User manual IBP WELL TENS

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual IBP WELL TENS. We hope that this IBP WELL TENS user guide will be useful to you.


IBP WELL TENS : Download the complete user guide (4965 Ko)

You may also download the following manuals related to this product:

   IBP WELL TENS (5685 ko)
   IBP WELL TENS (4948 ko)
   IBP WELL TENS (4899 ko)
   IBP WELL TENS (5166 ko)

Manual abstract: user guide IBP WELL TENS

Detailed instructions for use are in the User's Guide.

[. . . ] 26 Background information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 The Well TENS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 Other points to consider. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 Inserting the battery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] Do not expose the Well TENS to direct sunlight and do not place the Well TENS on a hot surface. 29 6. Unpacking and checking the goods as supplied 1 2 3 4 5 6 7 Storage case Well TENS appliance 4 self-adhesive electrodes on protective film 1 re-sealable bag for storing the self-adhesive electrodes 2 electrical cables 9 V battery Instruction manual 1. Keep the storage case so that you can put the Well TENS away safely in it after each treatment. If any part of the delivered goods is damaged, please contact our Service Department (see Service and Warranty). innovative business promotion gmbh Well TENS Reizstromgerät zur Nervenstimulierung Electrical nerve stimulator Neurostimulateur électrique Elektrostimulator voor het stimuleren van zenuwen Aparato de corriente de excitación para la estimulación de nervios Gebrauchsanweisung Instruction manual Mode d'emploi Gebruiksaanwijzing Manual de instrucciones Modell/Model/Modèle/Model/Modelo: WL-2103A 0434 30 7. Inserting the battery 1 2 3 Faceplate Battery compartment Ribbon pull to aid removal of battery Positive pole Negative pole 1. Open the battery compartment: Using your thumb, push the faceplate down as far as it will go and remove it. Place the battery above the battery compartment with the connections on the right side of the battery compartment. Then press the battery down carefully until it snaps into place. The battery can only be pressed into place if the positive pole is lined up with the pole marked (+) and the negative pole with the pole marked (-). The controls and displays on the Well TENS Item Control On/off knob, pulse strength control Function Use the left knob to switch Channel 1 of the Well TENS on and off. You can increase and decrease the strength of the pulses (0 ­ 80mA) for Channel 1 and Channel 2 independently of one another by rotating the appropriate knob clockwise or anticlockwise. Operating modes C and M: the higher the setting of the pulse rate, the quicker the LED displays flash. By turning this dial you can set the pulse width to any level between 30 s and 260 s. (µs) PULSE WIDTH 1 2 Display 3 4 (Hz) PULSE Rate By turning this dial you can set the pulse rate to any level between 2 Hz and 150 Hz. The setting applies to both channels. Do not attach the self-adhesive electrodes in such a way that the current passes directly through the brain, e. g. 9. 3 Where can you attach the self-adhesive electrodes? The correct positioning of the self-adhesive electrodes is an important factor for successful treatment. As a rule, the self-adhesive electrodes are positioned directly over the painful area or in its immediate vicinity. It is also possible to encircle the painful area with four self-adhesive electrodes. Please refer to the examples of use in section 18 of this instruction manual. 34 9. 4 How to carry out treatment During treatment you should keep a minimum of 1 m away from microwave and short wave appliances. Electromagnetic interaction may affect the functioning of the Well TENS. Use scissors to cut off any lush growth of hair at the points where you want to apply the self-adhesive electrodes as recommended by your doctor or therapist. Use a mild soap solution to clean the skin at the points where you want to apply the self-adhesive electrodes. Rinse off the soap solution well and dab the skin with a towel until it is thoroughly dry. [. . . ] Send the Well TENS to our Service Department ­ see Service and Warranty. Increase the pulse strength. The Well TENS is switched on and the LED displays light up but no stimulation can be felt. The pulse strength is set too low. The cables are not properly connected. The Well TENS is faulty. Check all the cable connections and insert the cables firmly. Send the Well TENS to our Service Department ­ see Service and Warranty. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE IBP WELL TENS




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual IBP WELL TENS will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.