User manual HONEYWELL MP953D

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual HONEYWELL MP953D. We hope that this HONEYWELL MP953D user guide will be useful to you.


HONEYWELL MP953D : Download the complete user guide (850 Ko)

You may also download the following manuals related to this product:

   HONEYWELL MP953D (1524 ko)

Manual abstract: user guide HONEYWELL MP953D

Detailed instructions for use are in the User's Guide.

[. . . ] Dimensions Model MP953A, 125 (5") MP953C, 125 (5") MP953A, 200 (8") MP953C, 200 (8") MP953A, 330 (13") MP953C, 330 (13") MP953B, 180 (7") MP953D, 180 (7") EØ 130 210 343 180 F 192 -237 -327 -242 -G -120 -165 -255 -137 H 120 140 200 120 107 --K Table 2. MP953A5005 MP953A5039 MP953A5054 MP953B5003 MP953C5001 MP953C5019 MP953C5027 MP953C5068 MP953C5076 MP953C5084 MP953C5142 MP953C5159 MP953D5009 MP953D5025 pressure range (kPa) 34. 5 or 69 13. 8 to 48. 3 55. 2 to 82. 8 27. 6 to 75. 9 13. 8 to 48. 3 55. 2 to 82. 8 27. 6 to 75. 9 13. 8 to 48. 3 27. 6 to 75. 9 55. 2 to 82. 8 27. 6 to 75. 9 adjustable start point 20. 7 to 69 positioner yes diaphragm Ø 125 mm (5") 200 mm (8") 330 mm (13") 180 mm (7") 125 mm (5") 20 -no 200 mm (8") 330 mm (13") 180 mm (7") 38 20 retracts extends 120 °C stroke 20 38 retracts stem action extends max. · All rights reserved EN0B-0552GE51 R1009 MP953A, B, C, D PNEUMATIC ACTUATORS FEATURES · · · · · Rolling diaphragm for long life and low hysteresis Easily attached to valve assembly May be installed after valve piping Slide lock feature permits simple engagement to valve stem Models with positive-positioning relay available control air valve stem ACCESSORIES Extension Yokes The extension yoke (see also Fig. [. . . ] Screw the stem button on the (single or double) stem extension until it bottoms. Screw the stem extension on the stem until it bottoms (flats or locking-pin hole provided). Rotate the stem extension as required to adjust dimension "Y" as per Table 5 to the value listed, then lock the stem extension in place by tightening the hex nut. TYPICAL OPERATION In a direct-acting (normally-open valve) system, an increase in control air pressure will force the actuator diaphragm and cup downward, forcing the valve stem down to proportionally close off the flow through the valve. Operators without the positive positioner have branch line pressure applied to the diaphragm. Operators with positive positioners have up to full main air pressure applied to the diaphragm to ensure that the valve is positioned proportionally to the branch line pressure. EN0B-0552GE51 R1009 2 MP953A, B, C, D PNEUMATIC ACTUATORS stem-locking slide stem button Fig. Dimensions Y, in mm actuator size action 5", 7" 8" 13" to open valve size DN DN DN valve series 15. . . 80 Y1 15. . . 80 Y2 100. . . 150 Y3 V5016A V5025A 89 133 190 V5328A V5011R, S 89 133 - V5013R, E 107 151 -V5015A -- 227 V5050A 107 151 V5329A, C -valve size DN DN DN action valve series 15. . . 65 15. . . 65 80. . . 100 to open V5049A 89 133 190 4. Turn the stem connector screw by its screw-slot counterclockwise to back out the stem button until the actuator is in contact with the shoulder of the stem button. Push the actuator onto the valve bonnet and hold it firmly in place; tighten the two set screws 6. Load the stem by turning the stem connector screw clockwise by its screw slot. a) On a straight-through valve (position 1), turn the stem connector screw until a clearance A of approx. 1. 5 mm each is required at both ends of the stroke to permit proper close-off. If clearances A and B cannot be adjusted following the procedure outlined above, check the stem height "y" and adjust, if necessary. Y1 without stem extension for MP953A, C 5" MP953B, D7" Y2 with stem extension for MP953A, C 8" Fig. Place the actuator on the valve without pushing the stem down. ADJUSTMENTS NOTE: Adjustments are necessary only for the GRADUTROL-Relay used with the MP953A, B. The graduations of the external calibration scale on the knob present various values within the different ranges. After completing the adjustment procedure, do not change the position of GRADUTROL-Relay (with respect to the actuator). stem button connector clearance "B" (measured when spring is compressed) clearance "A" set screw Fig. Attaching the stem connector screw 3 EN0B-0552GE51 R1009 Y3 with stem extension for MP953A, C 13" MP953A, B, C, D PNEUMATIC ACTUATORS set screw operating range 70 kPa (10 psi) range adjustment ALL screws "1" and "2" tightened. [. . . ] 7), and adjust dimension "y" to the value listed in Table 6. Lock stem extension into place by tightening the hex nut, and attach the yoke. Mounting actuators with extension yoke actuator MP953A, C, 5" MP953B, D MP953A, C, 8" "y" (mm) 89 107 133 151 valve V5011R, S, V5328A, V5016A, V5025A, V5049A V5013R, E, V5329A, C, V5050A V5011R, S, V5328A, V5016A, V5025A, V5049A V5013R, E, V5329A, C, V5050A 70 mm Fig. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HONEYWELL MP953D




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual HONEYWELL MP953D will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.