User manual HOTPOINT XBC 902 GH DC/HA

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual HOTPOINT XBC 902 GH DC/HA. We hope that this HOTPOINT XBC 902 GH DC/HA user guide will be useful to you.


HOTPOINT XBC 902 GH DC/HA : Download the complete user guide (2798 Ko)

You may also download the following manuals related to this product:

   HOTPOINT XBC 902 GH DC/HA (2536 ko)
   HOTPOINT XBC 902 GH DC/HA (2536 ko)
   HOTPOINT XBC 902 GH DC/HA (2536 ko)

Manual abstract: user guide HOTPOINT XBC 902 GH DC/HA

Detailed instructions for use are in the User's Guide.

[. . . ] 10 Operating Instructions HOB GB IT Italiano, 1 GB English, 11 FR Français, 21 Contents Installation, 12-15 Positioning Electrical connection Gas connection Data plate Burner and nozzle specifications DE Deutsch, 31 NL Nederlands, 41 Description of the appliance, 16 Overall view Start-up and use, 17 Practical advice on using the burners Precautions and tips, 18 XBC 902 GH DC/HA General safety Disposal Maintenance and care, 19 Switching the appliance off Cleaning the appliance Gas tap maintenance Troubleshooting, 20 11 Installation GB !Before operating your new appliance please read this instruction booklet carefully. It contains important information for safe use, installation and care of the appliance. Therefore, rooms containing LPG cylinders must also be equipped with vents to allow gas to escape in the event of a leak. [. . . ] Replacing the nozzles on separate “double flame “ burners: GB Gas connection The appliance should be connected to the main gas supply or to a gas cylinder in compliance with current national regulations. Before carrying out the connection, make sure the cooker is compatible with the gas supply you wish to 13 GB 1. If the appliance is connected to liquid gas, the regulation screw must be fastened as tightly as possible. Once this procedure is finished, replace the old rating sticker with one indicating the new type of gas used. Should the gas pressure used be different (or vary slightly) from the recommended pressure, a suitable pressure regulator must be fitted to the inlet pipe (in order to comply with current national regulations). The internal burner has a nozzle, the external burner has two (of the same size). Replace the nozzle with models suited to the new type of gas (see table 1). Replace all the components by repeating the steps in reverse order • Adjusting the burners’ primary air : Does not require adjusting. Remove the knob and adjust the adjustment screw, which is positioned in or next to the tap pin, until the flame is small but steady. Having adjusted the flame to the required low setting, while the burner is alight, quickly change the position of the knob from minimum to maximum and vice versa several times, checking that the flame does not go out. If the device fails to work when the burners are set to the low flame setting, increase this low flame setting using the adjusting screw. Once the adjustment has been made, replace the seals on the by-passes using sealing wax or a similar substance. The hob can only be installed above built-in ovens with a cooling ventilation system. B D B A C 15 Description of the appliance GB Overall view GAS BURNERS Support Grid for COOKWARE Control Knobs for GAS BURNERS SAFETY DEVICES Ignition for GAS BURNERS • GAS BURNERS differ in size and power. Use the diameter of the cookware to choose the most appropriate burner to cook with. € Control Knobs for GAS BURNERS adjust the power or the size of the flame. • GAS BURNER ignition enables a specific burner to be lit automatically. € SAFETY DEVICE stops the gas flow if the flame is accidentally extinguished. Since the burner is equipped with a safety device, after lighting the burner keep the knob pressed in for about 2-3 seconds to allow the device which keeps the flame lit automatically to heat up. The selected burner can be regulated using the corresponding knob, as follows: 0 Off Maximum Minimum To switch off the burner, turn the knob in a clockwise direction until it stops (when reaches the “0” position). In this case, to activate it, simply start by turning the knob symbol, then press so that it is aligned with the it all the way in and hold it in this position for approximately 6 seconds, until the automatic device keeping the flame alight has heated up. GB Gas burners Each burner can be adjusted to one of the following settings using the corresponding control knob: 0 Off v Maximum Minimum To light one of the burners, hold a lit match or lighter near the burner and, at the same time, press down and turn the corresponding knob anti-clockwise to the maximum setting. [. . . ] Old appliances must be collected separately in order to optimise the recovery and recycling of the materials they contain and reduce the impact on human health and the environment. The crossed out “wheeled bin” symbol on the product reminds you of your obligation, that when you dispose of the appliance it must be separately collected. Consumers may take their old appliance to public waste collection areas, other communal collection areas, or if national legislation allows return it to a retailer when purchasing a similar new product. All major household appliance manufacturers are active in the creation of systems to manage the collection and disposal of old appliances. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HOTPOINT XBC 902 GH DC/HA




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual HOTPOINT XBC 902 GH DC/HA will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.