User manual HUBBELL LIGHTING W3

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual HUBBELL LIGHTING W3. We hope that this HUBBELL LIGHTING W3 user guide will be useful to you.


HUBBELL LIGHTING W3 : Download the complete user guide (230 Ko)

Manual abstract: user guide HUBBELL LIGHTING W3

Detailed instructions for use are in the User's Guide.

[. . . ] € When the equipment is not in operation, check that the knobs are in the off position " " . Practical advice Using the burners To obtain maximum efficiency from the burners, it is advisable to use only pans with a diameter that is suitable for the burner being used, so that the flame does not extend beyond the pan base (see following table). When a liquid starts boiling, it is advisable to turn the flame down just enough to keep the liquid simmering. Burner Rapid (C) Semi-Rapid (B) Auxiliary (A) Semi-Fishburner (D) Triple Ring (T) ø Cookware diameter (cm) 22 – 24 16 – 20 10 – 14 16 - 20 24 - 26 • • Replace it in its housing in the position desired. [. . . ] If, despite all of these checks, the cooktop does not function properly and problem persists, call the nearest Merloni Elettrodomestici Customer Service Centre, informing them of: - The type of problem. Never call upon technicians not authorized by the manufacturer, and refuse to accept spare parts that are not original. Safety Is a Good Habit to Get Into • This appliance is designed for non-professional use in the home and its features and technical characteristics must not be modified. These instructions are only valid for the countries the symbols for which appear on the manual and the serial plate. The electrical system of this appliance is safe only when it is correctly connected to an adequate earthing system, as required by current safety standards. The assistance of qualified personnel must be called upon in the following cases: - Installation (in accordance with the manufacturer's instructions); - When in doubt about the operation of the appliance; - Replacement of the electrical outlet becuase it is incompatible with the plug. Contact service centers authorized by the manufacturer in the following cases: When in doubt about the condition of the appliance after having removed the packing; - Damage to or replacement of the power supply cable; - In the case of a breakdown or malfunction: ask for original spare parts. It is recommended that you follow the guidelines below: - Only use the appliance to cook food, avoiding all other uses; - Check the condition of the appliance after it has been unpacked; - Disconnect the appliance from the power supply in the event of malfunction and always before cleaning or maintenance; - When not in use, disconnect the appliance from the power supply and turn off the gas valve (if present); - Always check to make sure that the control knobs are on the “•”/”o” setting when the appliance is not in use; - Cut the power supply cable after disconnecting it from the electrical mains when you decide to no longer use the appliance. € The manufacturer will not be held liable for any damages arising out of: incorrect installation or improper, incorrect or unreasonable use. € • Prevent children and the disabled from coming into contact or having access to the following, as they are possible sources of danger: - The controls and the appliance in general; - The packaging (plastic bags, polystyrene, nails, etc. ); - The appliance, during and immediately after use given the heat generated by its use; - The appliance when no longer in installed (in this case, all potentially dangerous parts must be made safe). (exclusively for cooking appliances) Directly to the Outside Kitchen ventilation The air flow into the room where the appliance is installed must equal the quantity of air that is required for regular 12 The air inflow may also be obtained from an adjoining room, provided the latter is not a bedroom or a room where there is a risk of fire, such as garages, mews, fuel stores, etc. Air from the adjoining room to the one to be ventilated may be made to freely pass through permanent apertures with a cross section at least equal to that indicated above. These apertures may also be obtained by increasing the gap between the door and the floor (fig. If an electric fan is used for extracting the combustion products, the ventilation aperture must be increased in relation to its maximum performance. The electric fan should have a sufficient capacity to guarantee an hourly exchange of air equal to 3-5 times the volume of the kitchen. Prolonged, intensive use of the appliance may require extra ventilation, e. An open window or a more efficient ventilation system by increasing the extraction power of the electric fan if installed. Liquid petroleum gas descends towards the floor as it is heavier than air. Apertures in the outside walls in rooms containing LPG cylinders should therefore be at floor level, in order to allow any gas from leaks to be expelled. Do not store LPG cylinders (even when empty) in basements/ rooms below ground level; it is advisable to keep only the cylinder in use in the room at any one time and connected far from heat sources which could raise its temperature to above 50 °C. Installation These instructions are given for a class 1 and category II 2H3+ appliance. [. . . ] 9 Electrical connection THE APPLIANCE MUST BE EARTHED The hob is designed to work with alternating current at the supply voltage and frequency indicated on the rating plate (situated under the hob or at the end of the instruction booklet). Make sure that the local supply voltage corresponds to the voltage indicated on the rating plate. Connecting the supply cable to the mains electricity supply For models supplied without a plug, fit a standard plug, suitable for the load indicated on the rating plate, onto the cable and connect to a suitable socket. The supply cable must be in such a position that no part of 14 it can reach a temperature of 50 °C above room temperature. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HUBBELL LIGHTING W3




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual HUBBELL LIGHTING W3 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.