User manual HONEYWELL T8112D

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual HONEYWELL T8112D. We hope that this HONEYWELL T8112D user guide will be useful to you.


HONEYWELL T8112D : Download the complete user guide (283 Ko)

You may also download the following manuals related to this product:

   HONEYWELL T8112D (309 ko)

Manual abstract: user guide HONEYWELL T8112D

Detailed instructions for use are in the User's Guide.

[. . . ] 9 Installing Batteries . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Troubleshooting Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Limited One-Year Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 2 69-0862--4 Programming Your Thermostat When batteries are installed, your thermostat can be programmed in your hand before it is installed or after it is mounted on the wall. [. . . ] Press Run Program key. Heating Program With the System switch set to Heat, press and release the Set Schedule key once. Use Time keys to program WAKE time and Temp keys to program WAKE temperature for Mon-Fri. Repeat sequence for LEAVE, RETURN, and SLEEP. Set Current Time/Day To set time, press and release Set Clock/Day key once. Press Time keys until current time shows. 6 69-0862--4 Press Set Schedule key until WAKE, SA SU and SET appear on the display. Use Time keys to program WAKE time and Temp keys to program WAKE temperature for Sat-Sun. Repeat the sequence for SLEEP. Cooling Program WIth System switch at Cool, follow the same instructions as for the Heating Program. Press and release Run Program key to start the program. USE TO SET WARMER TEMPERATURE USE TO SET TIME EARLIER LCD DISPLAY RUN PROGRAM KEY AM TU LEAVE Operating Your Thermostat Using Programming Features Temporarily Change temperature for current period only-- Press Temp keys to set desired temperature. The change cancels itself at the next scheduled program change; to cancel sooner, press Run Program key. Fan Auto On System Cool Off Heat HOLD TEMP KEY USE TO SET CURRENT DAY AND TIME USE TO SET PROGRAM PERIOD USE TO SET TIME LATER USE TO SET COOLER TEMPERATURE M8473 7 69-0862--4 Hold a temperature indefinitely--Press Hold Temp key once. If using Temporary Change or Hold features, pressing this key cancels your change. Check Programs--Press Set Schedule key repeatedly to see each time and temperature. Cancel a program--Press Set Schedule key until the program to cancel shows. Pressing the two Time keys together cancels the program. 8 Permanently Change a program--Repeat the steps in the Heating Program or Cooling Program sections, as applicable. Return to the normal program or the starting program--Press Run Program key once. Setting Fan Switch Fan switching positions are: Auto: Normal setting for most homes. A singlespeed fan turns on automatically with the air conditioner or furnace. A two-speed fan usually runs on high with the air conditioner and runs on low with the furnace. Use for improved air circulation during special occasions or for more efficient electronic air cleaning. 69-0862--4 Setting System Switch System switching positions control thermostat operation: Cool: Thermostat controls air conditioning system. Heat: Thermostat controls heating system. Maintaining Your Thermostat Installing Batteries IMPORTANT Batteries must be installed for programming and operation of the thermostat and heating/cooling system. Purchase two AA alkaline batteries; nonalkaline batteries do not last as long and can leak, causing damage to the thermostat or wall surface. Install the fresh batteries, making sure the positive and negative terminals are oriented correctly. 69-0862--4 AM TU LEAVE 2. Fan Auto On System Cool Off Heat 3. 4. SYSTEM SWITCH M5783 FAN SWITCH 9 INSTALL TWO AA ALKALINE BATTERIES AS SHOWN AM TU LEAVE Fan Auto On System Cool Off Heat FAN SWITCH M5781 SYSTEM SWITCH M5782 5. Replace the battery door. As batteries are running low, bATLo indicator flashes for one to two months before batteries run out completely. Replace batteries as soon as possible after indicator starts flashing. 10 After batteries are completely dead, bAtLo indicator disappears, leaving the display completely blank and the heating and/or cooling system not operating. 69-0862--4 To remove batteries, press down on the left ends. If the new batteries are installed within 20 to 30 seconds of removing the old ones, the thermostat does not have to be reprogrammed. If the display is blank, the batteries are dead or incorrectly installed and the thermostat has to be reprogrammed. [. . . ] · Be aware that it is normal for the current setting and display temperature to differ occasionally. · During recovery from setback or setup, setting and display temperature can differ for up to 30 minutes after the recovery period. · The thermostat is factory-calibrated and cannot be adjusted. System On indicator is lit, but no heat is coming from the registers. THIS WARRANTY IS THE ONLY EXPRESS WARRANTY HONEYWELL MAKES ON THIS PRODUCT. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HONEYWELL T8112D




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual HONEYWELL T8112D will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.