User manual HONEYWELL NK295S

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual HONEYWELL NK295S. We hope that this HONEYWELL NK295S user guide will be useful to you.


HONEYWELL NK295S : Download the complete user guide (587 Ko)

You may also download the following manuals related to this product:

   HONEYWELL NK295S (949 ko)
   HONEYWELL NK295S INSTALLATION INSTRUCTIONS (949 ko)

Manual abstract: user guide HONEYWELL NK295S

Detailed instructions for use are in the User's Guide.

[. . . ] Refilling combination Compact construction Product specification sheet Application The refilling combination serves automatic filling and refilling from closed heating systems to DIN EN 12828:2003. The refilling combination can be connected in accordance to DIN EN 1717 constantly with the drinking water supply. The refilling combination combines backflow preventer, pressure reducing valve and ball valve in one appliance. [. . . ] If no water is drawn from the downstream system, the backflow preventer is in normal position. The up- and downstream non return valves and the discharge valve are closed. If water is drawn from the downstream system, the backflow preventer is in flow position. The non return valves up- and downstream are opened and the discharge valve is closed. The backflow preventer change to shut-off position (back pressure) if the differential pressure between middle- and inlet chamber is smaller than 10% of the inlet pressure. The upstream non return valve is closed and the discharge valve is opened. The pressure reducing valve reduces the pressure on the inlet side (admission pressure) to the level of the desired pressure on the outlet side (outlet pressure) in individual cases. The pressure reducing valve functions on a force equalisation principle. The force of a diaphragm operates against the spring force of the regulating valve. If the outlet pressure and therefore diaphragm force fall because water is drawn, then the greater force of the spring causes the valve to open. The outlet pressure then increases until the forces between the diaphragm and the spring are equal again. The inlet pressure (admission pressure) has no influence on the regulating valve of the pressure reducing valve. Inlet pressure fluctuation does not influence the outlet pressure, thus providing inlet pressure balancing. Designs NK295S-1/2A = Standard version with threaded connection R1/2" h1 H h2 ø 40mm l3 l2 L l1 l4 Connection size Weight Dimensions R ca. [. . . ] welding beads, sealing materials, metal cuttings and rust. Typical Applications The refilling combination is priority suitable for domestic drinking water supply. The refilling combination can be used for commercial and industrial applications in consideration of its specifications. Below two typical applications: · automatic refilling of the heating system · automatic refilling of systems up to liquid category 3 in accordance with DIN EN 1717 Honeywell GmbH · Subject to change 3 EN0H-1230GE23 R0405 Refilling Combination NK295S Automation & Control Solutions Honeywell GmbH Phone: Hardhofweg Fax: D-74821 Mosbach EN0H-1230GE23 R0405 (49) 6261 810 (49) 6261 81309 www. honeywell. com 4 Honeywell GmbH · Subject to change [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HONEYWELL NK295S




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual HONEYWELL NK295S will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.