User manual ICOM IC-7000

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual ICOM IC-7000. We hope that this ICOM IC-7000 user guide will be useful to you.


ICOM IC-7000 : Download the complete user guide (4148 Ko)

You may also download the following manuals related to this product:

   ICOM IC-7000 (6414 ko)
   ICOM IC-7000 BROCHURE (391 ko)
   ICOM IC-7000 BROCHURE (149 ko)
   ICOM IC-7000 ANNEXE 97 (2679 ko)
   ICOM IC-7000 ANNEXE 183 (1445 ko)
   ICOM IC-7000 BROCHURE (1694 ko)
   ICOM IC-7000 ANNEXE 1 (335 ko)
   ICOM IC-7000 SERVICE MANUAL (10942 ko)
   ICOM IC-7000 INSTRUCTION MANUAL (4136 ko)

Manual abstract: user guide ICOM IC-7000

Detailed instructions for use are in the User's Guide.

[. . . ] INSTRUCTION MANUAL i7000 HF/VHF/UHF ALL MODE TRANSCEIVER IMPORTANT READ THIS INSTRUCTION MANUAL CAREFULLY before attempting to operate the transceiver. EXPLICIT DEFINITIONS WORD R WARNING CAUTION NOTE DEFINITION Personal injury, fire hazard or electric shock may occur. No risk or personal injury, fire or electric shock. SAVE THIS INSTRUCTION MANUAL. This manual contains important safety and operating instructions for the IC-7000. FOREWORD We understand that you have a choice of many different radios in the market place. We want to take a couple of moments of your time to thank you for making the IC-7000 your radio of choice, and hope you agree with Icom's philosophy of "technology first. " Many hours of research and development went into the design of your IC-7000. SUPPLIED ACCESSORIES The transceiver comes with the following accessories. [. . . ] ·" " appears. Appears Selected M3, then 4 TON push Rotate !3 Select M-2, then push and hold [F-2 MW] for 1 sec. to store the contents in the selected memory channel. Select Selected M2, then MW push 66 4 RECEIVE AND TRANSMIT 1750 Hz tone burst A 1750 Hz tone is required to access most European repeaters. While pushing and holding [PTT], push [F-3 TON] in the M-1 display during repeater operation. 63, 66) Popup indication appears. [MENU/GRP] [F-3] NOTE: This function is not available for non-European versions. DTMF memory encoder DTMF tones are used for autopatching, controlling other equipment, etc. The transceiver has 4 DTMF memory channels (D1­D4) for storage of often-used DTMF codes sequence of up to 24 digits. D DTMF send menu To transmit a DTMF code using a DTMF send menu, program the desired code in advance as described on next page. [MODE] · Transmitting q Select FM mode with [MODE]. · Push [MENU/GRP] momentarily one or more times to select the menu S-1. e Push [F-2 DTM] to enter the DTMF send menu. · If the DTMF root menu appears, push [F-1 SND]. The DTMF starting menu can be changed in the miscellaneous (others) set mode (see p. [MENU/GRP] [F-1] [F-2] [F-3] [F-4] r Push [F-1 D1] -- [F-4 D4] to transmit the DTMF code. D D · "D1"­ "D4" are highlighted while transmitting. See next page for DTMF set mode. · DTMF send menu Z t Push [Z(MENU/GRP)] twice to exit DTMF send menu and return to the normal FM mode display. DTMF code sequence 67 RECEIVE AND TRANSMIT 4 D Programming a DTMF code q Push [MODE] to select FM mode. · Push [MENU/GRP] momentarily one or more times to select the menu S-1. Z e Push [F-2 DTM] then [Z(MENU/GRP)] to select the DTMF root menu. · If the DTMF root menu appears, skip pushing Z [Z(MENU/GRP)]. The DTMF starting menu can be changed in the miscellaneous (others) set mode. 134) [MENU/GRP] [F-1] [F-2] [F-3] [F-4] [DIAL] r Push [F-2 EDT] to enter the DTMF edit menu. t Push [F-1 D1 ] -- [F-4 D4 ] to select the desired DTMF memory channel. y Select the desired code by rotating [DIAL]. · Push [F-1 Å] or [F-2 Ç] for cursor movement. · Push [F-3 DEL] to delete the selected code. u Repeat steps t and y until the desired contents are input. Z i Push [Z(MENU/GRP)] to return to memory channel selection mode, then select the next memory channel and repeat steps t and u for code input, if desired. Z o Push [Z(MENU/GRP)] twice to exit the keyer edit mode. DTMF memory channel select 4 Selected code D DTMF speed The rate at which DTMF memories send individual DTMF characters can be set to accommodate operating needs. e Rotate [DIAL] to set the desired DTMF speed. · Four rates are available: "100 ms" is the fastest; "500 ms" is slowest. to select the default rate. Z r Push [Z(MENU/GRP)] twice to exit the DTMF set mode and return to the normal FM mode display. 68 5 FUNCTIONS FOR RECEIVE Simple band scope This DSP-based simple band scope allows you to display conditions on the selected band, as well as relative strength of signals. The IC-7000 has two modes for the spectrum indication--one is fix mode, and another one is center mode. NOTE: The IC-7000's simple band scope can monitor the displayed frequency during sweeping. Both the receving and sweeping functions use the same receive circuits which must switch at high speed. [. . . ] · 7 m (22 ft) 13-pin, ACC connector to 7-pin + 8-pin ACC connector. OPC-1443 SEPARATION CABLE OPC-1444 SEPARATION CABLE OPC-742 ACC 13-PIN CABLE Required when using both the AT-180 and 2 m linear amplifier. (0PC-1443) (OPC-1444 Provide front panel detached operation for mobile installations or compact transceiver operation. · OPC-1443: 3. 5 m (11. 5 ft) · OPC-1444: 5 m (16. 4 ft) IC-PW1/EURO HF/50 MHz ALL BAND 1 kW LINEAR AMPLIFIER Full-duty 1 kW linear amplifier including an automatic antenna tuner. The amplifier/power supply unit and the remote control unit are separated. An optional OPC-599 is required for connection. 19 150 20 MENU GUIDE Main menu group M-1 SPL A/B FIL XFC M-2 MEM MW MCL V/M M-3 VOX COM AGC TBW (SSB) BRK 1/4 AGC 1/4 AGC VOX AGC (CW) (RTTY) (AM) Sub menu group S-1 VO MET VSC (SSB/AM) (CW) VO KEY MET VSC (RTTY) VO DEC MET VSC VO DTM MET VSC (FM/WFM) S-2 SCN PRI V/M VSC SEL (in memory mode) VOX DUP TON 9600 (FM/WFM) S-3 MW MPW MPR G-1 BAND scope Multi function meter G-2 G-3 BAND scope Multi function meter SWR meter Graphic menu group Push [AF] momentarily Push momentarily Push for 1 sec. Push [Z(MENU/GRP)] to exit Set mode menu 151 MENU GUIDE 20 Set mode description · Set mode menu · Miscellaneous (others) set mode Push [Z(MENU/GRP)] or [AF] switch to return to upper menu · Display set mode · Time set mode Quick set mode No. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ICOM IC-7000




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual ICOM IC-7000 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.