User manual HONEYWELL KALTECSOFT KS10S

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual HONEYWELL KALTECSOFT KS10S. We hope that this HONEYWELL KALTECSOFT KS10S user guide will be useful to you.


HONEYWELL KALTECSOFT KS10S : Download the complete user guide (1673 Ko)

You may also download the following manuals related to this product:

   HONEYWELL KALTECSOFT KS10S (2311 ko)

Manual abstract: user guide HONEYWELL KALTECSOFT KS10S

Detailed instructions for use are in the User's Guide.

[. . . ] Please take note that any assembly, commissioning, servicing and adjustment work may only be carried out by authorized persons. Faults made during installation, maintenance or operation make all claims for warranty void. Please note as owner and operator of the plant the notification and information obligations that result from sections 13, 16, and 21 of the drinking water ordinance:2001. Disinfection The softening device is equipped with a disinfection unit that disinfects all drinking water porting part of the softening device during each regeneration. [. . . ] * according to the water distribution company All works should only be carried out by a qualified person · Ensure that installation is not subject to freezing or extreme heat o Avoid direct exposure to sunlight. If the input pressure is more than 5 bar, then a pressure reducer needs to be installed ahead of the softening device according to DIN 1988. ⷠIt should be checked whether a dosing device to prevent corrosion should be added to the plant. F762) should be installed no more than 1 metre ahead in flow direction of the softening device to protect the plant. ⷠThe following is needed for operation in the close vicinity of the device: o a channel interface (at least DN50) o separate mains connection (230 V / 50 Hz) o Floor drain 8. To avoid irreplaceable damages on the softening device, all welding and soldering work in the near vicinity should be completed before the mounting. Put diluting device into bypass position o close the two outer valves o open the middle valve 2. Put diluting device into operating position o Slowly open the input valve completely o Slowly open the output valve completely o Close middle valve 4. Pour salt tablets into the salt supply container Use only salt tablets acc. Connect transformer to the device o Remove cover to the salt container and hood o Plug the cable shoes of the transformer into the controller 8. Replace hood and cover, guide the cable out of the back of the device 9. Starting regeneration o Press the Regeneration key for 5 seconds o Display Regeneration active flashes o The time is displayed in the display during the regeneration process After the end of the regeneration (duration 45 minutes) o Display Regeneration active goes out. There is a connection to the power supply o Display Current time flashes Set the raw water hardness by pressing + or The hardness of the raw water can be inquired from the water distribution company. Setting the mix water hardness by turning the screw at the base of the diluting device o Use screwdriver o Turn counter-clockwise = increase water hardness on output side o Turn clockwise = decrease water hardness on output side 2. check the mix water hardness at a tapping point o Open tapping point completely to ensure sufficient flow 3. Readjust by turning the screw if necessary Press the REGENERATION key for 5 seconds o Display Regeneration active flashes o Continue with point 2 to 11 chapter 10. 2 The settings, excluding the time remain intact, but need to be confirmed with MENU / OK . The regeneration needs to be carried out to return to the normal operating mode. [. . . ] 1 Power Failure: Brief power failure: All settings including the time remain intact After longer power outage: o Display Current time flashes Problem No water supply to the device Cause Shut-off device in the bypass is not open or only partially open Remedy Open shut off valve fully Pipework of the drinking water supply Clean or replace the pipework is calcified or blocked Device does not regenerate Flow meter is defective Internal electric cabling is defective Check and, if necessary, replace the flow meter (CS*) Check internal electric cabling (CS*) Wrong connection of connecting hoses Connect the flexible connection lines correctly Rotary disc valve defective Nothing is displayed Incorrect time is displayed Insufficient function Power supply has been interrupted Rotary disc valve defective Power failure occurred Device not deaerated Call Technical Customer Service Check power suppy (mains plug, fuse) Call Technical Customer Service Set the time Deaerate device Storage tank is almost or completely Check salt level empty Blending has been set incorrectly Control valve is contaminated or defective CS = Customer services tel. All components subject to pressure in glass-fibrereinforced plastics · D06F Pressure reducing valve Noise protected pressure reducing valve with setting scale. Maximum inlet pressure 16 bar, with brass filter bowl 25 bar, outlet pressure range 1. 0 bar A = With clear filter bowl up to 40 °C / 16 bar B = With brass filter bowl up to 70 °C / 25 bar F76S Fine filter, reverse rinsable AA = With clear filter bowl AAM= With red bronze filter bowl OFV10S-A Bypass valve insert if a pressure scourer is applicated it is neccessary to fit a bypass valve insert into the bypass valve. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HONEYWELL KALTECSOFT KS10S




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual HONEYWELL KALTECSOFT KS10S will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.