User manual HONEYWELL T7460F

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual HONEYWELL T7460F. We hope that this HONEYWELL T7460F user guide will be useful to you.


HONEYWELL T7460F : Download the complete user guide (562 Ko)

You may also download the following manuals related to this product:

   HONEYWELL T7460F DATASHEET (338 ko)

Manual abstract: user guide HONEYWELL T7460F

Detailed instructions for use are in the User's Guide.

[. . . ] Twisted-pair wire is recommended for wire runs longer than 100 ft (30. 5 m). NOTE: Maintain a mounting clearance of approx. (10 cm) to the left-hand side of the module in order to allow a free airflow for the temperature sensor and accessibility of the setpoint dial. Do not mount the wall modules on an outside wall, on a wall containing water pipes, or near air ducts. [. . . ] · All Rights Reserved EN1B-0291GE51 R1105A T7460A, B, C, D, E, F WALL MODULES 7. (T7460B, C, D, E, F only) If the dial does not have the correct position, pull the dial off again and reinsert it with the correct orientation. 5 and make sure that the tab on the underside engages. 4 (100) 1234567 2-3/8 (60) 3-7/16 (86) 2-11/16 (68) 3-7/8 (97) 1-1/16 (27) 4-1/8 (104) Fig. Mounting cover of T7460 wall modules Wiring Attach the wires from the device sensor terminals to the appropriate wall module terminals and set the jumpers according to the connected controller. (mm) NOTE: Not all of the T7460 wall modules are compatible with W7751A, C, E, G (VAV1) and W7752D1 (FCU1) Controllers. IMPORTANT Screw type terminal blocks are designed to accept no more than one 16 AWG (1. 5 mm2) conductor. Insert the wire in the required terminal location and tighten the screw to complete the termination. a) Mount the wall module onto the wall outlet box, or b) bore wall holes as is specified in Fig. Connect the wires to the terminal block according to the specifications in the "Wiring" section. (T7460B, C, D, E, F only) Insert the setpoint dial and turn it clockwise as far as possible. (T7460B, C, D, E, F only) Make sure that the dial's position is such that the 30 (Celsius absolute scale) or the +5 (Celsius relative scale) point to the right-hand side of the wall module (see Fig. 4). Jumper Settings According to the type of controller connected, the following jumpers have to be set on the PCB of the T7460C, D, E, F. NOTE: The "W77xx" at the first jumper position stands for the Excel 10 and Excel 12 controllers: Const. Air Handling Unit W7750A, B (Smart) Variable Air Volume W7751B, D, F, H Fan Coil Unit (FCU2) W7752D, E, F, G Remote Input/Output Device W7761A Hydronic W7762A, B Chilled Ceiling W7763C, D, E Excel 12 W7704xx Fig. Mounting position of setpoint dial EN1B-0291GE51 R1105A 2 T7460A, B, C, D, E, F WALL MODULES Fig. Wiring diagram for T7460C, D, E, F Wall Modules (for the jumper settings, see Fig. [. . . ] Put the limiters approximately opposite the setpoints you want to adjust. In the following example, the setpoints are at about 18 and 27 °C. Order quantity: set of 100 pieces Limiter 1 Limiter 2 12 LonWorks connection terminals Setpoint Limit 1 Fig. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HONEYWELL T7460F




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual HONEYWELL T7460F will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.