User manual HONEYWELL XL 1000B-C

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual HONEYWELL XL 1000B-C. We hope that this HONEYWELL XL 1000B-C user guide will be useful to you.


HONEYWELL XL 1000B-C : Download the complete user guide (509 Ko)

Manual abstract: user guide HONEYWELL XL 1000B-C

Detailed instructions for use are in the User's Guide.

[. . . ] Excel Web XL1000B/C HONEYWELL EXCEL 5000 OPEN SYSTEM INSTALLATION INSTRUCTIONS TABLE OF CONTENTS Overview of Hardware. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Terminal Blocks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 LonWorks Interface. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Ethernet Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] physical outputs are unaffected. Binary Output (terminals 7+8) LED The LED marked " " indicates the state of the binary output ("watchdog" relay) at terminals 7 and 8 (which is a normally closed contact). Specifically, when it is lit, the alarm contact is open; when it is dark, the alarm contact is closed. For a detailed description of the "watchdog" relay behavior, see Excel Web User Guide (EN2B-0289GE51). In case of a problem, check if the LONWORKS service LED's behavior is changed by resetting the Excel Web controller using the reset button. Please contact Honeywell if this does not solve the problem. Ethernet LEDs The Excel Web controller is equipped with two Ethernet LEDs (see also Fig. 1 on page 2). Binary Output (terminals 9+10) LED The LED marked " " indicates the state of the binary output at terminals 9 and 10 (which is a normally-open contact). Specifically, when it is lit, this means that the application has closed the relay; when it is dark, the relay is open. Ethernet Link LED The LED marked " " indicates the Ethernet link's status. Specifically, it is lit whenever an Ethernet jack has been inserted into the corresponding port and the software has established the Ethernet link. It is dark when the link has been disabled. Ethernet Activity LED The LED marked " " indicates whether or not the Ethernet link is currently active. Specifically, when it flashes, this means that signals are being transmitted / received on the Ethernet network; when it is dark, no messages are being transmitted/received. LEDs L1 and L2 At present, these LED's are not in use. 5 EN1B-0256GE51 R0609 EXCEL WEB CONTROLLER ­ INSTALLATION INSTRUCTIONS Reset Button DIN Rail Mounting/Dismounting 17 mm The reset button can be pressed only using a long, thin tool (e. g. Pressing it reboots the Excel Web controller's operating system and restarts the application. MOUNTING IMPORTANT To allow the evaporation of any condensation resulting from low shipping / storage temperatures, keep the controller at room temperature for at least 24 h before applying power. US requirement, only: This device must be installed in a UL-listed enclosure offering adequate space to maintain the segregation of line voltage field wiring and Class 2 field wiring. In order to meet the criteria for CE certification, the XL1000 controller must be mounted inside an electrical panel. Before Installation slots for DIN rails (center-to-center distance = 100 +3 mm) fastening plate Fig. Housing base (view from below) The Excel Web controller can be mounted onto DIN rails as follows (refer also to Fig. Slide the fastening plate and corresponding screw in the oval hole up against and behind the bottom edge of the lower DIN rail and screw it firmly into place. If necessary, the swivel cover can be locked by inserting a small string lock, lead seal, or screw into either one of the two openings provided. The unit is dismounted by loosening the fastening plate and lifting the unit out of place. Dimensions Allow 30 mm clearance for opening swivel cover. 190 LON CF LON 1 2 3 Allow 30 mm clearance for accessing interfaces. 36. 5 278 4. 4 +/- 0. 3 0. 6 60. 6 step 1 141. 5 +/- 0. 3 100 mm 12 220 +/- 0. 3 5 +/- 0. 3 Fig. Dimensions (in mm) The Excel Web has the following dimensions (W x L x H): 278 x 190 x 61 mm. Its pollution degree (2) makes it suitable for use in residential controls, commercial controls, in a clean environment, or non-safety controls for installation on or in appliances. The Excel Web is suitable for mounting on a standard rail (DIN EN 50022-35 x 7, 5), on walls or in panels, as well as for installation in appropriately-sized wiring cabinets or fuse boxes. 30 mm) to access the interfaces and to open the swivel cover (see Fig. Mounting the Excel Web on to two DIN rails Wall/Panel Mounting/Dismounting The Excel Web controller can be mounted on walls or in panels in any desired orientation. [. . . ] Typically, testing and debugging (using the LIVE CARE functionality of CARE 7) is then performed (in a simulated environment, i. e. The Excel Web is then physically installed in the wall, wiring cabinet, etc. In the course of doing this, the Excel Web controller's terminal blocks are wired and the corresponding RJ45 jacks are inserted into its LONWORKS interface and the Ethernet interface. if the Excel Web controller is to later communicate by modem, too), the corresponding jack can be inserted into the corresponding RS232C interface (namely: Port 3). Option 1: USB (recommended) This USB interface is the recommended interface for downloading applications and firmware via CARE 7. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HONEYWELL XL 1000B-C




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual HONEYWELL XL 1000B-C will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.