User manual HONEYWELL T6580

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual HONEYWELL T6580. We hope that this HONEYWELL T6580 user guide will be useful to you.


HONEYWELL T6580 : Download the complete user guide (480 Ko)

Manual abstract: user guide HONEYWELL T6580

Detailed instructions for use are in the User's Guide.

[. . . ] The fan function consent during the winter operating mode is given with a configurable delay time set in Parameter 24. Analogue and digital outputs FAN: Fan speed control, from one to three speeds. A 230 Vac output, 50 Hz . Max 1. 25 (3 peak)A. WINDOW: The closed contact indicates that the window is open. This causes the valve(s) to close and the fan to stop (energy saving function). The anti-freeze protection function is automatically activated, with 4 °C as default. HEATING VALVE: Choice of a 230 Vac, 0. 8 A command module for maximum four on-off or thermal actuators. SUMMER / WINTER SWITCHING: A closed contact indicates that warm water is flowing through the pipes. [. . . ] 2 : 2-PIPE FAN COIL WITH AN ON-OFF & PWM ACTUATOR The set point is set to the upper point (to the lower point for cooling) of the proportional band, so the valve is closed when the temperature exceeds the set point. The valve opening percentage is regulated by the P+I algorithm. 2nd speed when (set point -90% of the BP) <Tamb < (set point ­30% of the BP). The minimum time at this speed is 2 minutes in normal conditions. 3rd speed when Tamb < (set point ­90%). The minimum time at this speed is 2 minutes in normal conditions. If a variation of more than the BP value occurs between the set point and the actual temperature, the minimum length of time in any one state is reduced to 5 seconds. If the action is cooling, fan control will be opposite to that used during the heating action. During the cooling cycle function, and if the set point is satisfied, the fan will continue to operate at speed 1 for 3 minutes, and will then stop. 4 EN0H8560UK07 R0 RFC BASIC FAN COIL CONTROLLER 4-PIPE FAN COIL WITH ON-OFF & PWM OUTPUT: Fig. 3 4-PIPE FAN COIL WITH ON-OFF & PWM Valve Opens XpH ZEB XpC ORANGE LED BLINKING (1 second ON and 15 seconds OFF) in the OFF state. MODE LED: Function mode display The flashing of the Mode LED shows the current state of the regulator (COMFORT or ECONOMY). When pressing the SEL 3 key, the changes to the flashing of the Mode LED indicates the state of the device. In particular: 0% Temperature C Set o With the controller in COMFORT mode: when pressing the SEL 3 key the Mode LED turns on. With the controller in the ECONOMY mode: when pressing the SEL 3 key the Mode LED flashes regularly 3 times a second. OUTPUT The heating set point is set to the upper point, while the cooling setpoint is set to the heating setpoint plus the dead band. The valve opening percentage is regulated by the P+I algorithm. Dirty Filter Signal and Alarm With the controller in normal operating mode the Mode LED turns on when the filter maintenance hours have been reached. This signal indicates that the filter must be cleaned. SIGNALS AND COMMANDS A A 30 After cleaning the filter, proceed as described below to reset the operating hours count down: 1. The filter operating hours are then reset to zero. 30 20 20 10 Honeywell 10 Daily valve drive SEL0 SEL2 Honeywell SEL2 SEL3 SEL1 SEL0 LED M ODE LED SUMMER/WINTER L E D FIL T E R LED MODE To prevent a possible valve blockage due to a prolonged standstill period, the valve is driven automatically at least once every 24 hours for 150 seconds. 4 Room Unit The room unit has two signal LEDs that give different indications during the various operating and configuration phases. CHANGE OF THE ROOM UNIT FUNCTION MODES FOR ROOM UNITS WITHOUT A DISPLAY CHANGE OF SEASON ­ SUMMER / WINTER (BASIC MODEL ONLY) If Parameter #9 (summer / winter switching) is in the MANUAL mode, changing the season is possible by using the SEL1 KEY on the front panel. Press this key for 5 seconds until the colour of the selected season appears on the S/W LED for 5 seconds. The default value of Parameter #9 is Manual. SUMMER/WINTER LED (BASIC MODEL ONLY): RED ON when the RFC is in the WINTER function mode. RED or GREEN LED BLINKING (1 second ON, 1 second OFF) when the set point is satisfied, but the fan is still running, or when the valve is opening and the fan hasn't been started yet. ORANGE LED BLINKING (1 second ON, 5 seconds OFF) when the room temperature is in the dead band or the set point is satisfied, since the controller is in the COMFORT mode. ORANGE LED BLINKING (1 second ON and 1 second OFF) in the ECONOMY mode, when the set point is satisfied. CHANGE OF FUNCTION MODE (COMFORT / ECONOMY) During normal functioning, while the unit is turned ON, it is possible to change the operating mode mode, from COMFORT to ECONOMY, in succession by using SEL3. Proceed as follows: In the COMFORT mode: when pressing the SEL3 key, the Mode LED turns on and stays on (comfort). By continuing 5 EN0H8560UK07 R0 RFC BASIC FAN COIL CONTROLLER to press the key, the controller switches to the ECONOMY mode after 5 seconds and the Mode LED blinks for 0, 3 seconds ON - 0, 3 seconds OFF until the key is released. From the ECONOMY mode: if the SEL3 key is pressed again, the Mode LED blinks for 0, 3 seconds ON - 0, 3 seconds OFF. [. . . ] These intellectual and property rights may include patent applications, registered designs, unregistered designs, registered trade marks, unregistered trade marks and copyrights. Honeywell reserves the right to modify this document, product and functionality without notice. This document replaces any previously issued instructions and is only applicable to the product(s) described. This product has been designed for applications as described within this document. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HONEYWELL T6580




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual HONEYWELL T6580 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.