User manual ICOM IC-A21

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual ICOM IC-A21. We hope that this ICOM IC-A21 user guide will be useful to you.


ICOM IC-A21 : Download the complete user guide (3259 Ko)

Manual abstract: user guide ICOM IC-A21

Detailed instructions for use are in the User's Guide.

[. . . ] NEVER operate the transceiver with a EXPLICIT DEFINITIONS The explicit definitions below apply to this instruction manual. DEFINITION Personal injury, fire hazard or electric shock RWARNING may occur. If you experience a ringing in your ears, reduce the volume level or discontinue use. NEVER connect the transceiver to an AC outlet or to a power source of more than 14 V DC. NEVER connect the transceiver to a power source that is DC fused at more than 5 A. [. . . ] w Push [CLR] to exit from the emergency frequency. s Setting a frequency ï Using keypad q Push [PWR] for 0. 5 sec. to turn power ON, then push [CLR] to select the frequency mode when memory CH number or WX CH number appears on the function display. · When a digit is mistakenly input, push [CLR] to clear, then start again. · Only [2], [5], [7] and [0] can be entered as the 5th and final digit. version has VHF marine WX (weather) channel receiving capability for flight planning. q Push , then push [ENT (WX)] to select WX channel mode. · "WX--" and previously selected channel number appears. s Side tone function When using an optional headset, such as those from the David Clark Co. via the OPC-967 HEAD SET ADAPTOR, the transceiver outputs your transmitted voice to the headset for monitoring. 32) D Setting the side tone level q Push [PTT] to turn the transmit mode ON. w During transmit mode, push [Y]/[Z] several times to adjust the monitoring level. NEVER operate the transceiver with a headset at high volume levels for long period. If so, reduce the monitor level or discontinue use. w Rotate the [DIAL] to select the desired WX channel. 12 MEMORY OPERATION 4 s Programming a memory channel The transceiver has 200 (10 BANK x 20 CH) memory channels for storage of often-used frequencies. w Select the desired frequency. · Push , then push [ENT (WX)] to select a weather channel. * · Set the desired frequency or WX channel* using the [DIAL] or keypad. · EXAMPLE: Programming WX-05* into memory BANK 3/ memory channel 2. then [0], [5] or [5] [ENT] e Push , then push [MR (MW)]. then · Memory BANK and memory channel number appears. r Rotate the [DIAL] to select the desired memory channel number. · [M] blinks. [3] or t Push [ENT] to program the information into the channel and return to Frequency mode. *Weather channel: U. S. A. version only. [0], [2] or [2] then [ENT] 13 4 MEMORY OPERATION s Memory names ï Programming memory names The memory channel can display a 6-character comment as well as a frequency. q Rotate the [DIAL] to select the desired frequency in Frequency mode. e Rotate the [DIAL] to select the desired memory channel to be programmed. · Push [BANK] to select the BANK number if desired. Push [CLR] to exit the BANK selection mode. key Character 1 4 7 1, Q, Z 4, G, H, I 7, P, R, S key Character 2 5 8 0 2, A, B, C 5, J, K, L 8, T, U, V 0, space ­ key Character 3 6 9 3, D, E, F 6, M, N, O 9, W, X, Y ENT Program ï Clearing memory contents Unwanted memory channels can be cleared. Programming over a memory channel also clears the previously programmed contents. · "-- -- -- -- -- --" appears momentarily, then the next selectable channel appears. r Push [MR] to enter the memory name programming mode. · "-- -- -- -- -- -- " appears on the display. t Push the appropriate digit key several times to select the desired character as listed at right. · To erase a character, overwrite with a space (displayed as _). · To move the cursor forwards or backwards, use [DIAL]. y Push [ENT] to program the name. · Flashing stops. · When no name is programmed, the display shows the operating frequency. [. . . ] 9) CS-A23 CLONING SOFTWARE Provides quick and easy programming of items, including private channels, scan settings, etc. , via an IBM® compatible PC to transceiver. OPC-474 CLONING CABLE Cloning cable for transceiver to transceiver cloning. OPC-478 CLONING CABLE Cloning cable for PC to transceiver cloning. BP-200L 1 9. 6 V 760 mAh 6 hrs Operating periods are calibrated for the following conditions: at 25°C (77°F), Tx (high power) : Rx : standby = 5 : 5 : 90 D Other options BC-110A WALL CHARGER (same as supplied. Depends on version) Used for regular charging of the connected battery pack. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ICOM IC-A21




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual ICOM IC-A21 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.