User manual HOTPOINT-ARISTON GL8TI

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual HOTPOINT-ARISTON GL8TI. We hope that this HOTPOINT-ARISTON GL8TI user guide will be useful to you.


HOTPOINT-ARISTON GL8TI : Download the complete user guide (499 Ko)

You may also download the following manuals related to this product:

   HOTPOINT-ARISTON GL8TI (156 ko)
   HOTPOINT-ARISTON GL8TI (162 ko)
   HOTPOINT-ARISTON GL8TI INSTALLATION MANUAL (152 ko)

Manual abstract: user guide HOTPOINT-ARISTON GL8TI

Detailed instructions for use are in the User's Guide.

[. . . ] National Plumbing codes require a drain pan for any water heater installation. Failure to install one is the sole responsibility of owner and/or installer. Reference UPC 2000 (Uniform Plumbing Code) Section 510 - Protection from Damage or IPC 200 (International Plumbing Code) Section 504- Safety Devices. KEEP THESE INSTRUCTIONS AT HAND SAVE THESE INSTRUCTIONS Technical data MODEL Capacity Voltage Power at 120 Vac Weight Amperage Phases gallons Vac Watts Lbs Amps 1 150 15. 5 GL 2. 5 Ti 2. 75 1500 GL 4 Ti 3. 85 1500 150 17. 3 1 GL 8 Ti 7. 0 1500 150 29. 5 1 110/120 for each model Maximum Water pressure psi 12. 50 for each model WARNING The installer should review the contents of this manual with the owner upon completion of installation, and the manual should be left with the owner and placed in a location close to the installation. 1 FIG. 1/1 Hot water outlet 1/2 NPT male Temperature & pressure relief valve, 3/4 NPT male Cold water inlet 1/2 NPT male 3/4 NPT female tapping for relief valve Temperature & pressure relief valve discharge line to drain COMPONENT PARTS OF GL 2. 5Ti - 4Ti FIG. [. . . ] The discharge opening must not be blocked or reduced in size under any circumstances. National Plumbing codes require a drain pan for any water heater installation. Failure to install one is the sole responsibility of owner and/or installer. Reference UPC 2000 (Uniform Plumbing Code) Section 510- Protection from Damage or IPC 2000 (International Plumbing Code) Section 504- Safety Devices. Periodic discharge of the temperature and pressure relief valve or failure of the element gasket may be due to thermal expansion in a closed water supply system. The water utility supply meter may contain a check valve, backflow preventer or water pressure reducing valve which will create a closed water system. During the heating cycle of the water heater, the water expands causing pressure inside the water heater to increase. The temperature and pressure relief valve may discharge hot water under these conditions which results in a loss of energy and a build-up of lime on the relief valve seat. Install a diaphragm-type expansion tank that is suitable for potable water on the cold water supply line. Install a 125 PSI pressure relief valve in the cold water supply line. Make sure the discharge of this valve is directed to an open drain and protected from freezing. Contact the local water supplier or plumbing inspector for information on how to control this situation. Do not plug the temperature and pressure relief valve. Closed system thermal expansion (for all models) Instructions for use Starting and testing Before connecting the power, fill the tank and system with water and check for leaks. To be certain that all air is out of the water system, open the hot water faucets on your fixtures until constant water flows from them, otherwise damage to the element may occur. B) the red light will come on and remain on until that temperature has been reached, at which point the light will go off, but will automatically come back on when the water temperature drops below the setting chosen. If adjustment is necessary, remove front cover to adjust thermostat (D Fig. 4 -clockwise to increase the temperature and counter clockwise to decrease it). Remove the Phillips screw revealed beneath the round cover plate. Temperature Setting 6 3. The cover (C Fig. When reassembling, work in the opposite way being careful to insert the tongue of the cover into the slot. FIG. 4 B D Maintenance instructions Note: Do not attempt to repair this water heater yourself. Always turn off the power supply to the heater prior to servicing or draining the heater. Periodic maintenance Note: For most of these operations, the water will have to be drained from the heater. For all of these operations the power supply needs to be shut off and the front cover removed. [. . . ] The OWNER and not the Manufacturer or his representative shall be liable for and shall pay for all field charges for labor or other expenses incurred in the removal and/or repair of the product or any expense incurred by the owner in order to repair the product. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO YOU. THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS AND YOU MAY ALSO HAVE OTHER RIGHTS WHICH MAY VARY FROM STATE TO STATE. IMPORTANT: OWNER SHALL KEEP THIS MAKE A CLAIM NOTE: A water heater should be installed in such a manner that if it should leak, the resulting flow of water will not cause damage to the area in which it is installed. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HOTPOINT-ARISTON GL8TI




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual HOTPOINT-ARISTON GL8TI will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.