User manual HUMMINBIRD 937C DF COMBO

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual HUMMINBIRD 937C DF COMBO. We hope that this HUMMINBIRD 937C DF COMBO user guide will be useful to you.


HUMMINBIRD 937C DF COMBO : Download the complete user guide (4274 Ko)

You may also download the following manuals related to this product:

   HUMMINBIRD 937C DF COMBO (4250 ko)

Manual abstract: user guide HUMMINBIRD 937C DF COMBO

Detailed instructions for use are in the User's Guide.

[. . . ] 93x_Man_531370-1_A - vs4. qxd 2/18/2005 11:11 AM Page 1 93x_Man_531370-1_A - vs4. qxd 2/18/2005 11:11 AM Page 2 THANK YOU! Thank you for choosing Humminbird®, America's #1 name in fishfinders. Humminbird® has built its reputation by designing and manufacturing top-quality, thoroughly reliable marine equipment. Your Humminbird® is designed for trouble-free use in even the harshest marine environment. In the unlikely event that your Humminbird® does require repairs, we offer an exclusive Service Policy - free of charge during the first year after purchase, and available at a reasonable rate after the oneyear period. [. . . ] The most recent sonar returns are charted on the right side of the window; as new information is received, the older information is moved across the display to the left. A scale with Upper and Lower Depth Range readouts appears along the right edge of the Sonar View. The scale indicates the distance from the surface of the water to a depth range sufficient to show the bottom. Depth Range is automatically selected to keep the bottom visible on the display, although you can adjust it manually as well (see Sonar X-PressTM Menu). Sonar View 1 6 7 8 9 NOTE:If the Depth number is flashing, it means that the unit is having trouble locating the bottom. This usually happens if the water is too deep, the transducer is out of the water, the boat is moving too fast, or for any other reason that the unit can't accurately receive continuous data. Freeze Frame - Pressing any arrow on the 4-WAY Cursor Control key will freeze the screen in the Sonar View and a cursor and cursor dialog box will be displayed on the screen. The cursor can be positioned on the display using the 4-WAY Cursor Control key to determine the depth of any sonar return. In addition, see the effects of menu setting changes with Instant Image Update. Pressing EXIT will exit Freeze Frame and the display will start to scroll. SONAR ZOOM VIEW Sonar Zoom View increases the displayed resolution to separate sonar returns that are very close together, such as those caused by fish suspended close to the bottom or within structure. In Zoom View, the display is split to show a narrow slice of the full range view on the right and the zoomed view on the left. The full range view on the right also contains the Zoom Preview Box that shows what part of the full range view is shown in zoom view on the left; the Zoom Preview Box tracks the bottom in the full range view. As the depth changes, the zoomed view updates automatically to display a magnified image of the bottom. The Zoom Preview Box shows where the zoomed view is in relation to the full range view. The Zoom Level, or magnification, is displayed in the lower left corner and can be changed to suit conditions (see Sonar X-PressTM Menu: Zoom Level). Upper and Lower Zoom Depth Range numbers indicate the depth of the water which is being viewed. 2 5 10 11 3 4 12 1 2 3 4 5 6 Depth Triplog Temperature Speed Cursor Depth of Cursor Depth below Cursor 7 Distance to Cursor 8 Bearing to Cursor 9 RTS® Window 10 Sonar Color Bar 11 Lower Depth Range 12 33 93x_Man_531370-1_A - vs4. qxd 2/18/2005 11:12 AM Page 39 Freeze Frame - Pressing any arrow on the 4-WAY Cursor Control key will freeze the screen in the Sonar Zoom View and a cursor and cursor dialog box will be displayed on the screen. The cursor can be positioned on the display using the 4-WAY Cursor Control key to determine the depth of any sonar return. In addition, see the effects of menu setting changes with Instant Image Update. Pressing EXIT will exit Freeze Frame and the display will start to scroll. SPLIT SONAR VIEW (937c DF Combo and 931c DF models only) Split Sonar View displays sonar returns from the 50 kHz wide beam on the left side of the screen and displays sonar returns from the 200 kHz narrow beam on the right side of the screen. You can use the Split Sonar View to make side by side comparisons between the sonar returns from the 50 kHz wide beam and the 200 kHz narrow beam. Split Sonar View 1 3 Sonar Zoom View 1 6 8 7 2 2 5 7 9 3 10 4 12 1 Depth 2 3 4 5 6 Triplog Temperature Speed Zoomed View Zoom Level 8 6 5 4 11 Upper Depth Range, Full Range View 7 Upper Depth Range, Zoom View 8 Zoom Preview Box 9 Full Range View 10 Lower Depth Range, Full Range View 11 Lower Depth Range, Zoom View 12 1 2 3 4 Depth Triplog Upper Depth Range Lower Depth Range 200 kHz Sonar History Window 5 50 kHz Sonar History Window 6 Temperature 7 Speed 8 34 93x_Man_531370-1_A - vs4. qxd 2/18/2005 11:12 AM Page 40 BIRD'S EYE VIEW (937c DF Combo and 937c Combo models only) 1 Bird's Eye View Bird's Eye View shows a 3D perspective view of the track and the chart land contour from a point above and behind the boat (the eye point). Big Digits on this view provide digital data in a large, easy-to-see format. When you press the 4-WAY Cursor key in the Bird's Eye View, the position of the eye point will shift. This allows you to move and turn the eye point so that you can look off to the sides, or even behind the boat. Pressing the RIGHT or LEFT arrow keys on the 4-WAY Cursor key turns the eye point right or left, while pressing the UP arrow key moves the eye point forward, and pressing the DOWN arrow key moves the eye point backward. [. . . ] This Service Policy is subject to change without notice. 93x_Man_531370-1_A - vs4. qxd 2/18/2005 11:12 AM Page 87 RETURNING YOUR UNIT FOR SERVICE Before sending your unit in for repair, please contact the factory, either by phone or by email, to obtain a Repair Authorization Number for your unit. Please have your product model name and serial number available before calling the factory. If you contact the factory by e-mail, please include your product model name and serial number in the e-mail, and use Request for Repair Authorization Number for your e-mail subject header. You should include your Repair Authorization Number in all subsequent communications about your unit. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HUMMINBIRD 937C DF COMBO




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual HUMMINBIRD 937C DF COMBO will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.