[. . . ] SPRING RETURN DIRECT-COUPLED DAMPER ACTUATORS 10/20 Nm (88/177 lb-in) FOR MODULATING AND FLOATING CONTROL SPECIFICATIONS Supply voltage S10010 / S20010 24 Vac ±20% / 24 Vdc, 50/60 Hz Nominal voltage S10010 / S20010 24 Vac / 24 Vdc, 50/60 Hz All values stated hereinafter apply to operation under nominal voltage conditions. Power consumption Holding Driving S10010 5 VA / 5 W 14 VA S20010 5 VA / 5 W 16 VA Ambient limits Ambient operating limits -40. . . +60 °C Ambient storage limits -40. . . +70 °C Relative humidity 5. . . 95%, non-condensing Safety Protection standard IP54 Protection class II as per EN 60730-1 Overvoltage category III Lifetime Full strokes 60000 Repositions 1. 5 million Full stroke spring return 60000 Mounting Round damper shaft 10. . . 27 mm Square damper shaft 13. . . 19 mm Shaft length 25 mm End switch (when included) Rating 5 A (resistive) / 3 A (induct. ) Triggering points 7° / 85° Torque rating S10010 10 Nm (88 lb-in) S20010 20 Nm (177 lb-in) Runtime 90 sec (50 Hz) Spring return timing 20 sec (50 Hz) Rotation stroke 95° ± 3° Dimensions see Fig. 8 on page 6 Weight 3. 2 kg Noise rating Driving 40 dB(A) Holding 20 dB(A) (no audible noise) Spring return 50 dB(A) S10010 / S20010 PRODUCT DATA GENERAL These direct-coupled damper actuators provide modulating / floating control for: · air dampers, · VAV units, · air handlers, · ventilation flaps, · louvers, and · reliable control for air damper applications with up to 1. 5 m2 / 16 sq. ft (10 Nm / 88 lb-in) or 4. 6 m2 / 50 sq. ft. [. . . ] Remove the key without rotating it further. end switch scale 0° 7° 10° 15° 75° 80° 83° 90° actuator scale: counterclockwise 92. 5° 90° 83° 80° 75° 15° 10° 7° 0° -2. 5° Fig. Internal end switch triggering points Mechanical Stroke Limit Reduction For applications requiring a span of less than 95°, a simple adjustment can be made. When the rotational mounting of the shaft coupling is changed, the actuator drives less than the full 95° stroke. Once adjusted, the actuator drives until the shaft coupling reaches the mechanical stop (part of the housing). The stop causes the motor to discontinue driving, and the shaft coupling drives no farther. Remove the retainer clip from the shaft coupling and set it aside for later use. Rotate the coupling to the desired fail-safe position, aligning it based on the stroke labeling. fail-safe position of 35° (as indicated on the housing) limits the stroke to 60° (see Fig. 5). Releasing the Manual Positioning To release the manual positioning with no power present, proceed as follows: 1. Turn the key ¼ of a turn in the direction indicated on the cover. NOTE: Once power is restored, the actuator will return to normal automated control. 95° 1 3 4. Replace the retainer clip on the shaft coupling using the groove of the coupling. If necessary, replace the holder and position indicator on the shaft coupling. 2 Fig. Manual positioning 3 EN0B-0463GE51 R0505 SmartAct S10010, S20010 Wiring Connecting to the Power Supply In order to comply with protection class II, the power source of 24 V actuators must be reliably separated from the network power supply circuits as per DIN VDE 0106, part 101. Access Cover ° 90 ° 90 0° 0° 45° DRIVE SPRING RETURN 90° STROKE DRIV E SPR ING RET URN 60° S TRO KE 45° To facilitate wiring the actuator to the controller, the access cover can be detached from the actuator. IMPORTANT Remove power before detaching the access cover. [. . . ] MODULATING CONTROL END SWITCHES NOTE: Internal end switches S1 and S4 must be connected to the same power source. 5 EN0B-0463GE51 R0505 SmartAct S10010, S20010 DIMENSIONS 100 50 50 64 (min. ) 76 (min. Dimensions (in mm) Automation and Control Solutions Honeywell GmbH Böblinger Straße 17 D-71101 Schönaich Phone: (49) 7031 63701 Fax: (49) 7031 637493 http://europe. hbc. honeywell. com Subject to change without notice. Printed in Germany EN0B-0463GE51 R0505 Manufacturing location certified to [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HONEYWELL S10010




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual HONEYWELL S10010 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.