User manual HONEYWELL XL800

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual HONEYWELL XL800. We hope that this HONEYWELL XL800 user guide will be useful to you.


HONEYWELL XL800 : Download the complete user guide (3096 Ko)

Manual abstract: user guide HONEYWELL XL800

Detailed instructions for use are in the User's Guide.

[. . . ] XL 800 Series FOR SMOKE CONTROL HONEYWELL EXCEL 5000 OPEN SYSTEM INSTALLATION AND COMMISSIONING INSTRUCTIONS CONTENTS General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Before Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] No further wiring is necessary. ROOM 1 71 72 LonWorks 73 I/O MODULE 74 XCL8010AU 12 LonWorks 76 I/O MODULE 77 75 78 Multiple Rails in Single Cabinet The multiple rails of a controller system are connected in series. Connect the rail ends as follows: ­ Power supply via power supply terminals 73, 74 or 77, 78 ­ Communication via communication terminals 71, 72 or 75, 76 71 72 73 I/O MODULE 74 71 72 73 I/O MODULE 74 71 72 73 I/O MODULE 74 71 72 73 I/O MODULE 74 75 ROOM 2 73 I/O MODULE 74 LonWorks LonWorks I/O MODULE LonWorks 76 I/O MODULE 77 75 78 I/O MODULE I/O MODULE 76 77 78 75 Fig. Wiring the LONWORKS Bus I/O modules in separate rooms XCL8010AU 12 I/O MODULE 76 77 78 Maximum Cable Length Max. cable length: 1200 meters (4000 ft), supervised. How to Connect Panel Bus and LONWORKS Bus Mixed Controller Systems Connecting I/O Modules For connecting the I/O modules with each other, proceed as described for single-bus controller systems. Connecting I/O Modules to the XCL8010AU Fig. Wiring the power supply and the communication lines to the I/O modules Panel Bus I/O Modules Connect communication terminals 71 74 or 75 78 of LonWorks Bus I/O Modules in Separate Rooms In this scenario, only communication lines must be connected between the rooms. Connect the last module of room 1 to the first module of Panel Bus I/O modules to communication terminals 71 74 or 75 78 of the XCL8010AU Controller Module using either ­ Bridge connectors for flush mounting on a single DIN rail or ­ Cables for separate mounting, e. g. , on multiple rails, separate cabinets, etc. LONWORKS Bus I/O Modules Connect communication terminals 71 74 or 75 78 of room 2: ­ via communication terminals 71, 72 or 75, 76 LONWORKS Bus I/O modules to LONWORKS terminals 11 14 of the XCL8010AU using cables. EN1B-0410GE51 R0908A 12 Excel 800 Description of the XCL8010AU Controller Module Panel Bus modules 71 72 73 74 75 76 77 78 71 72 73 74 Panel Bus modules XCL8010AU 76 77 78 75 71 72 73 74 75 76 77 78 11 12 13 14 1 2 3 4 LonWorks Bus modules 71 72 73 74 75 76 77 78 Fig. Mixed bus system ­ correct wiring Panel Bus modules 71 72 73 74 75 76 77 78 71 72 73 74 LonWorks Bus modules XCL8010AU 76 77 78 75 71 72 73 74 75 76 77 78 11 12 13 14 1 2 3 4 Fig. Mixed bus system ­ incorrect wiring Setting Address of Panel Bus I/O Modules Each Panel Bus I/O module is assigned its own unique address. For the sake of clarity for maintenance personnel, it is recommended that you address the Panel Bus I/O modules in ascending order 0 through F. HEX switch settings and addresses HEX switch address HEX switch address 0 01 8 09 1 02 9 10 2 03 A 11 3 04 B 12 4 05 C 13 5 06 D 14 6 07 E 15 7 08 F 16 Use the rotary HEX switch to set the address to the one already defined during engineering. 13 EN1B-0410GE51 R0908A Mounting/Dismounting Modules Excel 800 LONWORKS Bus Topologies 4 4 LOCK The LONWORKS Bus is a 78-kilobit serial link that uses transformer isolation so that the bus wiring does not have a polarity. it is not important which of the two LONWORKS Bus terminals are connected to each wire of the twisted pair. The LONWORKS Bus does not need to be shielded on the controller module side. The LONWORKS Bus can be wired in daisy chain, star, loop or any combination thereof as long as the maximum wire length requirements are met. HEX switch location NOTE: If the HEX switch setting is changed, the Panel Bus I/O module will revert to its default configuration. With LONWORKS Bus I/O modules, the HEX switch is without function. The recommended configuration is a daisy chain with two bus terminations. LONWORKS Bus lengths, and its simple structure presents the least number of possible problems, particularly when adding on to an existing bus. C-Bus Topologies Via the C-Bus up to 30 C-Bus devices (e. g. , controllers, etc. ) can communicate with one another and a PC central. The CBus must be connected via the individual controllers (open ring). NOTE: Star connection is not allowed because uncontrollable line reflections may occur. Setting the I/O Bus Switch Set the I/O Bus switch S2 of the XCL8010AU Controller Module depending on the modules connected to terminals 71 78 and the desired communication as follows: Table 10. I/O Bus switch settings communication LONWORKS Bus only S2 setting LON terminals 71 74 LONWORKS Bus 75 78 LONWORKS Bus 11 14 LONWORKS Bus Panel Bus and LONWORKS Bus Panel 71 74 Panel Bus 75 78 Panel Bus 11 14 LONWORKS Bus Mounting/Dismounting Modules WARNING Risk of electric shock or equipment damage! Do not touch any live parts in the cabinet. Disconnect the power supply before you start to install the Excel 800 System. More than one disconnect switch may be required to deenergize the system. Do not reconnect the power supply until you have completed the installation. NOTE: The terminal socket of each I/O module can be mounted and wired before inserting and locking the corresponding electronic module. Fig. S2 I/O Bus switch EN1B-0410GE51 R0908A 14 Excel 800 Mounting/Dismounting Modules Mounting/Dismounting Controller/Sockets Mounting Sockets NOTE: When using both Panel Bus and LONWORKS Bus I/O modules in an Excel 800 System, group both Panel Bus modules (light-gray) and LONWORKS Bus I/O modules (dark-gray), e. g. , on different rails. Up to 10 Panel Bus I/O modules can be mounted to one side of the XCL8010AU. [. . . ] Manual overrides (toggle switches) The XFR824AU and XFLR824AU Relay Output Modules are equipped with six manual overrides: one for each relay output. These toggle switches can manually be set to either "auto" or "0" or "1". Relay Output Module status LED behavior mode automatic mode, state "logical ON" automatic mode, state "logical OFF" override mode (setting "0") override mode (setting "1") LED ON OFF flashes flashes N. O. * N. C. * (direct) (reverse) ON OFF OFF ON OFF ON ON OFF *As configured during engineering. 29 EN1B-0410GE51 R0908A Description of the I/O Modules Excel 800 Connection Examples 71 COM A 72 73 74 COM B 24 V~ 24 V~0 COM A COM B 24 V~ 24 V~0 75 76 77 78 72 COM B 73 74 24 V~ 24 V~0 71 COM A NO NC COM CON 11 12 13 14 NO 21 NC 22 COM 23 CON 24 NO NC COM CON 31 32 33 34 NO NC COM CON 41 42 43 44 NO NC COM CON 51 52 53 54 NO NC COM CON 61 62 63 64 25 12 14507287 SERIES POWER MODULE Fig. XF824AU connection example M 71 COM A 72 73 74 COM B 24 V~ 24 V~0 COM A COM B 24 V~ 24 V~0 75 76 77 78 72 COM B 73 74 24 V~ 24 V~0 71 COM A NO NC COM CON 11 12 13 14 NO 21 NC 22 COM 23 CON 24 NO NC COM CON 31 32 33 34 NO NC COM CON 41 42 43 44 NO NC COM CON 51 52 53 54 NO NC COM CON 61 62 63 64 25 3 2 M 1 14507287 SERIES POWER MODULE Fig. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HONEYWELL XL800




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual HONEYWELL XL800 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.