User manual HONEYWELL V2410

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual HONEYWELL V2410. We hope that this HONEYWELL V2410 user guide will be useful to you.


HONEYWELL V2410 : Download the complete user guide (407 Ko)

You may also download the following manuals related to this product:

   HONEYWELL V2410 INSTALLATION INSTRUCTIONS (551 ko)

Manual abstract: user guide HONEYWELL V2410

Detailed instructions for use are in the User's Guide.

[. . . ] LOCKSHIELD VALVE WITH MEASURING FACILITY PRODUCT DATA V2410 Verafix-MES-II Application 1/2 The Verafix-MES-II is a radiator lockshield valve with measuring support for the supply or return of radiators or heat exchangers. It is used for measuring, shutoff and draining/filling of individual radiators in two-pipe heating systems. [. . . ] Closing or opening of the TRV is immediately indicated on the measuring device as a lower or higher flow rate. The Verafix-MES-II has two fixed kv-values: measuring range II (standard) and measuring range I for low flow rates. For correct measurements the right measuring range or kvvalue has to be fed into the measuring device. NOTE: Measuring and pre-setting at the same time can only be done when a pre-settable TRV body is installed, e. g. Shutoff: The return of the radiator can be shutoff by closing the valve insert. Draining: Draining or filling of the radiator is carried out with the draining adapter (see `Accessories'). Draining of individual radiators using the Verafix-MES-II has no influence on the heating loop or other radiators in the loop. Detailed illustrations of above functions see chapter Shutoff/ Draining and Change to Measuring Range I Please Note: · To avoid stone deposit and corrosion the composition of the medium should conform with VDI-Guideline 2035 · Additives have to be suitable for EPDM sealings · System has to be flushed thoroughly before initial operation with all valves fully open · Any complaints or costs resulting from non-compliance with above rules will not be accepted by Honeywell · Please contact us if you should have any special requirements or needs Dimensions and Ordering Information l Fig. 1) DN 10 15 20 10 15 20 Pipe connection Rp 3/8" Rp 1/2" Rp3/4" Rp 3/8" Rp 1/2" Rp3/4" kvs(cv)-value 0. 2/1. 0(0. 23/1. 17) 0. 2/1. 0(0. 23/1. 17) 0. 2/1. 0(0. 23/1. 17) 0. 2/0. 8 (0. 23/0. 94) 0. 2/0. 9 (0. 23/1. 05) 0. 2/1. 0(0. 23/1. 17) L 52 58 66 75 80 91 Dimensions in mm I H h 26 25 22 29 25 26 34 29 29 49 32 -- 51 32 -- 59 32 -- OS-No. V2410E0010 V2410E0015 V2410E0020 V2410D0010 V2410D0015 V2410D0020 Straight (Fig. [. . . ] 2) DN 10 I II 0. 2 (0. 23) 1. 0 (1. 17) 0. 2 (0. 23) 0. 8 (0. 94) DN 15 I II 0. 2 (0. 23) 1. 0 (1. 17) 0. 2 (0. 23) 0. 9 (1. 05) DN 20 I II 0. 2 (0. 23) 1. 0 (1. 17) 0. 2 (0. 23) 1. 0 (1. 17) Honeywell Subject to change 5 EN0H-2201GE25 R1106 V2410 - VERAFIX-MES-II Automation and Control Solutions Honeywell GmbH Hardhofweg 74821 Mosbach, Germany Phone: +49 (6261) 810 Fax: +49 (6261) 81393 www. honeywell. com EN0H-2201GE25 R1106 November 2006 © 2006 Honeywell International Inc. Subject to change · All rights reserved Manufactured for and on behalf of the Environmental and Combustion Controls Division of Honeywell Technologies Sàrl, Ecublens, Route du Bois 37, Switzerland or by its Authorized Representative. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HONEYWELL V2410




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual HONEYWELL V2410 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.