User manual HONEYWELL PW50BS INSTALLATION

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual HONEYWELL PW50BS. We hope that this HONEYWELL PW50BS user guide will be useful to you.


HONEYWELL PW50BS INSTALLATION: Download the complete user guide (805 Ko)

Manual abstract: user guide HONEYWELL PW50BSINSTALLATION

Detailed instructions for use are in the User's Guide.

[. . . ] Please take note that any assembly, commissioning, servicing and adjustment work may only be carried out by authorized persons. External transformer; the device is only fed with a protective low voltage of 24 V · Hard or medium-hard drinking water contains large amounts of lime, which can deposit in pipes, fittings and devices and result in irreparable damages. Transformer) Protective extra low voltage Power consumption Protection class Connection size Connection sewerage All works should only be carried out by a qualified person · Ensure that installation is not subject to freezing or extreme heat · A drain connection within five meters distance or two meters height must be available. [. . . ] Set blending o Turn adjuster knob until the desired hardness is reached (recommended: 100 ppm) o Do not turn in too far!Simultaneously press the and buttons for 5 seconds If is displayed, press no further buttons (test mode manufacturer)!8 Manual Regeneration Press the button 5 seconds Manual regeneration starts immediately Flushing takes place via the drain tube during regeneration!2 Display during Operation During normal operation the time and residual capacity are displayed alternately Time Residual volume (litre) 9. 1"Bypass" position In this position the raw water is not softened The raw water runs, via the bypass valve, through the connection adaptor back into the drinking water supply 9. 2"Service" position In this position the raw water is softened and blended with hard water as to the setting of the blending adjuster 9. 3Start-Up operation For the first 1-2 week running period the brand-new water conditioning device is in start-up operation During this period noise development can occur during regeneration but will automatically disappear after approx. Set the time via the and buttons o The clock runs quicker when the and tons are held pressed Time 3Forced regeneration If the programmed number of days between two regenerations has been reached, a forced regeneration is triggered at the set time. Input: OFF up to 99 days Forced regeneration Press the and buttons to change the number of days 2. 3 Manual Regeneration There are two manual regeneration possibilities available 1. Possibility Press the button 5 seconds Manual regeneration starts immediately 1. Possibility Briefly press the key Manual regeneration starts at the set time Operating display flashes 10. Press the button once to go to the next regeneration phase If the water conditioning device is in between two phases (phase display flashes), pressing the button has no effect 1. In order to accept changes for the control valve settings, run the programming until the end. Simultaneously press the and buttons for 5 seconds If is displayed, press no further buttons (test mode manufacturer)!Press the button once to go to the next setting In operation or water consumption the residual capacity is reduced from the set amount to zero. [. . . ] check the inner and outer cabinet for contamination and salt deposits 7. Cabinet made of high-quality plastic material All components subject to pressure in glass-fibre-reinforced plastics All components to brine in Noryl Observe the local requirements regarding correct waste recycling/disposal!Shut-off device in the bypass is not open or Open shut off valve fully only partially open Pipework of the drinking water supply is Clean or replace the pipework calcified or blocked Flow meter is defective Check and, if necessary, replace the flow meter (CS*) Incorrect settings at the control valve Check the control valve settings Water meter is contaminated or defective Clean and, if necessary, replace water meter (CS*) Internal electric cabling is defective Check internal electric cabling (CS*) Call Technical Customer Service Wrong connection of connecting hoses Connect the flexible connection lines correctly Control head is defective Call Technical Customer Service Power supply has been interrupted Check power suppy (mains plug, fuse) Control head is defective Call Technical Customer Service Power failure occurred Set the time Internal pipework is contaminated or leak- Check pipework (CS*) ing Float valve is defective Check float valve (CS*) Device not deaerated Deaerate device Device is in "Bypass" position Set device to "Service" position Incorrect settings at the control valve Check the control valve settings Storage tank is almost or completely empty Check salt level Wrong block salt Use block salt for softeners DIN EN 973 Blending has been set incorrectly Check blending valve and mixing ratio Control valve is contaminated or defective Clean control valve or, if necessary, replace control head (CS*) Check the control valve settings Permanent regeneration Control head is defective Call Technical Customer Service Incorrect settings at the control valve Check the control valve settings No brine intake Incorrect settings at the control valve Check the control valve settings Brine tube is leaking Replace brine tube Drain tube is blocked Clean and, if necessary, replace drain tube Min. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HONEYWELL PW50BS




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual HONEYWELL PW50BS will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.