User manual ICOM IC-400PRO

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual ICOM IC-400PRO. We hope that this ICOM IC-400PRO user guide will be useful to you.


ICOM IC-400PRO : Download the complete user guide (1805 Ko)

Manual abstract: user guide ICOM IC-400PRO

Detailed instructions for use are in the User's Guide.

[. . . ] INSTRUCTION MANUAL UHF TRANSCEIVER i400PRO IMPORTANT READ ALL INSTRUCTIONS carefully and completely before using the transceiver. PRECAUTION RWARNING!Safe driving requires your full attention-- anything less may result in an accident. SAVE THIS INSTRUCTION MANUAL -- This instruction manual contains important operating instructions for the IC-400PRO UHF TRANSCEIVER. EXPLICIT DEFINITIONS DEFINITION Personal injury, fire hazard or electric shock RWARNING may occur. WORD NEVER connect the transceiver to a power source of more than 16 V DC. If an incorrect connection is made after cutting, the transceiver might be damaged. [. . . ] Note that CTCSS group mode is not private--anyone can receive your calls. The IC-400PRO is equipped with 51 CTCSS frequency for CTCSS GROUP MODE use. To temporarily hear all signals (including noise) push and hold [MONI]. Do not use CTCSS GROUP MODE if you want to hear signals on all channels. w Push [MONI] for 1 sec. r Push [DUP] to select "OFF" (group mode OFF). 5 Push [DUP] t Push [MONI] for 1 sec. to exit Set mode. · The under bar indicators disappear. D Group code/frequency table Code 01 ----02 03 04 05 06 07 08 09 (unit: Hz) Freq. 21 136. 5 28 173. 8 --- 206. 5 67. 0 10 94. 8 22 141. 3 --- 177. 3 33 210. 7 69. 3 11 97. 4 71. 0 12 100. 0 23 146. 2 29 179. 9 34 218. 1 71. 9 13 103. 5 24 151. 4 --- 183. 5 35 225. 7 74. 4 14 107. 2 25 156. 7 30 186. 2 --- 229. 1 77. 0 15 110. 9 --- 159. 8 --- 189. 9 36 233. 6 79. 7 16 114. 8 26 162. 2 31 192. 8 37 241. 8 82. 5 17 118. 8 --- 165. 5 --- 196. 6 38 250. 3 85. 4 18 123. 0 27 167. 9 --- 199. 5 --- 254. 1 88. 5 19 127. 3 --- 171. 3 32 203. 5 --- OFF 91. 5 20 131. 8 : Stands for the recommended CTCSS frequency. In case a frequency other than at left is used, sometimes the squelch system may not performed correctly. 16 6 SELCALL OPERATION I Calling operation D TX code channel selection The [MONI] (Call) key (in Function mode) enables you to change the TX code channel with [ ]/[ ] keys. 32 TX code channels can be pre-programmed into the IC-400PRO using the optional CS-400PRO CLONING SOFTWARE. To select a TX code channel: q While in Function mode, push [MONI] (Call) for 1 sec. to enter the TX code channel selection mode. · Push [O] (Bank/Func) for 1 sec. to enter the transceiver into Function mode. I General In addition to the group mode operation for silent stand-by, the SelCall operation is available. In Group mode operation, there are 51 ways to make an individual call with CTCSS frequencies versus 100, 000 ways to make an individual call with Selcall using 5tone. SelCall allows you to selectively call another unit that is operating on the same channel. SelCall can also call the entire group on that channel using group call code. The caller station code/name, status message, Answer Back function, automatic scan start function, etc. A variety of functions are available depending on the setting with the CS-400PRO CLONING SOFTWARE. See the help file for setting details. Push [MONI] for 1 sec. The TX code or TX code channel name (if programmed) is displayed. w Push [ ]/[ Push [ ] to select the desired TX code channel. ] or [ ] 17 SELCALL OPERATION 6 e Push [MONI] (Call) to set the TX code channel, and return to Function mode. D TX code number edit The [MONI] (Call) key (in Function mode) enables you to change the TX code contents within the allowable digits. The group call function works by allowing you to edit a special `group code' into the last 2 digits position of the SelCall ID code. To edit a TX code: q While in Function mode, push [MONI] (Call) for 1 sec. to enter the TX code channel selection mode. · Push [O] (Bank/Func) for 1 sec. · Push [ ]/[ ] to select the desired TX code channel, if desired. Push [MONI] 6 r Push [MONI] (Call) to transmit the code on the selected channel. Appears while transmitting Push [MONI] w Push [MONI] (Call) for 1 sec. [. . . ] r OPTIONAL CABLE (OPC-617) Connect an external modem unit, dimmer control, etc. t EXTERNAL SPEAKER JACK Connect a 4­8 (5 W) external speaker, if desired. When using self-tapping screws The universal mounting bracket supplied with your transceiver allows overhead mounting. · Mount the transceiver securely with the 4 supplied screws to a thick surface which can support more than 1. 5 kg. Flat washer 9 Spring washer 38 9 CONNECTION AND MAINTENANCE I Optional UT-108 installation Install the optional UT-108 unit as follows: q Turn the power OFF, then disconnect the DC power cable. r Replace the bottom cover and screws, then re-connect the DC power cable. I Optional UT-109 or UT-110 installation q Turn the power OFF, then disconnect the DC power cable. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ICOM IC-400PRO




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual ICOM IC-400PRO will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.