User manual HONEYWELL W7752G

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual HONEYWELL W7752G. We hope that this HONEYWELL W7752G user guide will be useful to you.


HONEYWELL W7752G : Download the complete user guide (1258 Ko)

You may also download the following manuals related to this product:

   HONEYWELL W7752G DATASHEET (256 ko)
   HONEYWELL W7752G INSTALLATION INSTRUCTIONS (354 ko)

Manual abstract: user guide HONEYWELL W7752G

Detailed instructions for use are in the User's Guide.

[. . . ] W7752D, E, F, G, J AND W7754K, L, M, N, P FAN COIL UNIT CONTROLLERS SYSTEM ENGINEERING CONTENTS Revision overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Description of Devices. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Products Covered . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] OFF time fan overrun time (with fan interlock only) 0 to 600 seconds Notes: 1. Fan run time options apply to all fan speeds. 31 EN0B-0377GE51 R0703 EXCEL 10 FAN COIL UNIT CONTROLLER SYSTEM ENGINEERING Switching Levels See Configurations section above for more information about parameters. FCU Controller switching levels configuration options function cooling stage 1 switching level heating stage 1 switching level cooling stage 2 switching level heating stage 2 switching level cooling stage 3 switching level heating stage 3 switching level cooling hysteresis configuration options 0 to 100% 0 to 100% 0 to 100% 0 to 100% 0 to 100% 0 to 100% 0 to 100%, default 5% 5% 50% 50% 75% 75% 10% heating hysteresis 0 to 100% 10% Notes: 1. Stage switching levels and hysteresis are used for fan control as well as multi-stage heating/cooling outputs control. Zone Options The Zone configuration options are listed in the following table. See Control Provided and Configurations sections above for more information on parameters. FCU Controller zone configuration options function cooling occupied setpoint heating occupied setpoint cooling standby setpoint heating standby setpoint cooling unoccupied setpoint configuration options 50 to 95°F (10 to 35°C) 50 to 95°F (10 to 35°C) 50 to 95°F (10 to 35°C) 50 to 95°F (10 to 35°C) 50 to 95°F (10 to 35°C) default 73. 4°F (23°C) 69. 8°F (21°C) 77°F (25°C) 66. 2°F (19°C) 82. 4°F (28°C) heating unoccupied setpoint 50 to 95°F (10 to 35°C) 60. 8°F (16°C) Notes: 1. Ensure that unoccupied heating<occupied heating<occupied cooling<unoccupied cooling and standby heating<standby cooling. Miscellaneous The options available in the Miscellaneous tab in E-Vision are listed in the following table. See Configurations section above for more information about parameters. FCU Controller miscellaneous configuration options Function Bypass time Override priority Demand limit control bump Cool rec ramp (cooling optimum start gradient) Heat rec ramp (heating optimum start gradient) Configuration options 0 to 1080 minutes last wins - the last command from either the wall module or from the network has priority. 0 to 18 DDF (0 to 10 K) -36 DDF/hour to 0 (-20 K/hour to 0) 0 to 36 DDF/hour (0 to 20 K/hour) 3. 6 DDF (2 K) 0 0 Default 180 minutes last wins EN0B-0377GE51 R0703 32 EXCEL 10 FAN COIL UNIT CONTROLLER SYSTEM ENGINEERING PID The options for configuring PID parameters with defaults are shown in the following table. See Control Provided section above for more information about parameters. FCU Controller PID configuration options function cooling proportional gain 1 configuration options P control: 2. 25 to 180 DDF (1. 25 to 100 K) (0 = disable) PI control: 3. 6 to 180 DDF (2 to 100 K) (0 = disable) 1 default 36 DDF (20 K) 36 DDF (20 K) 250 s 250 s 0 0 1. 8 DDF (1 K) heating proportional gain cooling reset time heating reset time cooling derivative time heating derivative time P control: 2. 25 to 180 DDF (1. 25 to 100 K) (0 = disable) PI control: 3. 6 to 180 DDF (2 to 100 K) (0 = disable) 10 to 3200 seconds (0 = disable) 10 to 3200 seconds (0 = disable) 1 to 3200 seconds (0 = disable) 1 to 3200 seconds (0 = disable) 0. 9 to 18 DDF (0. 5 to 10 K) (0 = disable) cooling boost temperature heating boost temperature 0. 9 to 18 DDF (0. 5 to 10 K) (0 = disable) 1. 8 DDF (1 K) Notes: 1. Prior to version 1. 0. 3, the minimum proportional gain was 7. 2 DDF (4 K) for all control algorithms. Commissioning Commissioning is the process of writing the LONWORKS addresses, the binding information and the configuration to the Excel 10 Controller. E-Vision is the tool used to perform these activities, as described in Appendix B. Job Commissioning The CARE database that is generated for the Excel 10 FCU Controllers and associated Zone Managers contains information concerning interrelationships and network identifications. For this reason, it is mandatory to commission (assign ID and download) all Excel 10 FCU Controllers and the Zone Managers from a single database. ® containing its Neuron ID number. This ID number is on a removable sticker on the side of the W7752 housing or on the adhesive sticker on the top of the W7754 housing and can be typed in manually. Configuring the Zone Manager The Q7750A Excel 10 Zone Manager sends a one-time LONWORKS message containing its 48-bit Neuron ID after any power-up WARMSTART or when the Excel 10 Zone Manager is reset by pressing the reset button. IMPORTANT Pressing the reset button on the Excel 10 Zone Manager causes all application files in the Q7750A, including the C-Bus setup, to be lost. The LONWORKS message is sent only once and only on the LONWORKS network, not on the B-Port. The message will be the same as the one generated after pressing the service button, which is available on Excel 10 FCU Controllers via the Excel 10 wall module's bypass push-button. The Assign ID procedure is the same as for an Excel 10 FCU Controller except, instead of pressing the bypass button, the reset button must be pressed or the power must be cycled (down then up) on the Q7750A Excel 10 Zone Manager. CAUTION If more than one copy of the same database is used in multiple PCs to assign IDs and download to Excel 10 FCU Controllers, there is currently no means to recombine the multiple copies into a single database for any project. [. . . ] It allows the locally-wired window sensor to be used by other nodes on the network. See above. X X X X X This identifies the Excel 10 node type by an eight byte constant describing the node type, major and minor functional release number and bug fix. Functionality of the control algorithm has been revised and affects compatibility with other nodes or the equipment being controlled. The network interface or physical input / output subsystem was revised and affects compatibility with other nodes. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HONEYWELL W7752G




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual HONEYWELL W7752G will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.