User manual ICOM AT-130E

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual ICOM AT-130E. We hope that this ICOM AT-130E user guide will be useful to you.


ICOM AT-130E : Download the complete user guide (3388 Ko)

Manual abstract: user guide ICOM AT-130E

Detailed instructions for use are in the User's Guide.

[. . . ] We want to take a couple of moments of your time to thank you for making your IC-V82/U82 your radio of choice, and hope you agree with Icom's philosophy of "technology first. " Many hours of research and development went into the design of your IC-V82/U82. IMPORTANT READ ALL INSTRUCTIONS carefully and completely before using the transceiver. SAVE THIS INSTRUCTION MANUAL-- This instruction manual contains important operating instructions for the IC-V82/U82. EXPLICIT DEFINITIONS DEFINITION Personal injury, fire hazard or electric shock R WARNING!WORD D FEATURES 7 W*-- high transmit output power (*IC-V82, 5 W for AT-130E) CTCSS and DTCS encoder/decoder standard Optional digital modulator/demodulator Optional DTMF decoder Icom, Icom Inc. and the logo are registered trademarks of Icom Incorporated (Japan) in the United States, the United Kingdom, Germany, France, Spain, Russia and/or other countries. i PRECAUTIONS RWARNING!NEVER hold the transceiver so that the antenna is very close to, or touching exposed parts of the body, especially the face or eyes, while transmitting. [. . . ] Each memory channel, 0 to 199, may be assigned to one of the banks for easy memory management. q Push [C·MR] to select memory mode. Push C MR Memory bank setting q Push [C·MR] to select memory mode, then select the deY Z sired memory channel via [Y] or [Z]. Push C MR w Push [A·FUNC] and [8·SET] to enter SET MODE. [VOL] 6 w Push [A·FUNC] and [#·BANK] to enter memory bank selection. · Bank indicator blinks. [VOL] Y Z e Push [Y] or [Z] several times until "bAk" appears. · "­ ­" indication blinks as follows. A FUNC e Rotate [VOL] to select the desired bank, A to J. · Banks that have no programmed contents are skipped. A FUNC r Rotate [VOL] to select the desired bank. ENT SET BANK ENT 8 r Push [·ENT lect the bank. ] (or [D·CLR]) to se- · Indicator stops blinking. Y Z t Push [Y] or [Z] to select the channel in the bank. · No channel numbers are displayed for memory bank operation. t Push [·ENT ] (or [D·CLR]) to assign the channel to the bank and return to regular memory condition. y Repeat steps q to t to assign another memory channel to the same or another bank. 16, 65) in INITIAL SET must be selected "FR, " otherwise the memory bank operation cannot be performed. 25 y To return to regular memory condition, push [A·FUNC] and [#·BANK] to enter memory bank mode, then push [·ENT ] (or [D·CLR]). MODE 6 MEMORY/CALL OPERATION Transferring bank contents Contents of programmed memory banks can be cleared or transferred to another bank. INFORMATION: Even if the memory bank contents are cleared, the memory channel contents still remain programmed. Push [A·FUNC] and [#·BANK], then rotate [VOL] to select the desired memory bank. · Bank indicator blinks. [VOL] w Push [A·FUNC] and [8·SET] to enter SET MODE. [VOL] Y Z e Push [Y] or [Z] several times until "bAk" appears. · Bank indicator appears. A FUNC r Rotate [VOL] to select the desired bank to receive the transferred information or erase the bank contents. · Select "­ ­" indication when erasing the contents from the bank. ENT SET 8 A FUNC Push [·ENT ] (or [D·CLR]) to Y select the bank then push [Y] Z and [Z] to select the desired contents. · Bank indicator stops blinking. t Push [·ENT ] (or [D·CLR]) to transfer or erase, and return to regular memory mode. y Repeat steps q to t for transferring or erasing an another bank's contents. BANK ENT 26 DTMF MEMORY Programming a DTMF code sequence The transceiver has 16 DTMF memory channels (d0 to dF) for storage of often-used DTMF code sequence of up to 24 digits. q Push [A·FUNC], then push [0·OPT] to enter OPTION SET MODE. · Rotate [VOL] to select "dtm. OF, " if necessary. Or when an opY Z tional UT-118 DIGITAL UNIT is installed, push [Y] or [Z] several times until "dtm. OF" appears. 14, 65) Push MONI PWR A FUNC B CALL C MR D CLR 8 A FUNC SCAN 5 TONE 1 P. BEEP 2 T. SCAN 3 BANK e Push [D·CLR] to stop the scan. DUP 4 SCAN 5 SKIP 6 OPT 0 PRIO 7 SET 8 H/M/L 9 ENT · Bank scan --Select the desired bank in step q above. q Push [A·FUNC] and [#·BANK] to select memory bank mode. w Rotate [VOL] to select the desired bank, A to J. e Push [·ENT ] (or [D·CLR]) to select the bank. 31 8 SCAN OPERATION Skip channels In order to speed up the scan rate, you can select memory channels you don't wish to scan as skip channels. q Push [C·MR] to select memory mode, if necessary. · "X" appears. Priority watch Priority watch checks for signals on "priority channels" while operating on a VFO frequency. D Memory or call channel watch While operating on a VFO frequency, memory or call channel watch monitors for signals in the selected memory or call channel every 5 sec. e Push [A·FUNC], then push [7·PRIO] to start watching. w Select a memory channel to set as a skip channel. ePush [A·FUNC] and [6·SKIP] to toggle the skip setting ON and OFF. · "SKIP" appears when the channel is set as a skip channel. Push A FUNC SKIP 6 "SKIP" appears · VFO is displayed, then the decimal point ". ", on the frequency readout blinks. · When the signal is detected on the priority channel, the watching is suspended according to the setting of the scan resume condition. VFO frequency Memory channel 5 sec. 50 msec. r Push [D·CLR] to stop watching. 32 SCAN OPERATION D Memory scan watch While operating on a VFO frequency, memory scan watch monitors for signals in each memory channel in sequence, every 5 sec. q Push [C·MR] to select memory mode, if necessary. · "X" appears. 8 Scan resume condition USING SET MODE wPush [A·FUNC], then push [5·SCAN] to start the memory scan. e Push [A·FUNC], then push [7·PRIO] to start the watching. · VFO is displayed, then the decimal point ". ", on the frequency readout blinks. · When the signal is detected on the priority channel, the watching is suspended according to the setting of the scan resume condition. VFO frequency Mch 3 Mch 2 Mch 1 When a signal is received during scanning, the scan resume condition determines what action the transceiver takes. [. . . ] · BC-146 BATTERY CHARGER + BC-147 AC ADAPTER For regular charging of battery packs. · BC-119N DESKTOP CHARGER + AD-101 CHARGER ADAPTER For rapid charging of battery packs. · BC-121N MULTI-CHARGER + AD-101 CHARGER ADAPTER (6 pcs. ) For rapid charging of up to 6 battery packs (six AD-101's are required) simultaneously. Charging time: 1. 5 to 2 hrs. D OTHER OPTIONS · HM-75A/HM-131L SPEAKER-MICROPHONES Combination speaker-microphones that provide convenient operation while hanging the transceiver from your belt. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ICOM AT-130E




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual ICOM AT-130E will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.