code from the keypad and calling back from the queue channel record. D Calling back from the queue channel q While in the standby condition, push [P1] (Digital) for 1 sec. w Push [UP] or [DOWN] to select the desired record. D Using call memory q While in the standby condition, push [P1] (Digital) to enter the call code memory channel selection mode. ·" " appears. [. . . ] · HS-94/HS-95/HS-97 HEADSET + VS-1L VOX/PTT CASE HS-94: Ear-hook type HS-95: Neck-arm type HS-97: Throat microphone VS-1L: VOX/PTT switch box for hands-free operation, etc. Frequency range: 450­490 MHz · FA-SC56VS STUBBY ANTENNA Shorter VHF antenna. Frequency range: 150­162 MHz · FA-SC57VS STUBBY ANTENNA Shorter VHF antenna. Frequency range: 160­174 MHz Some options may not available in some countries. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ICOM IC-F33GT-GS




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual ICOM IC-F33GT-GS will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.