User manual HONEYWELL ZAPP

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual HONEYWELL ZAPP. We hope that this HONEYWELL ZAPP user guide will be useful to you.


HONEYWELL ZAPP : Download the complete user guide (450 Ko)

Manual abstract: user guide HONEYWELL ZAPP

Detailed instructions for use are in the User's Guide.

[. . . ] It cannot communicate with (but is likewise unaffected by) legacy devices (e. g. the T7270A1001, T7270A1019, T7270B1009, or the RT7070A1008). EN0B-0270GE51, for a complete description of possible layouts and wiring details, including max. ® Depending upon the LONWORKS network configuration used, one or two termination modules may be required (see Fig. Different connections to the termination module are necessary, depending upon whether it is used in a single- or double-terminated network configuration. 5 6 7 8 5 6 7 8 APPLICATION STEPS Overview Steps one through seven describe the engineering. [. . . ] If the teach-in was successful, the W7070A2000 will display the corresponding texts ("PRESENT" and "OK"). symbol indicates that the ZAPP The appearance of the room unit which has been taught-in is an RT7070A2008. 3 EN0B-0286GE51 R1207 ZAPP WIRELESS SYSTEM TEACH teach-in successful RT7070A taught-in PRESENT OK TEACH teach-in successful PRESENT OK T7270B taught-in Fig. T7270B2009 successfully taught-in 3b) Teaching-In a T7270A2001 or T7270A2019 In order to perform the teach-in procedure for a T7270A2001 or T7270A2019, you must first open its housing, revealing the battery compartment and teach-in button. If you then insert the battery or press the teach-in button, the teach message will be sent to the W7070A2000. If the teach-in was successful, the W7070A2000 will display the corresponding texts ("PRESENT" and "OK"). symbol indicates that the ZAPP The appearance of the room unit which has been taught-in is a T7270A2001 or T7270A2019. 4) Completion of the Teach-In Process After successful completion of the teach-in procedure for each individual ZAPP room unit, the W7070A2000 will then recognize commands it receives from them. Further, a symbol for incoming commands together with the room number and the battery status of the room unit will be displayed. incoming commands battery level room number TEACH teach-in successful PRESENT OK T7270A taught-in Fig. Incoming commands / battery status Failed Teach-In In the event that you are unable to teach-in a T7270B2009 Wall Module (i. e. you are unable to read the temperature or setpoint or other functions for a particular room), de-teach the affected room unit and then repeat the teach-in procedure. Fig. T7270A successfully taught-in The appearance also of both the symbol and the symbol indicates that an RT7070A2008 and a T7270A (to both of which the same unique number has been assigned) have been taught-in to the same room. De-Teaching a Taught-In Room Unit It is possible to de-teach (revoke) an individual taught-in room unit. Press the button on the W7070A2000 for 5 seconds to enter the teach-in mode. Select the room you want to de-teach by pressing the button on the W7070A2000 as often as necessary until the unique number of the given room unit appears in the display. Press the button on the W7070A2000 continuously for at least five seconds until the word "PRESENT" in the display disappears De-Teaching All Taught-In Room Units It is possible to de-teach (revoke) all taught-in room units. Switch off the power of the W7070A2000 by unplugging it from the power mains. Press and hold down the button on the W7070A2000 while switching on the power of the W7070A2000 by plugging it back into the power mains. Continue holding down the button on the W7070A2000 until "+de" appears in the display of the W7070A2000 and then immediately release the button (before "-de" or "de" appear ­ otherwise, you will have to start over and repeat the entire procedure). All previously taught-in room units have now been detaught. TEACH teach-in successful PRESENT OK T7270A taught-in RT7070A taught-in Fig. T7270A and RT7070A2008 successfully taught-in Failed Teach-In of T7270A or RT7070A2008 In the event that you are unable to teach-in a T7270A Wall Module or RT7070A2008 Handheld (i. e. you are unable to read the temperature or setpoint for a particular room), deteach the affected room unit and then repeat the teach-in procedure. 3c) Teaching-In a T7270B2009 In order to perform the teach-in procedure for a T7270B2009, on the RT7070A2008, press F and "DOWN" simultaneously for 5 seconds, thus starting the display test and sending the teach message to the W7070A2000 or simply power-up the T7270B2009. Enables manually changing occupancy state to "unoccupied. " Enables manually changing occupancy state to "occupied. " maximum movement time fur sunblind NOTE: The sunblind runtime must be the same in the T7270B2009, the W7070A2000, and in the connected controller (e. g. time for brightening button 5 (bright): Start dimming at 100% or at last light level button 5 (bright): Step height for dimming button 6 (free): max. time for brightening button 6 (free): Start dimming at 100% or at last light level button 6 (free): Step height for dimming Length of timeout after which the W7070A sends nvoSetptOffset and nvoSpaceTemp out onto the network. . unocc ALLOWED . occ nciRmConfig . sblnd_runtime ALLOWED 60 . lamp_runtime . lamp_start . lamp_increment . free_runtime . free_start . free_increment nciSndHrtBt SNVT_time_sec: 1. . 60s 1=100% 0= last level SNVT_lev_percent: 0. . 100% SNVT_time_sec: 1. . 60s 1=100% 0= last level SNVT_lev_percent: 0. . 100% SNVT_time_sec 10 0 100 10 0 100 60 1 2 SH: HB: Sharable (bindable) points can be set up for data sharing either a data source or a destination. [. . . ] 8 = ROOM8 0 = VALID_ID, 1 = INVALID_ID 0 = ENABLED, 1 = DISABLED W7070A2000 neuron application software version nvoStatus . invalid_id . disabled 1 SH: 2 HB: Sharable (bindable) points can be set up for data sharing either a data source or a destination. These points are sent out onto the network at a certain fixed interval (heartbeat). 9 EN0B-0286GE51 R1207 ZAPP WIRELESS SYSTEM ACCESSORIES, AGENCY LISTINGS, ABBREVIATIONS, AND LITERATURE Accessories Wall Holder for Handhelds The RT 70-HRD20-Wall includes 10 wall holders for the RT7070A2008. removable screw-type 3-pole terminal block 3 Honeywell XAL-Term 3 1 shield 0 4 5 shield 6 LON Termination FTT/LPT Bus FTT/LPT Free Park Position 4 plug-in jumper L O N L O N LONWORKS® Termination One or two LONWORKS® terminations are required, depending on the given LonWorks bus layout. Two different LONWORKS® terminations are available: · LONWORKS® termination module, order no. : 209541B · LONWORKS® connection / termination module (can be mounted on DIN rails and in fuse boxes), XAL-Term order no. : Fig. Lonworks® connection and termination module Agency Listings Table 1 provides information on agency listings for wireless ZAPP system products. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HONEYWELL ZAPP




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual HONEYWELL ZAPP will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.