User manual HONEYWELL SDC

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual HONEYWELL SDC. We hope that this HONEYWELL SDC user guide will be useful to you.


HONEYWELL SDC : Download the complete user guide (1949 Ko)

You may also download the following manuals related to this product:

   HONEYWELL SDC (3684 ko)
   HONEYWELL SDC MANUAL 2 (533 ko)
   HONEYWELL SDC QUICK GUIDE (528 ko)
   HONEYWELL SDC INSTALLATION INSTRUCTIONS (3684 ko)

Manual abstract: user guide HONEYWELL SDC

Detailed instructions for use are in the User's Guide.

[. . . ] Heating Controller SDC Remote Heating Controller DHC OPERATING INSTRUCTIONS EN2H-0220GE51 R0308 EN2H-0220GE51 R0308 SDC / DHC Contents Contents 1 2 Software version . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Safety instructions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 2. 1 2. 2 Intended use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Requirements for start-up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] HEATING operating mode remains active until another operating mode is activated. Activated continuous lowering operation appears in the basic display with the information RED. HEATING. Display Pos: 18 /156-Honeywell/Bedienung/Standby-Betrieb @ 1\m od_1207644379916_6. doc @ 9420 4. 1. 2. 5. 7 Standby mode In standby mode, the entire system is switched off and protected from frost (all frost-protection functions active). C Hot-water production is disabled and protected from frost. Application Total deactivation of heating and hot water with full building protection. The heat generator and hot-water production remain in operation in case of external demand or demand by other heating circuits on the bus network. The heating circuit pumps are switched on briefly every day (pump anti-blocking protection). The standby mode remains active until another operating mode is activated. Display Activated continuous standby mode appears in the basic display with the information STANDBY. NOTE Pos: 19 /156-Honeywell/Bedienung/Taste_Schaltzeiten_Urlaubsprogramm e @ 1\mod_1207830153957_6. doc @ 10720 4. 1. 2. 6 "Switching time programs / Holiday programs" button Using this button, you can create individualised switching time programs for heating and hot-water operation and set holiday mode. 34. Pos: 20 /156-Honeywell/Bedienung/Urlaubsbetrieb @ 1\m od_1207644072619_6. doc @ 9315 EN2H-0220GE51 R0308 23 Operation SDC / DHC 4. 1. 2. 6. 1 Holiday mode In holiday mode, the heating circuits can be switched off and protected from frost or operated based on the settings for the RED. HEATING operating mode for the duration of the holiday based on the presetting ("Direct circuit" or "Mixed heating circuit 1" / "Mixed heating circuit 2" menu, parameter 25 = holiday operating mode). Setting Press button. The menu-selection level Switching time programs / Holiday programs appears in the display. You can now enter additional holiday timeframes (up to 15 holiday blocks). Application Longer absence while heating operation is active. 24 EN2H-0220GE51 R0308 SDC / DHC Operation Control during holidays At outside temperatures below the frost-protection limit (see 4. 2. 3 "System Parameters" menu, pg. 51) the heating circuits are controlled as follows: Without wall devices: Based on a lowered room temperature specification of 3 C. With wall devices: Based on the room frost-protection limit of the respective heating circuit of 10 C (see "Direct Heating Circuit" or "Mixed Heating Circuit 1", "Mixed heating circuit 2" menu, parameter 08 = room frost-protection limit). Cancellation An active holiday program can be cancelled in case of early return. (current date + 250 days) An active holiday program appears in the basic display with information on the return date. Pos: 21 /156-Honeywell/Bedienung/Taste_Anlageninform ation @ 1\m od_1207644494728_6. doc @ 9450 EN2H-0220GE51 R0308 25 Operation SDC / DHC 4. 1. 2. 7 "System information" button Calls up system information, such as temperatures and counter data. The information on the outside temperature appears first after the button is pressed. Turning the input button causes the system temperatures and the counter and consumption states and operating states of the connected system components to appear. Pressing the input button causes the respective setpoint values to appear. Exceptions Collector flow temperature: Solar tank temperature: Outside temperature: NOTE No setpoint No setpoint Averaged value The displayed information (see the following example) is independent of the installed or enabled system components and control circuits. 26 EN2H-0220GE51 R0308 SDC / DHC Operation Operating overview Press Turn input button to the left button Turn input button to the right Average/current outside temperature value Program/operating mode direct heating circuit/pump status Outside temperature min. (0:00 to 24:00 hours) Program/operating mode mixed heating circuit 1/pump status Heat generator temperature setpoint/actual value Actuator of mixed heating circuit 1/status Hot-water temperature setpoint/actual value Program/operating mode mixed heating circuit 2/pump status Flow temperature setpoint/actual value Actuator of mixed heating circuit 2/status Flow temp of mixed heating circuit 1 setpoint/actual value Program/operating mode hot-water circuit/pump status Flow temp of mixed heating circuit 2 setpoint/actual value Heat generator status Variable input 1 setpoint/actual value Direct heating circuit pump function/status Variable input 2 setpoint/actual value Variable output 1 function/operating state Variable input 2 setpoint/actual value Variable output 2 function/operating state Operating hours Activations of heat generator EN2H-0220GE51 R0308 27 Operation SDC / DHC Setting time for automatic return If the button is pressed and held for approx. With this parameter, the time it takes for automatic return to the basic display can be specified. Setting range OFF No return. The last selected information display continuously remains in the basic display until the next change. [. . . ] Legionella protection is activated on the selected day of the week at the legionella protection time set in the following parameter. The legionella protection function is activated daily at the legionella protection time set in the next parameter. ALL 56 EN2H-0220GE51 R0308 SDC / DHC Operation NOTE If a hot-water thermostat (see 05 parameter = transducer for hotwater circuit) is used to detect the hot-water temperature, these parameters are skipped. Pos: 55 /156-Honeywell/Bedienung/Menues_Direkheizkreis_Mischheizkreis @ 1\m od_1207647253025_6. doc @ 9975 4. 2. 5 "Direct Heating Circuit" / "Mixed Heating Circuit 1" / "Mixed Heating Circuit 2" menu These menus contain all parameters required to program the heating circuit, except the switch time programs. one direct heating circuit and two mixed heating circuits (mixed heating circuit 1 and mixed heating circuit 2) are available as heating circuits. The following described heating circuit parameters are available separately for setting for each heating circuit. Pos: 56 /156-Honeywell/Bedienung/Reduzierter_Betrieb @ 1\mod_1207647295322_6. doc @ 9990 4. 2. 5. 1 Reduced operation During reduced operation, you can select between two operating modes. Factory setting Setting range Set values ECO ECO, RED RED (lowering operation) The heating circuit pump of the direct heating circuit continues functioning during reduced operation (see 4. 2. 3. 2 Time program, pg. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HONEYWELL SDC




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual HONEYWELL SDC will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.