[. . . ] Passive buswide access on C-Bus. DESCRIPTION GENERAL The Q7750A Excel 10 Zone Manager is a programmable master controller for an Excel 10 subsystem. It provides energy management functions and communication interfaces between EXCEL 5000 System products and the Excel 10 Echelon LONWORKS® network. The Q7750A provides C-Bus (9600 baud and 1M baud) and LONWORKS® (78k baud) communication interfaces. [. . . ] Maximum of 120 (one Q7751A Router is required for every segment containing 60 Excel 10 devices). limits / rates / options EN0B-0647GE51 R1109 (74-2950-3) 2 EXCEL 10 Q7750A ZONE MANAGER ­ SPECIFICATION DATA LED Status Information Table 2. (RUN) B-PORT (send) B-PORT (receive) C-Bus (send) C-Bus (receive) LONWORKS® Service LED color green green yellow yellow yellow yellow yellow red LED function if ON Power ON Software running, watchdog triggered Q7750A sends data on RS232 port* Data sent to Q7750A on RS232 port* Q7750A sends data on C-Bus* Q7750A receives data from C-Bus* LONWORKS® network activity* (see NOTE) Blinking not configured LED function if OFF Power OFF Watchdog locked, software not working No communication No communication No data sent on the C-Bus No data received from the C-Bus No LONWORKS® network activity LONWORKS® initialized and working correctly *LEDs 3 through 7 with the frequency of data being transmitted or received (see NOTE). In the case of the C7750A1005, it flickers when data is transmitted or received, but in the case of the C7750A2003, it flickers only while data is being received. Communications Via LONWORKS® The Q7750A uses a transformer-coupled communications port with encoded data presented to controllers and devices on the LONWORKS® at 78K bits per second. The LONWORKS® is insensitive to polarity, eliminating installation errors due to miswiring. With the addition of a Q7751A Router, the maximum allowed number of nodes increases to 120 or 60 per LONWORKS® segment. The recommended wire for the LONWORKS® will level IV, 22 AWG (Belden part number 9D220150) or plenum rated Level IV, 22 AWG (Belden part number (H2201504) non-shielded, twisted pair, solid conductor wire. See also Excel 10 Q7750A Zone Manager ­ Installation Instructions (95-7509). Technical Support for the recommended vendors of Echelon-approved cables. In the case of the C7750A2003: An FTT network can accommodate bus, star, loop or any combination of these topologies. This simplifies system installation and makes it easy to add nodes should the network need to be expanded In the case of the C7750A1005: The TPT LONWORKS® is a daisy chain topology - the bus must go serially from one controller to another without branching. The C7750A2003 can be used to replace the C7750A1005 using a TPT/FTT router. The maximum allowed length of an FTT network is dependent on a number of factors, see Excel 50/500/800 Lonworks Mechanisms ­ Interface Description (EN0B-0270GE51) or Excel 10 Q7750A Zone Manager ­ Installation Instructions (95-7509) for details. Via C-Bus The C-Bus transmits data between EXCEL 5000 System Controllers, Devices and Building Supervisors at 9600 baud or 1 Mbaud (921 600 baud). The maximum allowed C-Bus network length is 1200 m, but with the addition of an XD509 Excel High Speed Repeater, the C-Bus can be extended (an additional 1200 m for each XD509). [. . . ] Environmental Ratings Operating Temperature: 0° to 50 °C Shipping Temperature: -34° to +60 °C Relative Humidity: 5% to 90%, non-condensing. Approval Bodies The Q7750A1xxx is listed under UL 864 (UUKL), File Number S4804. Accessories XI582 Operator terminal with menu-controlled data access XW565 (or 5 m cable for connecting B-Port to the XW582 + XW584) XI582 Operator Interface XW566 XW567 XD505 XD508 14507324-001/U 14507324-002/U XDM506 15 m cable for connecting B-Port to the XI582 Operator Interface 2. 5 m cable for connecting B-Port to a PC 9600 baud C-Bus interface card 921 600 baud C-Bus interface card C-Bus repeater panel mount (without housing) C-Bus repeater panel mount (with housing) Modem submodule Associated Documentation form no. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HONEYWELL Q7750A




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual HONEYWELL Q7750A will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.