User manual HONEYWELL Z11AS DATASHEET

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual HONEYWELL Z11AS. We hope that this HONEYWELL Z11AS user guide will be useful to you.


HONEYWELL Z11AS DATASHEET: Download the complete user guide (179 Ko)

Manual abstract: user guide HONEYWELL Z11ASDATASHEET

Detailed instructions for use are in the User's Guide.

[. . . ] Z11AS Reverse rinsing actuator for fully automatic filter cleaning Product specification sheet Application The Z11AS automatic reverse rinsing actuator provides fully automatic cleaning for all Honeywell reverse rinsing filters, filter combinations, water supply units and water distributor units. The reverse rinsing intervals are adjustable in sixteen steps between four minutes and three months. [. . . ] When batteries are fitted, the appliance should not be left unplugged for long periods. www. honeywell. com 75 Z11AS Reverse rinsing actuator Method of Operation The Z11AS opens or closes the ball valve according to the set time interval. The opening of the ball valve causes a differential pressure within the filter which activates the reverse rinsing function. The batteries close the ball valve if power fails during reverse rinsing function, thus preventing unwanted water loss. Options For filters and filter combinations HS10, F76, F76C, FK76C, FKN76C, FN76C and FN09 (up to 1996). Z11AS-1/2A = 230 V, 50/60 Hz, 10 W with moulded Schuko electrical plug Z11AS-1/2B = 24 V, 50/60 Hz, 10 W without electrical plug Z11AS-1/2Z = 230 V, 50/60 Hz, 10 W with moulded Type 12 electrical plug for Switzerland From 1997 onwards: Use reverse rinsing actuator Z11AS for filters and filter combinations HS10S, F76S, F76CS, FK76CS, FKN76CS, FN76CS and FN09S. For filters with flanges F76-F and F76S-F Filter size G H L Weight R mm mm approx. kg R 1/2" - R 2" 1/ " 2 150 59 1, 2 (digital) DN 65 - 100 1" 160 81 1, 7 Z11AS-1A = Z11AS-1B = Z11AS-1Z = 230 V, 50/60 Hz, 10 W with moulded Schuko electrical plug 24 V, 50/60 Hz, 10 W without electrical plug 230 V, 50/60 Hz, 10 W with moulded Type 12 electrical plug for Switzerland Remote control (analogous) Additional connection options The Z11AS can be remotely actuated by: a) A volt-free switching circuit b) Via an open-collector output. Reverse rinsing occurs when the inputs "Start" and "U+" have been separated. The reverse rinsing function can be actuated according to demand using the DDS76 differential pressure switch with voltage free switching. Operation occurs when the inputs "Start" and "U+" have been separated, that is, after the differential pressure has fallen below the set value. [. . . ] With a current of 0. 5 V the ball valve is open and with a value between 5 V and 6 V the ball valve is closed. Differential pressure switch Remote monitoring Automation and Control Solutions Honeywell GmbH Hardhofweg D-74821 Mosbach Phone: (49) 6261 810 Fax: (49) 6261 81309 http://europe. hbc. honeywell. com www. honeywell. com Manufactured for and on behalf of the Environmental and Combustion Controls Division of Honeywell Technologies Sàrl, Rolle, Z. A. La Pièce 16, Switzerland by its Authorised Representative Honeywell GmbH EN0H-1120GE23 R1009 Subject to change without notice © 2009 Honeywell GmbH [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HONEYWELL Z11AS




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual HONEYWELL Z11AS will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.