User manual HONEYWELL W7763E

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual HONEYWELL W7763E. We hope that this HONEYWELL W7763E user guide will be useful to you.


HONEYWELL W7763E : Download the complete user guide (966 Ko)

Manual abstract: user guide HONEYWELL W7763E

Detailed instructions for use are in the User's Guide.

[. . . ] W7763C, D, E CHILLED CEILING CONTROLLERS LNS PLUG-INS HONEYWELL EXCEL 5000 OPEN SYSTEM USER GUIDE CONTENTS Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Description of Devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Products Covered . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Organization of Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] 18 for connection details for a singly terminated bus. . . . LONWORKS NETWORK IN LONWORKS NETWORK OUT 1 2 Wall module setpoint connection for W7763E only. Termination Module connections for a doublyterminated FTT network. Fig. Termination Module connections for a singlyterminated FTT network. 74-3332-2 20 EXCEL10 CHILLED CEILING CONTROLLER LNS PLUG-INS USER GUIDE Step 5. Order Equipment After compiling a bill of materials through completion of the previous application steps, refer to Table 12 for ordering information. Contact Honeywell for information about Controllers and Wall Modules with no logo. Part Number W7763C1016 W7763C1024 W7763C1032 W7763D1014 W7763D1022 W7763D1030 W7763E1003 T7460 T7560 T7770 C7068A1007 (Europe) Product Description Excel 10 Chilled Ceiling Controllers with setpoint knob, temp. sensor, bypass with setpoint knob, bypass with setpoint knob, bypass with setpoint knob, bypass no setpoint knob, sensor, or bypass Excel 10 Wall Modules Comments °F absolute °C absolute +/- relative °F absolute °C absolute +/- relative See Excel 10 wall module literature for details. Excel 10 Sensors Air Temperature Sensor Echelon-Based Components and Parts FTT LonWorks Router Return air Order from local Echelon supplier (Europe) Order from local Echelon supplier (Europe) Two required per LonWorks segment. Level IV 140°F (60°C) rating Q7751A2002 (US) (UK) (Europe) FTT LonWorks Serial Interface (SLTA) Q7752A2001 (US) (UK) (Europe) Termination Module, part no. 209541B 205979A (US only) SLTA Connector Cable for LonWorks Cabling -- Serial Interface Cable, male DB-9 to female DB-9 or female DB-25. LonWorks (plenum): 22 AWG twisted pair solid Honeywell (US) AK3791 (one twisted pair) conductor, nonshielded. AK3792 (two twisted pairs) Belden 9H2201504 (Europe) LonWorks (non-plenum): 22 AWG twisted pair Honeywell (US) AK3781 (one twisted pair) solid conductor, nonshielded. AK3782 (two twisted pairs) Belden 9D220150 (Europe) Honeywell (US) AK3725 Inputs: 18 AWG (1. 0 mm2) five wire cable bundle. (typical or equivalent) Honeywell (US) AK3702 18 AWG (1. 0 mm2) twisted pair. (typical or equivalent) Honeywell (US) AK3712 16 AWG (1. 5 mm2) twisted pair. (typical or equivalent) Honeywell (US) AK3754 14 AWG (2. 5 mm2) two conductor. (typical or equivalent) Level IV 140°F (60°C) rating Standard thermostat wire NEC Class 2 140°F (60°C) rating Non-plenum Non-plenum Non-plenum 21 74-3332-2 EXCEL10 CHILLED CEILING CONTROLLER LNS PLUG-INS USER GUIDE Step 6. Plug-Ins Configuration Screens General This section will provide details on the configuration options for W7763 Controllers. Using Plug-Ins The configuration process is primarily performed in a series of screens seen as file tabs under the menu option Application Selection and is easily followed using the tables included in this section. There are 8 file tabs: · · · · · · · · Output Input Equipment Control Switching Levels Zone Options Miscellaneous PID Wiring (information only, no configuring). For a complete list of all Excel 10 Chilled Ceiling Controller NV´s, see Appendix C. The specific parameters to be configured in each of these four 74-3332-2 22 EXCEL10 CHILLED CEILING CONTROLLER LNS PLUG-INS USER GUIDE Output The available options for output configurations with the default values shown are listed in Table 13. See Control Provided and Configurations sections above for more information about parameters. [. . . ] It is also used for monitoring purposes, showing the current space temperature used for the control algorithm. nvoSpaceTemp is transmitted immediately when its value has changed significantly (> 0. 5 delta°C). The reported space temperature includes the offset correction nciWallMod. si_space_temp_zero_cal. If a space temperature sensor is not connected or is shorted or if nviSpaceTemp is bound to another node, nvoSpaceTemp is not reported on the network. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HONEYWELL W7763E




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual HONEYWELL W7763E will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.