User manual HONEYWELL S6065A1003

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual HONEYWELL S6065A1003. We hope that this HONEYWELL S6065A1003 user guide will be useful to you.


HONEYWELL S6065A1003 : Download the complete user guide (368 Ko)

You may also download the following manuals related to this product:

   HONEYWELL S6065A1003 DATASHEET (121 ko)
   HONEYWELL S6065A1003 DATASHEET (165 ko)

Manual abstract: user guide HONEYWELL S6065A1003

Detailed instructions for use are in the User's Guide.

[. . . ] S6065A1003/2001 LIQUID FLOW SWITCHES SPECIFICATION DATA & MOUNTING INSTRUCTIONS FEATURES · · · Cost-effective flow switches for HVAC applications. [. . . ] They are suitable for monitoring flow in water, oil, cooling circuits, and lubrication systems. Data for other media must be determined empirically. MODELS Specification Flow medium Mounting Maximum pipe temperature Pressure Paddle material Lever Sensor body Housing dimensions Weight Approvals S6065A1003 non-aggressive liquid Rp 1" (ISO7/1) 120 °C 11 bar 1. 4401 yellow brass yellow brass 113 x 70 x 65 mm 850 g TÜV-approved S6065A2001 aggressive liquid Rp 1" (ISO7/1) 120 °C 30 bar 1. 4401 1. 4404 1. 4404 108 x 70 x 72 mm 850 g TÜV-approved ® U. S. · All rights reserved EN0B-0314GE51 R01008 S6065A1003/2001 LIQUID FLOW SWITCHES SWITCH-POINT ADJUSTMENT The flow switch is factory-set to the min. To adjust the device to other levels, turn the adjustment screw clockwise. flow 3 3 (m /h) (m /h) 1" 1" 3. 6 0. 6 / 1. 0 2. 0 / 2. 1 1" 1-1/4" 6. 0 0. 8 / 1. 3 2. 8 / 3. 0 1" 1-1/2" 9. 0 1. 1 / 1. 7 3. 7 / 4. 0 1"+2" 2" 15. 0 2. 2 / 3. 1 5. 7 / 6. 1 1"+2" 2-1/2" 24. 0 2. 7 / 4. 0 6. 5 / 7. 0 1"+2"+3" 3" 36. 0 4. 3 / 6. 2 10. 7 / 11. 4 1"+2"+3" 4" 60. 0 11. 4 / 14. 7 27. 7 / 29. 0 1"+2"+3"+Z* 4" Z 60. 0 6. 1 / 8. 0 17. 3 / 18. 4 1"+2"+3" 5" 94. 0 22. 9 / 28. 4 53. 3 / 55. 6 1"+2"+3"+Z* 5" Z 94. 0 9. 3 / 12. 9 25. 2 / 26. 8 1"+2"+3" 6" 120. 0 35. 9 / 43. 1 81. 7 / 85. 1 1"+2"+3"+Z* 6" Z 120. 0 12. 3 / 16. 8 30. 6 / 32. 7 1"+2"+3 8" 240. 0 72. 6 / 85. 1 165. 7 / 172. 5 1"+2"+3"+Z* 8" Z 240. 0 38. 6 / 46. 5 90. 8 / 94. 2 *For models with the suffix "Z, " the longest paddle must be used to obtain the values indicated in this table. The Z = 8" paddle must be cut to the proper length to fit into the pipe without touching the inside. NOTE: If the flow switch is used as a min. flow controller, another device must be installed downstream for alarm condition activation. DIMENSIONS 70 mm 135 mm 113 mm 65 mm 126 mm paddles (L) pipe Ø rec. Qmax (m3/h) reset / switch point PG11 54 mm R1" 1" 2" 3" 29 mm Fig. [. . . ] La Pièce 16, Switzerland by its Authorized Representative: Automation and Control Solutions Honeywell GmbH Böblinger Strasse 17 71101 Schönaich Germany Phone: (49) 7031 63701 Fax: (49) 7031 637493 http://ecc. emea. honeywell. com Subject to change without notice. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HONEYWELL S6065A1003




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual HONEYWELL S6065A1003 will begin.

 