User manual HONEYWELL V5833A

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual HONEYWELL V5833A. We hope that this HONEYWELL V5833A user guide will be useful to you.


HONEYWELL V5833A : Download the complete user guide (200 Ko)

You may also download the following manuals related to this product:

   HONEYWELL V5833A (98 ko)
   HONEYWELL V5833A (98 ko)
   HONEYWELL V5833A (98 ko)
   HONEYWELL V5833A (98 ko)
   HONEYWELL V5833A (98 ko)
   HONEYWELL V5833A (98 ko)
   HONEYWELL V5833A (98 ko)
   HONEYWELL V5833A (98 ko)
   HONEYWELL V5833A DATASHEET (187 ko)
   HONEYWELL V5833A INSTALLATION INSTRUCTIONS (98 ko)

Manual abstract: user guide HONEYWELL V5833A

Detailed instructions for use are in the User's Guide.

[. . . ] V5832B/V5833A Small Linear Valves PN16 PRODUCT DATA FEATURES · · · · · · Pressure balanced plug Range of fittings available for different connections Easy to mount, no tools required Flat sealing connections Flat surfaces on body to fit installation tools Standard external threads for Honeywell or field supplied fittings · Adjustment cap for manual operation V5832B GENERAL V5833A SPECIFICATIONS Model Operation Nominal pressure rating Capacity index (kVS) Leakage rate Valve body: Material Size Trim: Stem Plug Suitable medium Controlled water temperature: Rangeability Flow characteristic Stroke Dimensions Two-way: V5832B Three-way: V5833A Stem up to close port A to AB PN16 see tables on page 2 0. 05% of kVS Brass DN25 (1"), DN32 (11/4"), DN40 (11/2") Stainless steel Brass Water, with max. [. . . ] This allows the stem set up for filling or initial heating/cooling during the building construction phase without the use of a controller or actuator. The small electric valve actuators provide automatic control during the opening and closing movement of the valve stem. Three-Way Valves These valves are preferably used as mixing valves, this means: Port AB: Total flow outlet Port A: Controlled flow inlet Port B: Bypass inlet TYPICAL OPERATION All types of valves should be mounted in the return flow. If the p-values exceed 60 kPa, attention should be paid to the development of noise. AB B inlet + - inlet + - A AB B A Two-Way Valves Direction of flow always from port A to port B Port B: Outlet Fig. Two-way valve operation EN0B-0408GE51 R0409 2 V5832B/V5833A SMALL LINEAR VALVES PN16 MOUNTING When installing the valve care must be taken that the flow direction is correct (see section "Typical Operation"). The adjustment cap must be removed from the valve only when the actuator is fitted. The valve should be installed as stress-free as possible with a tightening torque of 25 to 30 Nm. [. . . ] La Pièce 16, Switzerland by its Authorized Representative: Automation and Control Solutions Honeywell GmbH Böblinger Strasse 17 71101 Schönaich, Germany Phone: (49) 7031 63701 Fax: (49) 7031 637493 http://ecc. emea. honeywell. com Subject to change without notice. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HONEYWELL V5833A




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual HONEYWELL V5833A will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.