User manual HONEYWELL NA 228 S-A

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual HONEYWELL NA 228 S-A. We hope that this HONEYWELL NA 228 S-A user guide will be useful to you.


HONEYWELL NA 228 S-A : Download the complete user guide (233 Ko)

You may also download the following manuals related to this product:

   HONEYWELL NA 228 S-A (824 ko)
   HONEYWELL NA 228 S-A INSTALLATION INSTRUCTIONS (824 ko)

Manual abstract: user guide HONEYWELL NA 228 S-A

Detailed instructions for use are in the User's Guide.

[. . . ] NA 228 S-A Automatic Refilling Unit for closed heating or cooling systems Product specification sheet Application The NA 228 S-A automatic refilling unit with DVGW-tested backflow preventer permits the fixed connection of closed heating or cooling systems to the drinking water supply network. [. . . ] Special Features q Components DVGW approved q q q q q Construction The automatic refilling unit comprises: q q q q q q q q q q q q q Powder coated pressed steel housing Drinking water and system connection with shutoff ball valve Pressure switch for cut-in and cut-out pressures Electronic time relay Fault indicator lamp and cut-out button Pressure gauges for inlet and system pressures Discharge tundish Electrical plug for remote connection ON/OFF switch One metre connection cable without plug Water meter Bush for cable connection to a building management system Operating-time meter q q q q q q Electrical changeover valve for control of the backflow preventer Supplementary hot-water-resistant check valve for increased protection of the drinking water network Setting facility for fast filling or refilling of the system Pressure switch with separately adjustable cut-in and cut-out pressures Time relay, for limitation of the refilling period Standardised discharge connection Remote volt-free connection Bush for cable connection to a building management system Circuit protection for volt-free connection Operating-time meter, measures the refilling time Water meter, measures the refills 4 GRÄSSLIN 2 0 bar 6 8 h UWZ 52 220V~50Hz vom Kal twa sse rne tz 5 SPX 1996 10 15 0 bar 16 8 NA 22 at Typ: lautom DVGW Hz /60 Nachfül TÜV / ~ 50 230V 30 Watt Range of Application The following operating data applies for the downstream system: System pressure: Maximum 6. 0 bar Temperature: Maximum 120 ºC Technical Data Refilling: Fast filling: Duration of fill: Cut-in pressure: Cut-out pressure: Pressure switching differential: Water inlet pressure: Remote connection: Supply voltage: Power consumption: Connection size: Flow rate 110 litres/h at p = 2. 0 bar Flow rate finely adjustable between 110 litres/h and 1100 litres/h at p = 2. 0 bar Adjustable between 5 and 100 minutes Adjustable between 0. 2 and 7. 5 bar Adjustable between 0. 5 and 8. 0 bar 0. 3 to 0. 5 bar (depending on pressure range) Minimum 3. 0 bar, maximum 6. 0 bar** Volt-free contact 230V, 50/60 Hz 30W R1/2" and Ø15 221 * For temperatures above 100ºC, the pressure at the highest point in the system when the system is cold must be at least 1. 0 bar above the operating pressure (static height plus 1. 0 bar). **A pressure reducing valve must be fitted before the refilling unit for pressures above 6. 0 bar Subject to change 03/99 Automatic Refilling unit NA 228-SA Method of Operation If the system pressure falls to below the lower set value, for example through leakage losses, then the changeover valve is opened by electrical impulse via the pressure switch and thereby permits supply to the backflow preventer. The inlet pressure moves the backflow preventer to the flow position and the system is refilled until the pressure rises to the upper set limit. The time period of the refill is monitored by the time relay and the operating time counter. Once the upper limit value has been reached, the pressure switch closes the changeover valve and the backflow preventer goes to the shutoff position (open to atmosphere). If the inlet pressure falls to the operating pressure of the backflow preventer (2 bar) during the automatic refilling operation, then the backflow preventer automatically goes to the shutoff position (open to atmosphere). The shutoff position of the backflow preventer is indicated in the viewing window (green visible = shutoff position) Option NA 228 S-A T NETZ EIN/AUS B Fremdanschluß - potentialfrei - zur Heizungsanlage 00000000 5 0 bar 10 16 15 Connection size R Soldered connection size (mm) Weight (approx. kg) Dimensions (mm) H B T Test Certificate Number /2" Ø15 16 380 370 160 101/87/147 1 222 Braukmann Water Control . [. . . ] Box 1347 D - 74819 Mosbach-Germany Phone: (49) 62 61/ 0 62 61/8 10 · Fax: 0 62 61/8 13 09 224 http://europe. hbc. honeywell. com [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HONEYWELL NA 228 S-A




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual HONEYWELL NA 228 S-A will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.