User manual HONEYWELL MICRONIK 200

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual HONEYWELL MICRONIK 200. We hope that this HONEYWELL MICRONIK 200 user guide will be useful to you.


HONEYWELL MICRONIK 200 : Download the complete user guide (449 Ko)

You may also download the following manuals related to this product:

   HONEYWELL MICRONIK 200 INSTALLATION INSTRUCTIONS (625 ko)

Manual abstract: user guide HONEYWELL MICRONIK 200

Detailed instructions for use are in the User's Guide.

[. . . ] HONEYWELL Operator's Terminal MicroniK 200 USER GUIDE EN2B-0212GE51 R0102 OPERATOR'S TERMINAL EN2B-0212GE51 R0102 CONTENTS OPERATOR'S TERMINAL CONTENTS Software installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Hardware installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Screen Layout and Functions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 The Main Menu. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] In addition, a "Note" containing a more detailed description can be defined (define the "Note" before storing!). Copy of Control and Configuration Parameters from a Data File Menu [M200], see Chap. The data stored in a file can be loaded into the controllers as follows: · Copy all parameters (including schedule) into an individual controller. · Copy schedule to all controllers 5 EN2B-0212GE51 R0102 OPERATOR'S TERMINAL SCREEN LAYOUT AND FUNCTIONS Main Temperature Monitoring within Programmed High and Low Limit Values Menu [Monitoring] see Chap. The temperature T1 of every controller can be monitored for minimum and maximum values. The maximum deviations in each case are recorded in a list. Printing of Main Menu The parameter values and the display are printed out on the Windows standard printer by a mouse click on [Print]. Update of Programmed Control and Configuration Parameters [Read M200 parameter] The parameter values are read and displayed automatically with selection of a controller. However, if the parameter values of a selected controller vary directly on the controller, the controller parameters need to be read again. Alternatively, reselect the controller from the table "M200 connected". Program Exit Close the main program with the Windows button [X]. All menus, which are still open, will be closed and the program terminated. Production Date Code The Production date (Date Code) of the controller is displayed at lower-left corner in the main menu. EN2B-0212GE51 R0102 6 MENU OVERVIEW OPERATOR'S TERMINAL MENU OVERVIEW [Load Default] The factory set default parameter settings are loaded into the M200 controller. As a result, all changed parameters are overwritten. [Read M200-Parameter] The parameter values are read automatically and displayed with selection of a controller. However, if the parameter values of a selected controller vary directly on the controller, the controller parameters need to be read again. Alternatively, reselect the controller from the table "M200 connected". [Options] [Port ] [German/English] [Last Bus address] Input of COM port number (1-4), at which the Excel adapter is connected. The individual Bus address of the controllers should be adjusted in ascending order starting with 1. . . . Set last bus address to the number of controllers present on the bus (highest controller address). Leave menu. [Exit] 7 EN2B-0212GE51 R0102 OPERATOR'S TERMINAL MENU OVERVIEW [M200] Saving and Copying the Control and Configuration Parameters Saving M200 Parameters in a Data File The settings of a controller can be stored in the PC. All settings (including schedule) are stored every time into an individual file. In addition, a Note with a more detailed description can be assigned (assign the Note before storing!). Procedure: · Select controller in the table "M200" with a mouse click. The extension ". M20" is appended automatically and need not be entered. An already-existent file name can be overwritten by clicking on the corresponding file in the list "file". · In the field "Note", insert comments about this file. · With a mouse click on [---->], all controller data are stored in the file. These are stored under . . M200\Data\xxx. M20 and have the extension . M20. [. . . ] Transfer the time and date from the PC to the controller by means of a mouse click on the command button (4). Setting the Summer / Winter Daylight Saving Time Period In the field "Summer, <--> winter time" (6) the months can be modified. For this, click onto the round command button (5) and select the respective month from the calendar. Menu Exit Mouse click onto command button (1) at upper left. [Monitoring] 17 EN2B-0212GE51 R0102 OPERATOR'S TERMINAL MENU OVERVIEW Monitoring the temperature T1 (or, in the case of controller type R7426D2000, input U1) · Reporting, if the temperature T1 exceeds the high and/or low limits: 1. Message and report are displayed whenever the temperature T1 is above the units. Offset values for the respective mode (Night and Standby) is added or subtracted to the high and low limits. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HONEYWELL MICRONIK 200




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual HONEYWELL MICRONIK 200 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.