User manual HONEYWELL XI581

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual HONEYWELL XI581. We hope that this HONEYWELL XI581 user guide will be useful to you.


HONEYWELL XI581 : Download the complete user guide (967 Ko)

Manual abstract: user guide HONEYWELL XI581

Detailed instructions for use are in the User's Guide.

[. . . ] XI581 / XI582 BUSWIDE OPERATOR INTERFACE USER GUIDE Software License Advisory This document supports software that is proprietary to Honeywell Inc. Before software delivery, the end user must execute a software license agreement that governs software use. Software license agreement provisions include limiting use of the software to equipment furnished, limiting copying, preserving confidentiality, and prohibiting transfer to a third party. Disclosure, use, or reproduction beyond that permitted in the license agreement is prohibited. Copyright © 2009 Honeywell Inc. [. . . ] This document uses the term "point" except where "data point" is used in XI581/XI582 screen displays. This section first describes how to access the 'Data Point Description' function and the options in its menu. It then has subsections that describe: · The display windows that appear when you select a specific point via user address, template search, or type search · Point selection and modification via the 'User Address' option · Point selection and modification via the 'Template Search' option · Point selection and modification via the 'Type Search' option · 'Manual Operation' option (manual-to-automatic, only) · 'Accumulated Runtime' (list only) option · 'Points in Trend' option (disable trend, only) · 'Suppress Alarm' option (unsuppress, only) Procedure At the main menu, use the arrow keys to move to and highlight Data Points. data point Purpose Data Points User Address Manual Operation Accumul. Runtime Type Selection Points in Trend Suppress Alarm Add Template Delete Template Modify Template Template Search 49 EN2B-0126GE51 R0309 ALPHABETIC REFERENCE XI581/XI582 BUSWIDE OPERATOR INTERFACE Note that the 'Add Template', 'Delete Template', and 'Modify Template' items do not display for level-1 operators, and 'Template Search' appears only if there are defined templates. If there are no defined templates, only the 'Add Template' item will be displayed for higher-level operators so they can define templates. User Address This option provides a list of available points that you can select to display point description and modify point attributes. Example: User Address Exhaust_fan Hall_main_lights Main_water_meter Conf_room_temp 1 On 000 23 m3 °C 1 You can select one of these points to view and modify its attributes. See section "Selecting Points by User Address" (page 55) for details. Note that the following options provide specific modification functions that are not available via the User address function. Runtime Points in Trend Suppress Alarm These options provide a list of points related to the option. Runtime', all the points that have accumulated runtime enabled appear on the screen with their accumulated hours. Runtime Points in Trend Suppress Alarm Each option displays a different screen with a specific function. See the relevant sections for details: Change from manual to automatic operation List accumulated runtime Disable a point from trend log (Un)suppress a point's alarm reporting To make other changes (for example, to change from automatic to manual), select the point via the user address, template search, or type search option. The Type Selection option provides a list of point types: EN2B-0126GE51 R0309 50 XI581/XI582 BUSWIDE OPERATOR INTERFACE Analog Input Analog Output Digital Input Digital Output Totalizer Pseudo Totalizer Pseudo Analog Pseudo Digital Global Analog Global Digital Flexible Point All ALPHABETIC REFERENCE You can select a point type to display all the points belonging to that type. Example: Analog Input Cafe_room_temp Conf_room_temp Conf_room_RH Hallway_temp Reception_temp 23 23 10. 0 23 23 °C °C RH °C °C 1 You can select one of these points to view and modify its attributes (the same as for the 'User address' option). See section "Selecting Points by Point Type" (page 57) for details. The 'Add Template', 'Delete Template', and 'Modify Template' items provide functions to create new templates and delete or modify existing templates. The 'Template Search' option provides a list of templates that specify a subset of points. Example of 'Template Search' screen: Template Search: * *RLT* *HSG* *KAE* *NT* 1 You can select one of these templates to view a list of points that conform to template specifications. You can then select a point and view/modify its attributes (the same as for the User address option). See section "Selecting Points by Template" (page 56) for details. See section "Template Operations" (page 72) for a definition of templates and how to add, modify, and delete them. Point Description Windows Description Typically, a Point Description uses some XI581/XI582 display windows to list all attributes for a point. [. . . ] See also section "Logging into a Remote Controller" (page 19) for the procedure to log in to a remote controller. 97 EN2B-0126GE51 R0309 ALPHABETIC REFERENCE XI581/XI582 BUSWIDE OPERATOR INTERFACE Viewing the Remote Trend Buffer Purpose With Excel 500 firmware 2. 03. xx or newer, memory that is not used by the application can be used as additional remote trend buffer for XBS Central A. For a full explanation of this feature of the controller, see Excel 100/500/600 Software Description, EN0B-0092GE51. This section describes how to view the remote trend buffer information. Modifying the values requires that the controller be reset and the steps described in the "Modem and Remote Trend Buffer" section and the "Configuring the Remote Trend Buffer" section be carried out. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HONEYWELL XI581




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual HONEYWELL XI581 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.