User manual ICOM IC-775DSP MAINTENANCE

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual ICOM IC-775DSP MAINTENANCE. We hope that this ICOM IC-775DSP MAINTENANCE user guide will be useful to you.


ICOM IC-775DSP MAINTENANCE : Download the complete user guide (1133 Ko)

Manual abstract: user guide ICOM IC-775DSP MAINTENANCE

Detailed instructions for use are in the User's Guide.

[. . . ] We would like to take a few moments of your time to thank you for making the IC-775DSP MAINTENANCE your radio of choice, and hope you agree with Icom's philosophy of "technology first. " Many hours of research and development went into the design of your IC-775DSP MAINTENANCE. D FEATURES Ultimate receiver performance: third-order intercept (IP3) of +40 dBm (HF bands only), both main and sub Independent identical receiver circuits for main and sub bands provide perfect no-compromise Dualwatch operation Built-in Baudot RTTY and PSK31 modulator/demodulator and direct PC keyboard connection capability for RTTY and PSK31 operation without a PC Upgraded real-time spectrum scope-- center frequency and fix frequency modes, plus mini-scope displays IMPORTANT READ THIS INSTRUCTION MANUAL CAREFULLY before attempting to operate the transceiver. SAVE THIS INSTRUCTION MANUAL. This manual contains important safety and operating instructions for the IC-775DSP MAINTENANCE. EXPLICIT DEFINITIONS WORD R WARNING CAUTION NOTE DEFINITION Personal injury, fire hazard or electric shock may occur. No risk of personal injury, fire or electric shock. TRADEMARKS Icom, Icom Inc. and the logo are registered trademarks of Icom Incorporated (Japan) in the United States, the United Kingdom, Germany, France, Spain, Russia and/or other countries. i PRECAUTIONS R WARNING HIGH RF VOLTAGE! [. . . ] ·" " displays the marker at the sub readout frequency. · "<<" or ">>" appears when the marker is out of range. · The spectrum scope shows the transmit signal waveform while transmitting. 5-4) · The spectrum scope shows the peak level holding function. Peak levels are displayed in the background of the current spectrum in a different color until the receive frequency changes. This can be deactivated and the waveform color can be set in scope set mode. 5-5) · Observed indication example i Push [F-4·HOLD] to freeze the current spectrum waveform. · " HOLD " appears while the function is in use. · The peak hold function can be deactivated in scope set mode. o Push [EXIT/SET] to exit the scope screen. Push [F-2·ATT] several times to activate the spectrum scope attenuator in this case. They are generated in the internal scope circuit and do not indicate a transceiver malfunction. 5-2 FUNCTIONS FOR RECEIVE 5 D Fix mode Displays signals within the specified frequency range. The selected frequency band conditions can be observed at a glance when using this mode. [F-2·ATT] [F-4·HOLD] [F-5·CENT/FIX] q Push [EXIT/SET] several times to close a multifunction screen, if necessary. · The set color is indicated in the box beside the RGB scale. Select the sweeping speed for the ±2. 5 kHz span selection from SLOW, MID and FAST. NOTE: The waveform may be displayed incorrectly with "FAST" setting. Select the sweeping speed for the ±5 kHz span selection from SLOW, MID and FAST. NOTE: The waveform may be displayed incorrectly with "FAST" setting. Select the sweeping speed for the ±10 kHz span selection from SLOW, MID and FAST. Select the sweeping speed for the ±25 kHz span selection from SLOW, MID and FAST. 5-5 5 FUNCTIONS FOR RECEIVE D Scope set mode (continued) Select the sweeping speed for the ±50 kHz span selection from SLOW, MID and FAST. Select the sweeping speed for the ±100 kHz span selection from SLOW, MID and FAST. Select the sweeping speed for the ±250 kHz span selection from SLOW, MID and FAST. Set the scope edge frequencies for fix mode scope with below 1. 6 MHz band selection. · Set the frequencies within 0. 030 to 1. 600 MHz range in 1 kHz steps. Up to 500 kHz band width can be specified, so either edge frequency will be set to the difference between higher and lower frequencies become 5 to 500 kHz automatically while setting another edge frequency. Set the scope edge frequencies for fix mode scope when 1. 6 to 2 MHz band is selected. · Set the frequencies within 1. 600 to 2. 000 MHz range in 1 kHz steps. Set the scope edge frequencies for fix mode scope when 2 to 6 MHz band is selected. · Set the frequencies within 2. 000 to 6. 000 MHz range in 1 kHz steps. Up to 500 kHz band width can be specified, so either edge frequency will be set to the difference between higher and lower frequencies become 5 to 500 kHz automatically while setting another edge frequency. Set the scope edge frequencies for fix mode scope when 6 to 8 MHz band is selected. · Set the frequencies within 6. 000 to 8. 000 MHz range in 1 kHz steps. Up to 500 kHz band width can be specified, so either edge frequency will be set to the difference between higher and lower frequencies become 5 to 500 kHz automatically while setting another edge frequency. 5-6 FUNCTIONS FOR RECEIVE 5 D Scope set mode (continued) Set the scope edge frequencies for fix mode scope when 8 to 11 MHz band is selected. · Set the frequencies within 8. 000 to 11. 000 MHz range in 1 kHz steps. Up to 500 kHz band width can be specified, so either edge frequency will be set to the difference between higher and lower frequencies become 5 to 500 kHz automatically while setting another edge frequency. Set the scope edge frequencies for fix mode scope when 11 to 15 MHz band is selected. · Set the frequencies within 11. 000 to 15. 000 MHz range in 1 kHz steps. Up to 500 kHz band width can be specified, so either edge frequency will be set to the difference between higher and lower frequencies become 5 to 500 kHz automatically while setting another edge frequency. Set the scope edge frequencies for fix mode scope when 15 to 20 MHz band is selected. · Set the frequencies within 15. 000 to 20. 000 MHz range in 1 kHz steps. Up to 500 kHz band width can be specified, so either edge frequency will be set to the difference between higher and lower frequencies become 5 to 500 kHz automatically while setting another edge frequency. Set the scope edge frequencies for fix mode scope when 20 to 22 MHz band is selected. · Set the frequencies within 20. 000 to 22. 000 MHz range in 1 kHz steps. Up to 500 kHz band width can be specified, so either edge frequency will be set to the difference between higher and lower frequencies become 5 to 500 kHz automatically while setting another edge frequency. Set the scope edge frequencies for fix mode scope when 22 to 26 MHz band is selected. · Set the frequencies within 22. 000 to 26. 000 MHz range in 1 kHz steps. Up to 500 kHz band width can be specified, so either edge frequency will be set to the difference between higher and lower frequencies become 5 to 500 kHz automatically while setting another edge frequency. 5-7 5 FUNCTIONS FOR RECEIVE D Scope set mode (continued) Set the scope edge frequencies for fix mode scope when 26 to 30 MHz band is selected. · Set the frequencies within 26. 000 to 30. 000 MHz range in 1 kHz steps. [. . . ] t Push [F-3· ] to select the desired part then rotate main dial to set the desired or specified IP address. · "192. 168. 0. 1" is the default setting. y Push [F-2·Z] to select "Subnet Mask" item. u Rotate main dial to set the desired or specified subnet mask. · "255. 255. 255. 0" is the default setting. i Push [POWER] to turn the transceiver power OFF, then ON to effect the IP address and subnet mask settings. 16-7 16 UPDATING THE FIRMWARE D Updating from the PC q Start up the IC-775DSP MAINTENANCE Firm Utility. · The window as at left appears. w Read the caution in the window carefully. e Click [Yes] if you agree and continue the firmware updating. Click to continue r Select the firmware file, that has "dat" extension (e. g. : 7800_110. dat). Click [. . . ] to select the firmware file. t Type the IC-775DSP MAINTENANCE's IP address into "IC-775DSP MAINTENANCE IP Address" text box. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ICOM IC-775DSP MAINTENANCE




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual ICOM IC-775DSP MAINTENANCE will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.